PURPOSE: To evaluate the intra and interobserver reproducibility of a new goniometric method for evaluating the isolated passive range of motion of the glenohumeral joint in an outpatient setting.Entities:
Keywords: Glenohumeral joint; Goniometric; Range of motion; Shoulder
Year: 2021 PMID: 33993351 PMCID: PMC8124032 DOI: 10.1186/s40634-021-00352-z
Source DB: PubMed Journal: J Exp Orthop ISSN: 2197-1153
Fig. 1The Glenohumeral ROM Assessment with Scapular Pinch (GRASP) method. For a detailed description of each image see text
Intra and interobserver Intraclass Correlation Coefficients (ICC) with 95% confidence intervals (95% Conf. Int) for the measurements of isolated glenohumeral passive abduction (GH-AB) ROM, passive external rotation GH-(ER) and internal rotation (GH-IR) with the arm at 45º of abduction; and for full shoulder (FS) passive abduction (FS-AB) ROM, passive external rotation (FS-ER) and passive internal rotation (FS-IR) with the arm at 45º of abduction are also presented. ICC values below 0.5 (considered poor reproducibility) are shaded in dark grey, values between 0.5 and 0.75 (moderate reproducibility) are shaded in light grey,and values over 0,75 (good reproducibility) are left white
| Intraobserver | Interobserver | |||
|---|---|---|---|---|
| Variable | ICC | 95% Conf. Int | ICC | 95% Conf. Int |
| GH-PAB | 0.84 | 0.75–0.91 | 0.86 | 0.77–0.92 |
| GH-PER | 0.63 | 0.52–0.80 | 0.68 | 0.52–0.80 |
| GH_PIR | 0.61 | 0.44–0.75 | 0.62 | 0.45–0.76 |
| FS-PAB | 0.81 | 0.70–0.89 | 0.83 | 0.72–0.90 |
| FS-PER | 0.80 | 0.68–0,88 | 0.63 | 0.47–0,77 |
| FS-PIR | 0.57 | 0.41–0.73 | 0.53 | 0.36–0.70 |
Fig. 2The Bland–Altman plots for intraobserver (a, b, c) and interobserver (d, e, f) reproducibility for glenohumeral passive abduction (GH-PAS), external rotation (GH-PER) and internal rotation (GH-PIR)