| Literature DB >> 34003818 |
Daria Chmielewska1, Grzegorz Sobota2, Paweł Dolibog3, Patrycja Dolibog3, Agnieszka Opala-Berdzik4.
Abstract
The primary aim of the study was to assess intraday and interday reliability of surface electromyography (sEMG) reflex activity of the pelvic floor muscles during synchronous whole-body vibration (S-WBV) of two intensities (30Hz/2mm; 40Hz/4mm) using band-stop filter and high-pass filter signal processing. The secondary aim of the study was to assess intraday and interday (test-retest) reliability of sEMG obtained from maximal voluntary contraction (MVC) test. We evaluated the intraday reliability of sEMG recordings obtained during sessions 1 and 2 performed on the same day. The sessions consisting of maximal voluntary pelvic floor muscle contraction and synchronous vibration sets with 1-hour rest in-between sessions 1 and 2 in healthy nulliparous women. The next intraday reliability was evaluated between the results of sessions 3 and 4 performed on the same day but followed at an interval of 4 weeks. to include the entire menstrual cycle. The interday reliability was determined based on the results of sessions 1 and 3 using the intraclass correlation coefficient (ICC 3,3). The intraday ICCs for band-stop filtered mean and median sEMG frequency and mean normalized sEMGRMS amplitude of the 30Hz/2mm (ICC = 0.89-0.99) and 40Hz/4mm vibration (ICC = 0.95-0.99) indicated substantial reproducibility. The intraday reliability of high-pass filter at 100-450Hz for these parameters was also substantial (30Hz/2mm ICC of 0.92 to 0.98; 40Hz/4mm ICC of 0.88 to 0.98). The interday reliability (session 1 vs. session 3) of the mean normalized sEMGRMS amplitude for band-stop filtered means of 40 Hz/4mm and 30Hz/2mm vibration recordings was substantial (ICC = 0.82 and 0.93). However, ICCs of the mean and median frequency were indicative of fair reliability (ICC of 0.43 to 0.59). The interday reliability of mean normalized sEMGRMS amplitude for high-pass filter at 100-450Hz was substantial (30Hz/2mm ICC of 0.90; 40Hz/4mm ICC of 0.73) for the 30Hz/2mm S-WBV and moderate (ICC = 0.73) for the 40/4mm S-WBV. The ICCs for mean and median sEMG frequency ICCs indicated slight to fair reproducibility (ICC of 0.16 to 0.56). The intraday reliability of the strongest MVC contraction and average MVC turned out substantial (ICC = 0.91-0.98). The interday reliability coefficients of the strongest MVC contraction and average MVCs were 0.91 and 0.82, respectively. Concluded, the intraday reliability proved satisfactory for all variables; however, the interday comparison showed sufficient ICC levels only for the mean amplitude. We therefore recommend this parameter should be used when analyzing PFM sEMG recorded during vibration. ICCs of the mean and median frequency for both signal processing methods were indicative of insufficient reliability and did not reach the threshold for usefulness. Our study showed similar reliability of PFM sEMG during S-WBV in case of the two filtering methods used.Entities:
Year: 2021 PMID: 34003818 PMCID: PMC8130969 DOI: 10.1371/journal.pone.0251265
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Characteristics of study participants.
| Characteristics | group n = 8 | ||
|---|---|---|---|
| mean ± SD or n (%) | min. | max | |
| Age [years] | 24.2 ± 2.9 | 20 | 30 |
| Body weight [kg] | 64.1 ± 10.2 | 45 | 75 |
| Height [cm] | 167 ± 4.6 | 157.5 | 176 |
| BMI [kg/m2] | 22.8 ± 2.8 | 18.4 | 26.6 |
| Current oral contraception users | |||
| No | 5 (62.5%) | ||
| Yes | 3 (37.5%) | ||
Fig 1Study procedure of surface electromyography (sEMG) of pelvic floor muscles (PFM) which was performed to analyze intraclass correlation coefficients.
Filled arrows indicate intraday reliability (session 1 vs. session 2; session 3 vs. session 4), striped arrow indicates interday reliability (session 1 vs. session 3), MVC–maximal voluntary contraction; S-WBV–synchronous whole body vibration.
Fig 2Mean values with standard errors and standard deviations of sEMG parameters acquired from sEMG recordings using vibration of two intensities.
1; 2; 3; 4 -number of session.
