Literature DB >> 33927204

A magnetoencephalography dataset for motor and cognitive imagery-based brain-computer interface.

Dheeraj Rathee1, Haider Raza2, Sujit Roy3, Girijesh Prasad3.   

Abstract

Recent advancements in magnetoencephalography (MEG)-based brain-computer interfaces (BCIs) have shown great potential. However, the performance of current MEG-BCI systems is still inadequate and one of the main reasons for this is the unavailability of open-source MEG-BCI datasets. MEG systems are expensive and hence MEG datasets are not readily available for researchers to develop effective and efficient BCI-related signal processing algorithms. In this work, we release a 306-channel MEG-BCI data recorded at 1KHz sampling frequency during four mental imagery tasks (i.e. hand imagery, feet imagery, subtraction imagery, and word generation imagery). The dataset contains two sessions of MEG recordings performed on separate days from 17 healthy participants using a typical BCI imagery paradigm. The current dataset will be the only publicly available MEG imagery BCI dataset as per our knowledge. The dataset can be used by the scientific community towards the development of novel pattern recognition machine learning methods to detect brain activities related to motor imagery and cognitive imagery tasks using MEG signals.

Entities:  

Mesh:

Year:  2021        PMID: 33927204      PMCID: PMC8085139          DOI: 10.1038/s41597-021-00899-7

Source DB:  PubMed          Journal:  Sci Data        ISSN: 2052-4463            Impact factor:   6.444


Background & Summary

Mental imagery activities such as imagination of limb movement or mathematical calculation induce explicit and predictive patterns of brain activity that can be detected using electroencephalography (EEG) or magnetoencephalography (MEG)[1]. One of the most prominent brain patterns is event-related desynchronization/synchronization (ERD/ERS) of brainwaves in the alpha (8–13 Hz) and beta (16–30 Hz) frequency bands during motor imagery tasks. Brain-computer interfaces (BCIs) can detect and translate these patterns into actions and thus, provide a potential medium for communication and rehabilitation for patients with severe neuromuscular impairment[2-4]. MI-based BCIs employed with neurofeedback training paradigms can induce brain plasticity and possibly contribute to the enhancement of motor rehabilitation for stoke patients[5-7], thus, may provide an alternative to conventional recovery methods e.g. physical practice[8] for these patients. While majority of the research to date has focused on EEG modality, MEG can also be useful towards developing effective BCI systems[9,10]. MEG has the advantage of recording brain activity across the whole scalp while maintaining much higher spatial and temporal resolution. In addition, compared to EEG, MEG allows detection of higher frequencies as magnetic fields are less attenuated by the head bone and tissue as compared to electric fields[11]. Though not portable, MEG-based BCIs are relevant for rehabilitation interventions. Regardless of great potential, MEG-based BCI systems still need significant improvement in terms of robust and efficient signal processing algorithms. A big constraint towards the development of novel algorithms or validating currently available BCI signal processing pipelines is lack of open source MEG-BCI datasets. As per our knowledge, there are no sizable datasets available currently. In this work, we publish an MEG-based BCI dataset recorded using a conventional BCI paradigm involving MI and cognitive imagery (CI) tasks. The dataset contains 1134 minutes of MEG recordings across 34 recording sessions of 17 healthy participants (two sessions for each participant recorded on different days), and 6,800 imagery trials. BCI interactions involved two MI (both hands and both feet imagination) and two CI (word generations and mathematical subtraction) states. On average, 66 minutes of MEG recordings and 400 imagery trials are available per participant. The dataset is one of the first MI- and CI-related MEG-based BCI datasets published to date and presents a significant step from existing datasets in terms of uniformity, state-of-the-art MEG system, number of participants and MEG channels.

Methods

Participants

The study involved recruitment of 20 healthy participants. However, data of three participants are excluded from the dataset due to quality issues. Thus, the current dataset consists of 17 participants including 14 males (82.35%) and 3 females (17.64%), wherein median age of participants is 28 years with minimum age 22 years and maximum age 40 years. Out of 17, 15 participants are right-handed and 2 participants are left-handed (by self reporting). Table 1 provides the demographic information of all the participants. The names of all participants have been hereby anonymised. The participants are identified only by their participant Ids i.e. ‘sub-1’ through ‘sub-20’. Ids of excluded participants are ‘sub-5’, ‘sub-8’ and ‘sub-10’.
Table 1

Demographic information of all the participants with participant ID, age, gender, experience with BCI, and dominant hand.

