| Literature DB >> 33956194 |
Fabio Cherubini1, Antonio Cristiano1,2, Alessandra Valentini1,3, Sergio Bernardini1,3,4, Marzia Nuccetelli5,6.
Abstract
OBJECTIVE ANDEntities:
Keywords: COVID-19; Circulating calprotectin; Inflammatory marker; Laboratory medicine; SARS-CoV-2
Mesh:
Substances:
Year: 2021 PMID: 33956194 PMCID: PMC8101083 DOI: 10.1007/s00011-021-01465-y
Source DB: PubMed Journal: Inflamm Res ISSN: 1023-3830 Impact factor: 4.575
Median and mean circulating calprotectin concentration. Serum calprotectin was detected on negative RT-PCR controls and positive RT-PCR patients; plasma calprotectin was detected on healthy controls, negative RT-PCR patients and positive RT-PCR patients
| Patients’ cohort | Mean [CLP] | Std. deviation | Median [CLP] | |
|---|---|---|---|---|
| Serum | Negative RT-PCR controls ( | 176.9 ng/mL | ± 110.7 ng/mL | 143.9 ng/mL (13.91–508.4) |
Positive RT-PCR patients ( | 439.9 ng/mL | ± 504.0 ng/mL | 292.7 ng/mL (19.13–3642) | |
| Plasma | Negative controls ( | 45.36 ng/mL | ± 31.13 ng/mL | 32.87 ng/mL (14.00–152.20) |
| Negative RT-PCR patients ( | 177.2 ng/mL | ± 201.5 ng/mL | 104.8 ng/mL (32.17–1022) | |
Positive RT-PCR patients ( | 352.3 ng/mL | ± 371.6 ng/mL | 222.7 ng/mL (48.35–1621) |
Fig. 1Serum calprotectin concentrations in the negative SARS-CoV-2 RT-PCR control group and in the positive SARS-CoV-2 RT-PCR hospitalized COVID-19 patient group
Fig. 2Plasma calprotectin concentrations in the healthy negative control group, in the negative SARS-CoV-2 RT-PCR patient group and in the positive SARS-CoV-2 RT-PCR patient group
Plasma calprotectin sensitivity, specificity, cutoff and AUC values obtained in the different group comparisons (healthy controls vs negative RT-PCR patients; healthy controls vs positive RT-PCR patients; negative RT-PCR patients vs positive RT-PCR patients)
| Negative controls vs negative RT-PCR patients | Negative controls vs positive RT-PCR patients | Negative RT-PCR patients vs positive RT-PCR patients | |
|---|---|---|---|
| Sensitivity | 83.05% | 92.31% | 70.77% |
| Specificity | 80.28% | 94.37% | 69.49% |
| Cutoff | > 76.45 ng/mL | > 93.04 ng/mL | > 131.3 ng/mL |
Area under ROC curve (AUC); 95% confidence interval | 0.8872; 0.8328–0.9416 | 0.9684; 0.9443–0.9924 | 0.7257; 0.6358–0.8156 |
Fig. 3Plasma calprotectin ROC curves. Panel A shows the comparison between healthy negative control group and negative SARS-CoV-2 RT-PCR patient group (AUC = 0.8872, p < 0.0001); panel B shows the comparison between healthy negative control group and positive SARS-CoV-2 RT-PCR patient group (AUC = 0.9684, p < 0.0001); panel C shows the comparison between negative SARS-CoV-2 RT-PCR patient group and positive SARS-CoV-2 RT-PCR patient group (AUC = 0.7257, p < 0.0001)