Band-stop filtered and high-pass filtered intraday reliability of 30Hz/2mm—whole body vibration sEMG signals from the pelvic floor muscle.
| Parameter (unit) | session | mean (±SD) | ICC | 95% CI | CV (%) | SEM | MD | CC(r2); p* value |
|---|---|---|---|---|---|---|---|---|
| S-WBV 30Hz/2mm | band-stop filter | |||||||
| MNF(Hz) | 1 | 86.81 (±23.05) | 0.99 | 0.98–1 | 3.38 | 2.73 | 7.54 | 0.99; 0.000001 |
| 2 | 84.86 (±19.97) | |||||||
| MNF(Hz) | 3 | 89.38 (±26.24) | 0.99 | 0.98–1 | 3.15 | 3.01 | 8.31 | 0.99; 0.00001 |
| 4 | 89.3 (±29.85) | |||||||
| MDF(Hz) | 1 | 69.66 (±18.39) | 0.99 | 0.97–1 | 3.99 | 2.72 | 7.52 | 0.97; 0.000007 |
| 2 | 68.21 (±15.82) | |||||||
| MDF(Hz) | 3 | 72.08 (±24.45) | 0.98 | 0.97–1 | 5.22 | 4.02 | 11.12 | 0.99; 0.000001 |
| 4 | 72.37 (±29.69) | |||||||
| EMG RMS (%MVC) | 1 | 20.32 (±8.15) | 0.89 | 0.74–1 | 15.62 | 3.24 | 8.96 | 0.69; 0.01 |
| 2 | 19.21 (±6.34) | |||||||
| EMG RMS (%MVC) | 3 | 20.13 (±8.15) | 0.98 | 0.95–1 | 11.39 | 2.02 | 5.57 | 0.96; 0.00001 |
| 4 | 22.28 (±10.35) | |||||||
| MNF(Hz) | 1 | 189.78 (±15.18) | 0.94 | 0.85–1 | 2.52 | 5.07 | 14.01 | 0.78; 0.003 |
| 2 | 189.03 (±14.36) | |||||||
| MNF(Hz) | 3 | 189.87 (±14.16) | 0.97 | 0.94–1 | 2.12 | 3.58 | 9.90 | 0.98; 0.00001 |
| 4 | 193.13 (±18.75) | |||||||
| MDF(Hz) | 1 | 164.29 (±14.65) | 0.98 | 0.95–1 | 1.70 | 2.74 | 7.57 | 0.93; 0.0001 |
| 2 | 162.75 (±13.58) | |||||||
| MDF(Hz) | 3 | 165.46 (±13.25) | 0.96 | 0.92–1 | 2.63 | 4.04 | 11.17 | 0.96; 0.00001 |
| 4 | 168.62 (±18.15) | |||||||
| EMG RMS (%MVC) | 1 | 10.23 (±4.29) | 0.92 | 0.81–1 | 15.93 | 1.45 | 4.01 | 0.80; 0.002 |
| 2 | 9.18 (±3.11) | |||||||
| EMG RMS (%MVC) | 3 | 10.14 (±3.59) | 0.95 | 0.88–1 | 12.23 | 1.21 | 3.35 | 0.83; 0.001 |
| 4 | 11.02 (±4.16) | |||||||
Note: p*CC with significance
Abbreviations: ICC, interclass correlation coefficient model 3,3 (for three repetitions of sEMG recording); CI, confidence interval; CV, coefficient of variation; SEM, standard error of measurement (units as for measurement); MD, minimal differences (units as for measurement); CC, coefficient of correlations with significance (p value); EMG, surface electromyography; MNF, mean frequency; MDF, median frequency; EMG RMS %MVC, the mean of root mean square of surface electromyography normalized to MVC.
Band-stop filtered and high-pass filtered intraday reliability of 40Hz/4mm—whole body vibration sEMG signals from the pelvic floor muscle.
