Variabilities in measurement of coronary arterial dimensions resulting from variations in cineframe selection.

J H Reiber1, P van Eldik-Helleman, N Visser-Akkerman, C J Kooijman, P W Serruys.   

Abstract

To quantitatively analyze a coronary arterial segment from a cineangiogram, an end-diastolic or neighboring cineframe is usually selected, such that a possibly existing coronary lesion is visualized optimally, as judged by the cardiologist. However, different cardiologists may select different (although usually neighboring) frames, even when following the same selection criteria. It is also possible that the frames are selected from different cardiac cycles. In this study the effects of such phase shifts on the reproducibility of the quantitative measurements were studied. In a total of 38 consecutive patient films obtained at a filmspeed of 25 frames/sec, the frame 0 demonstrating the severity of a lesion optimally, as judged by a senior cardiologist, the three preceding frames, the three following frames and one frame exactly one cycle prior to or following frame 0 were selected; frame 0 was always chosen in the end-diastolic phase of the cardiac cycle. In each film one coronary arterial segment with a focal lesion was analyzed quantitatively in these eight frames with the Cardiovascular Angiography Analysis System (CAAS). No significant differences were found in the mean difference and the standard deviations of the differences (variabilities) in the obstruction diameter, interpolated reference diameter, percent diameter stenosis, extent of the obstruction and area of atherosclerotic plaque obtained in the various frames with respect to frame 0. Therefore, it may be concluded that the selection of a cineframe for quantitative analysis in the end-diastolic phase of the cardiac cycle is not very critical; in other words, the obstruction measurements are not time-dependent for frames in the end-diastolic phase.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3396064     DOI: 10.1002/ccd.1810140402

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  11 in total

1.  Elimination of variable vasomotor tone in studies with repeated quantitative coronary angiography.

Authors:  S Jost; W Rafflenbeul; G H Reil; H J Trappe; D Gulba; H Hecker; U Gerhardt; I Knop
Journal:  Int J Card Imaging       Date:  1990

2.  Morphometry versus densitometry--a comparison by use of casts of human coronary arteries.

Authors:  P A Doriot; C Suilen; N Guggenheim; P A Dorsaz; F Chappuis; W Rutishauser
Journal:  Int J Card Imaging       Date:  1992

3.  Vasodilatory effects of nisoldipine on coronary arteries--correlation with plasma levels.

Authors:  S Jost; W Rafflenbeul; B Mogwitz; D Gulba; H Hecker; P R Lichtlen
Journal:  Cardiovasc Drugs Ther       Date:  1990-02       Impact factor: 3.727

4.  Comparison of QCA systems.

Authors:  U Dietz; H J Rupprecht; R Brennecke; H P Fritsch; J Woltmann; S Blankenberg; J Meyer
Journal:  Int J Card Imaging       Date:  1997-08

5.  Local paclitaxel induces late lumen enlargement in coronary arteries after balloon angioplasty.

Authors:  Franz X Kleber; Antonia Schulz; Matthias Waliszewski; Telse Hauschild; Michael Böhm; Ulrich Dietz; Bodo Cremers; Bruno Scheller; Yvonne P Clever
Journal:  Clin Res Cardiol       Date:  2014-10-28       Impact factor: 5.460

6.  The influence of image enhancement and reconstruction on quantitative coronary arteriography.

Authors:  P M van der Zwet; J H Reiber
Journal:  Int J Card Imaging       Date:  1995-12

7.  Shortening the stent length reduces restenosis with bare metal stents: matched pair comparison of short stenting and conventional stenting.

Authors:  U Dietz; N Holz; C Dauer; H Lambertz
Journal:  Heart       Date:  2005-05-09       Impact factor: 5.994

8.  Combining short stent implantation and drug-eluting stenting for routine use yields a low restenosis rate.

Authors:  Ulrich Dietz; Cheryl Dauer; Heinz Lambertz
Journal:  Exp Clin Cardiol       Date:  2006

9.  Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system.

Authors:  W Desmet; J L Willems; M Vrolix; J van Lierde; G Byttebier; J Piessens
Journal:  Int J Card Imaging       Date:  1993-12

10.  Combining short stent implantation and drug-eluting stenting for routine use yields a low restenosis rate.

Authors:  Ulrich Dietz; Cheryl Dauer; Heinz Lambertz
Journal:  Curr Control Trials Cardiovasc Med       Date:  2005-12-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.