Literature DB >> 33946325

Estimation of 3D Body Center of Mass Acceleration and Instantaneous Velocity from a Wearable Inertial Sensor Network in Transfemoral Amputee Gait: A Case Study.

Emeline Simonetti1,2,3, Elena Bergamini3, Giuseppe Vannozzi3, Joseph Bascou1,2, Hélène Pillet2.   

Abstract

The analysis of the body center of mass (BCoM) 3D kinematics provides insights on crucial aspects of locomotion, especially in populations with gait impairment such as people with amputation. In this paper, a wearable framework based on the use of different magneto-inertial measurement unit (MIMU) networks is proposed to obtain both BCoM acceleration and velocity. The proposed framework was validated as a proof of concept in one transfemoral amputee against data from force plates (acceleration) and an optoelectronic system (acceleration and velocity). The impact in terms of estimation accuracy when using a sensor network rather than a single MIMU at trunk level was also investigated. The estimated velocity and acceleration reached a strong agreement (ρ > 0.89) and good accuracy compared to reference data (normalized root mean square error (NRMSE) < 13.7%) in the anteroposterior and vertical directions when using three MIMUs on the trunk and both shanks and in all three directions when adding MIMUs on both thighs (ρ > 0.89, NRMSE ≤ 14.0% in the mediolateral direction). Conversely, only the vertical component of the BCoM kinematics was accurately captured when considering a single MIMU. These results suggest that inertial sensor networks may represent a valid alternative to laboratory-based instruments for 3D BCoM kinematics quantification in lower-limb amputees.

Entities:  

Keywords:  CoM; MIMU; gait analysis; kinematics; locomotion; lower-limb amputation; prosthesis; sensor network; wearable sensors

Mesh:

Year:  2021        PMID: 33946325     DOI: 10.3390/s21093129

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  47 in total

1.  Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors.

Authors:  Hooman Dejnabadi; Brigitte M Jolles; Emilio Casanova; Pascal Fua; Kamiar Aminian
Journal:  IEEE Trans Biomed Eng       Date:  2006-07       Impact factor: 4.538

2.  A spot check for assessing static orientation consistency of inertial and magnetic sensing units.

Authors:  Pietro Picerno; Andrea Cereatti; Aurelio Cappozzo
Journal:  Gait Posture       Date:  2011-01-11       Impact factor: 2.840

3.  A simplified marker set to define the center of mass for stability analysis in dynamic situations.

Authors:  R Tisserand; T Robert; R Dumas; L Chèze
Journal:  Gait Posture       Date:  2016-05-06       Impact factor: 2.840

4.  Simultaneous positive and negative external mechanical work in human walking.

Authors:  J Maxwell Donelan; Rodger Kram; Arthur D Kuo
Journal:  J Biomech       Date:  2002-01       Impact factor: 2.712

5.  Portable Gait Lab: Estimating 3D GRF Using a Pelvis IMU in a Foot IMU Defined Frame.

Authors:  Mohamed Irfan Mohamed Refai; Bert-Jan F van Beijnum; Jaap H Buurke; Peter H Veltink
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2020-04-20       Impact factor: 3.802

6.  Stepping asymmetry among individuals with unilateral transtibial limb loss might be functional in terms of gait stability.

Authors:  Laura Hak; Jaap H van Dieën; Peter van der Wurff; Han Houdijk
Journal:  Phys Ther       Date:  2014-06-05

7.  Comparison of gait variability and symmetry in trained individuals with transtibial and transfemoral limb loss.

Authors:  Hilal Keklicek; Elif Kirdi; Ali Yalcin; Semra Topuz; Ozlem Ulger; Fatih Erbahceci; Gul Sener
Journal:  J Orthop Surg (Hong Kong)       Date:  2019 Jan-Apr       Impact factor: 1.118

8.  Estimation of Center of Mass Trajectory using Wearable Sensors during Golf Swing.

Authors:  Bijan Najafi; Jacqueline Lee-Eng; James S Wrobel; Ruben Goebel
Journal:  J Sports Sci Med       Date:  2015-05-08       Impact factor: 2.988

9.  IMU: inertial sensing of vertical CoM movement.

Authors:  Patrick Esser; Helen Dawes; Johnny Collett; Ken Howells
Journal:  J Biomech       Date:  2009-05-13       Impact factor: 2.712

Review 10.  Estimating three-dimensional orientation of human body parts by inertial/magnetic sensing.

Authors:  Angelo Maria Sabatini
Journal:  Sensors (Basel)       Date:  2011-01-26       Impact factor: 3.576

View more
  3 in total

1.  Identifying the Effects of Age and Speed on Whole-Body Gait Symmetry by Using a Single Wearable Sensor.

Authors:  Antonino Casabona; Maria Stella Valle; Giulia Rita Agata Mangano; Matteo Cioni
Journal:  Sensors (Basel)       Date:  2022-07-02       Impact factor: 3.847

2.  Running-Induced Fatigue Changes the Structure of Motor Variability in Novice Runners.

Authors:  Felix Möhler; Cagla Fadillioglu; Lucia Scheffler; Hermann Müller; Thorsten Stein
Journal:  Biology (Basel)       Date:  2022-06-20

3.  Use of a Single Wearable Sensor to Evaluate the Effects of Gait and Pelvis Asymmetries on the Components of the Timed Up and Go Test, in Persons with Unilateral Lower Limb Amputation.

Authors:  Maria Stella Valle; Antonino Casabona; Ilenia Sapienza; Luca Laudani; Alessandro Vagnini; Sara Lanza; Matteo Cioni
Journal:  Sensors (Basel)       Date:  2021-12-24       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.