Literature DB >> 33938119

Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study.

Burak Yilmaz1,2,3, Gülce Çakmak4, Burcu Batak5, William M Johnston3.   

Abstract

BACKGROUND: Limited information is available regarding the removal torque values (RTVs) of screws of different abutment materials when used with different implants.
PURPOSE: To evaluate the effect of implant type and abutment material (zirconia; Zir and titanium; Ti) on the RTVs of abutment screws after cyclic loading.
MATERIALS AND METHODS: Internal conical connection implants (CC, OsseoSpeed TX) and modified internal conical connection implants (MCC, OsseoSpeed EV) (n = 10) were clamped in resin dies. Zir and Ti (N = 20) custom abutments were tightened to implants (20 Ncm for CC and 25 Ncm for MCC) as specified by their manufacturers. The abutments were cyclically loaded by using a sequentially increased loading protocol; 2-million cycles under 100 N, 3-million cycles under 200 N, and 2-million cycles under 300 N loads with 2 Hz. After 7 million cycles, RTVs (Ncm) were measured by using a torque gauge. The data were analyzed with ANOVA by using the restricted maximum likelihood estimation method. Tukey-Kramer adjustment was used for any significant interaction of implant-abutment pairs (α = 0.05).
RESULTS: Two CC implants, 1 with Ti and 1 with Zir abutment, fractured during cyclic loading (under 300 N loads within the 6th and 7th million cycles) and discarded for statistical analysis. Only implant type had a significant effect on RTVs (p <0.001). Screws of Ti abutments on MCC implants had significantly higher RTVs than the screws of Ti (p = 0.003) and Zir (p = 0.005) abutments on CC implants.
CONCLUSIONS: Implant type affected the RTVs, however, the RTVs were higher than the initial torque values for all groups. Screws of Ti abutments on implant, which required greater initial torque values had higher RTVs than the screws of Ti and Zir abutments on the implant that required smaller initial torque values. RTVs were similar for Zir and Ti abutment screws within each implant type.
© 2021 Wiley Periodicals LLC.

Entities:  

Keywords:  abutment; internal conical connection; removal torque; screw; zirconia

Mesh:

Substances:

Year:  2021        PMID: 33938119     DOI: 10.1111/cid.13001

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  2 in total

1.  The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload.

Authors:  Shahad Mohammmed Altuwaijri; Hanan Nejer Alotaibi; Talal Mughaileth Alnassar
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

2.  Monolithic zirconia single tooth implant-supported restorations with CAD/CAM titanium abutments in the posterior region: A 1-year prospective case series study.

Authors:  Vincent J J Donker; Gerry M Raghoebar; Charlotte Jensen-Louwerse; Arjan Vissink; Henny J A Meijer
Journal:  Clin Implant Dent Relat Res       Date:  2022-01-24       Impact factor: 4.259

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.