| Parameter (unit) | session | mean (±SD) | ICC | 95% CI | CV (%) | SEM | MD | CC (r2); p* value |
|---|---|---|---|---|---|---|---|---|
| S-WBV 40Hz/4mm | band-stop filter | |||||||
| MNF(Hz) | 1 | 92.43 (±22.79) | 0.99 | 0.98–1 | 4.19 | 3.25 | 8.97 | 0.97; 0.00007 |
| 2 | 89.20 (±25.06) | |||||||
| MNF(Hz) | 3 | 91.76 (±21.94) | 0.99 | 0.98–1 | 2.81 | 2.73 | 7.55 | 0.99; 0.00002 |
| 4 | 91.62 (±25.47) | |||||||
| MDF(Hz) | 1 | 74.66 (±19.70) | 0.97 | 0.94–1 | 6.42 | 4.70 | 12.99 | 0.91; 0.0002 |
| 2 | 72.25 (±21.64) | |||||||
| MDF(Hz) | 3 | 76.04 (±21.06) | 0.99 | 0.98–1 | 3.32 | 2.54 | 7.03 | 0.98;0.0001 |
| 4 | 75.04 (±23.93) | |||||||
| EMG RMS (%MVC) | 1 | 33.87 (±14.09) | 0.95 | 0.89–1 | 11.75 | 3.66 | 10.11 | 0.88; 0.005 |
| 2 | 31.42 (±11.29) | |||||||
| EMG RMS (%MVC) | 3 | 29,89 (±10.69) | 0.97 | 0.93–1 | 8.97 | 2.74 | 7.57 | 0.89; 0.0004 |
| 4 | 31.28 (±11.75) | |||||||
| MNF(Hz) | 1 | 186.19 (±15.96) | 0.97 | 0.94–1 | 1.90 | 3.78 | 10.46 | 0.91; 0.0002 |
| 2 | 186.26 (±17.90) | |||||||
| MNF(Hz) | 3 | 187.56 (±15.13) | 0.92 | 0.83–1 | 4.11 | 7.51 | 20.74 | 0.92; 0.0001 |
| 4 | 192.36 (±24.22 | |||||||
| MDF(Hz) | 1 | 161.97 (±15.58) | 0.98 | 0.96–1 | 1.94 | 3.27 | 9.03 | 0.95; 0.00004 |
| 2 | 163.12 (±18.11) | |||||||
| MDF(Hz) | 3 | 164.37 (±13.89) | 0.88 | 0.74–1 | 5.52 | 9.15 | 25.27 | 0.90; 0.0003 |
| 4 | 169.21 (±25.36) | |||||||
| EMG RMS (%MVC) | 1 | 18.20 (±9.71) | 0.92 | 0.82–1 | 22.89 | 3.20 | 8.84 | 0.82; 0.002 |
| 2 | 14.92 (±6.86) | |||||||
| EMG RMS (%MVC) | 3 | 14.25 (±4.93) | 0.97 | 0.94–1 | 8.42 | 1.22 | 3.38 | 0.92; 0.0002 |
| 4 | 14.88 (±5.71) | |||||||
Note: p*CC with significance
Abbreviations: ICC, interclass correlation coefficient model 3,3 (for three repetitions of sEMG recording); CI, confidence interval; CV, coefficient of variation; SEM, standard error of measurement (units as for measurement); MD, minimal differences (units as for measurement); CC, coefficient of correlations with significance (p value); EMG, surface electromyography; MNF, mean frequency; MDF, median frequency; EMG RMS %MVC, the mean of root mean square of surface electromyography normalized to MVC.
Band-stop filtered and high-pass filtered interday reliability of 30Hz/2mm and 40Hz/4mm—whole body vibration sEMG signals from the pelvic floor muscle.
| Parameter (unit)/ intensity of vibration | session | mean (±SD) | ICC | 95% CI | CV (%) | SEM | MD | CC (r2); p value |
|---|---|---|---|---|---|---|---|---|
| band-stop filter | ||||||||
| MNF(Hz)/ 30Hz/2mm | 1 | 86.81 (±23.5) | 0.59 | 0.14–1 | 20.10 | 18.83 | 52.03 | 0.18; 0.2 |
| 3 | 89.38 (±26.24) | |||||||
| MNF(Hz)/ 40Hz/4mm | 1 | 92.43 (±22.79) | 0.53 | 0.06–1 | 19.14 | 18.91 | 52.26 | 0.13; 0.4 |
| 3 | 91.76 (±21.94 | |||||||
| MDF(Hz)/ 30Hz/2mm | 1 | 69.67 (±18.39) | 0.55 | 0.06–1 | 17.10 | 16.7 | 46.12 | 0.15; 0.3 |
| 3 | 72.08 (±24.45) | |||||||
| MDF(Hz)/ 40Hz/4mm | 1 | 74.67 (±19.70) | 0.43 | 0.02–0.99 | 22.28 | 18.00 | 49.76 | 0.11; 0.4 |
| 3 | 76.04 (±21.06) | |||||||
| EMG RMS %MVC/ 30Hz/2mm | 1 | 20.26 (±8.22) | 0.93 | 0.84–1 | 13.83 | 2.98 | 8.23 | 0.75; 0.005* |
| 3 | 20.06 (±8.23) | |||||||
| EMG RMS %MVC/ 40Hz/4mm | 1 | 33.87 (±14.09) | 0.82 | 0.59–1 | 22.27 | 6.96 | 19.23 | 0.55; 0.03* |
| 3 | 29.89 (±10.69) | |||||||
| MNF(Hz)/ 30Hz/2mm | 1 | 189.78 (±15.18) | 0.56 | 0.08–1 | 5.66 | 11.49 | 31.75 | 0.15; 0.3 |
| 3 | 189.87 (±14.16) | |||||||
| MNF(Hz)/ 40Hz/4mm | 1 | 186.19 (±15.96) | 0.35 | 0–0.96 | 6.91 | 13.78 | 38.07 | 0.04; 0.6 |
| 3 | 187.56 (±15.13) | |||||||
| MDF(Hz)/ 30Hz/2mm | 1 | 164.29 (±14.65) | 0.24 | 0–0.89 | 7.37 | 12.96 | 35.82 | 0.02; 0.7 |
| 3 | 165.46 (±13.25 | |||||||
| MDF(Hz)/ 40Hz/4mm | 1 | 161.97 (±15.58) | 0.16 | 0–0.83 | 8.14 | 14.09 | 38.93 | 0.01; 0.8 |
| 3 | 164.37 (±13.89) | |||||||
| EMG RMS %MVC/ 30Hz/2mm | 1 | 10.24 (±4.29) | 0.90 | 0.77–1 | 15.56 | 1.69 | 4.68 | 0.65; 0.01* |
| 3 | 10.14 (±3.59) | |||||||
| EMG RMS %MVC/ 40Hz/4mm | 1 | 18.19 (±9.71) | 0.73 | 0.41–1 | 33.79 | 5.04 | 13.94 | 0.50; 0.04* |
| 3 | 14.25 (±4.93) | |||||||
Note: p*CC with significance
Abbreviations: ICC, interclass correlation coefficient model 3,3 (for three repetitions of sEMG recording); CI, confidence interval; CV, coefficient of variation; SEM, standard error of measurement (units as for measurement); MD, minimal differences (units as for measurement); CC, coefficient of correlations with significance (p value); EMG, surface electromyography; MNF, mean frequency; MDF, median frequency; EMG RMS %MVC, the mean of root mean square of surface electromyography normalized to MVC.
Intraday and interday reliability of pelvic floor muscle MVC.
| Parameter (unit) | session | mean (±SD) | ICC | 95% CI | CV (%) | SEM | MD | CC (r2); p value |
|---|---|---|---|---|---|---|---|---|
| MVCB (μV) | 1 | 49.98 (±15.41) | 0.83 | 0.62–1 | 11 | 5.71 | 15.78 | 0.73; 0.007 |
| 2 | 52.48 (±12.69) | |||||||
| MVCB (μV) | 3 | 55.71 (±19.34) | 0.98 | 0.93–1 | 9.94 | 3.32 | 9.17 | 0.94; 0.0006 |
| 4 | 49.74 (±18.68) | |||||||
| MVCB (μV) | 1 | 49.98 (±15.41 | 0.84 | 0.63–1 | 14.52 | 6.97 | 19.26 | 0.74; 0.005 |
| 3 | 55.71 (±19.34) | |||||||
| MVCA (μV) | 1 | 45.71 (14.17) | 0.88–1 | 8.53 | 4.15 | 11.46 | 0.83; 0.001 | |
| 2 | 46.65 (13.14) | |||||||
| MVCA (μV) | 3 | 53.40 (19.85) | 0.88–1 | 0.14 | 5.73 | 15.83 | 0.84; 0.001 | |
| 4 | 46.21 (16.91) | |||||||
| MVCA (μV) | 1 | 45.71 (14.17) | 0.58–1 | 21.21 | 9.61 | 26.55 | 0.53; 0.04 | |
| 3 | 53.40 (19.85) |
Note: p*CC with significance
Abbreviations: ICC, interclass correlation coefficient model 3,1 (for the greatest value of three MVC trials)
*ICC, interclass correlation coefficient model 3,3 (for three trials of MVC); CI, confidence interval; CV, coefficient of variation; SEM, standard error of measurement (units as for measurement); MD, minimal differences (units as for measurement); CC, coefficient of correlations with significance (p value); MVCB the greatest value of the three trials of maximal voluntary contraction, MVCA average maximal voluntary contraction (mean amplitude of three MVC trials).