Participant IDAgeGenderExp with BCIDominant Hand
sub-137MYesL
sub-236MNoR
sub-323MNoR
sub-423FYesR
sub-632FNoR
sub-728MYesR
sub-932MNoR
sub-1123MNoR
sub-1229MYesR
sub-1326MNoR
sub-1430FNoL
sub-1524MYesR
sub-1636MNoR
sub-1727MNoR
sub-1840MNoR
sub-1922MNoR
sub-2023MNoR
Demographic information of all the participants with participant ID, age, gender, experience with BCI, and dominant hand. The experimental procedures were approved by the University Research Ethics Committee of the Ulster University, Northern Ireland, UK. All research procedures were carried out in accordance with approved institutional guidelines and regulations and guidelines of the Helsinki declaration. Prior to the data acquisition process, all participants were informed about the purpose and the procedures of the experiments and informed consenting procedure was followed wherein participants provided written consent to allow usage of their anonymised data for research purposes by other researchers. The participants had been screened for the absence of any psychiatric condition, any medications taken, and contraindications to MEG. Inclusion criteria were as follows: healthy individuals, age between 18 to 80 years (both inclusive), and no history of neurological, developmental or language deficits. Exclusion criteria were as follows: claustrophobic, pregnant or breastfeeding, body tattoos, metal or active body implants and on-going medications.

MEG data acquisition

MEG data were recorded with a 306-channel (102 magnetometers and 204 planar gradiometers) Elekta Neuromag system (Elekta Oy, Helsinki, Finland) located at the Northern Ireland Functional Brain Mapping (NIFBM) Facility of the Intelligent Systems Research Centre, Ulster University. Elekta Neuromag system (Elekta Oy, Helsinki, Finland) is installed with MaxShield system which is a high-performance magnetic shielding system designed and optimised for bioelectromagnetic measurements using Elekta Neuromag. The system consists of structurally optimal magnetically shielded room with internal active shielding. All the participants were screened for any metallic foreign substance e.g. jewelry, coins, keys or any other ferromagnetic material before entering the magnetically shielded room. The standard fiducial landmarks (left and right pre – auricular points and Nasion), five head position indicator (HPI) coils (placed over scalp), and the additional reference points over the scalp were digitized (Fastrak Polhemus system) to store information about the participant’s head position, orientation, and shape. In addition, ocular and cardiac activities were recorded with two sets of bipolar electro – oculogram (EOG) electrodes (horizontal – EOG and vertical – EOG) and one set of electrocardiogram (EKG) electrodes, respectively. Before starting the data acquisition, the complete procedure and the experimental paradigm were described to the participants. All recordings were made with participants seated on a comfortable chair approximately 80 cm away from the projector screen and in upright position of MEG scanner. The MEG signals were filtered at a bandwidth of 0.01–300 Hz (online) and sampled at the rate of 1 kHz during the acquisition itself. Continuous head position estimation was started after 20 s of raw data recording and kept running for rest of the acquisition period.

Experimental paradigm

Figure 1 presents the timing diagram of the BCI paradigm used for the data acquisition. Each trial starts with a rest period of 2 s followed by 5 s of imagery task period. The cue remains visible during the whole imagery task period. During the rest period, participants were asked to fixate on a red cross presented at the center of the screen. A randomly selected inter- trial – interval (ITI) of 1.5–2 s was presented after the imagery task period. The fixation point and the cue were displayed on a Panasonic projector with a screen resolution of 1024 × 768 and refresh rate of 60 Hz. MEG data were acquired over 2 sessions (each session on different days) using the same BCI paradigm. Each session consisted of 50 trials for each of the imagery tasks, thus includes a total of 200 trials. A break of 5 minute duration was provided in each session after completion of first 100 trials. The participants were kept seated during the break and asked to relax.
Fig. 1

Timing diagram of MEG-BCI paradigm. Each trial starts with a rest period of 2 s followed by 5 s of imagery task period.

Timing diagram of MEG-BCI paradigm. Each trial starts with a rest period of 2 s followed by 5 s of imagery task period. The experimental paradigm was designed to cover four mental imagery tasks: two related to MI i.e. both hands movement imagery, both feet movement imagery and two related to CI i.e. mathematical subtraction imagery and word generation imagery. During the MI-related tasks, participants imagined movement of both hands/both feet when the related cue appeared at the screen (i.e. during the task period). Similarly, for CI tasks, participants either subtracted two numbers presented as cue or generated words related to the English language alphabet appeared as cue. Triggers were recorded within the .fif files (Elekta Neuromag system) to mark the start of imagery period for each trial.

Data processing

The original MEG dataset was acquired from all 306 sensors (204 gradiometers and 102 magnetometers) during two different sessions for each participant and recorded as .fif files. As each session consists of two data files due to session break, for better handling of the data, we have merged these files to create one single .fif file for each session. Thus, there are two raw .fif data files for each participant (i.e. one for each session). Our aim here is to provide the BCI researchers least processed data to allow them with greater flexibility towards customising the processing pipeline. However, we have also processed the .fif file format to convert the data in an epoched format (.mat file) to be compatible for BCI related analysis. Each epoch (trial) is generated with time duration of 7000 ms i.e. 2000 ms (pre-stimulus) to 5000 ms (post-stimulus). The triggers are available in both BIDS and.mat formats, where the classes are defined as follows:- Class 1: Both Hand Imagery, Class 2: Both Feet Imagery, Class 3: Word generation Imagery, and Class 4: Subtraction Imagery and their associated triggers in the STIM channels are 4, 8, 16, and 32, respectively. A detailed description of the data file structure is presented in Section ‘Data Records’. The fieldTrip Toolbox[12] has been used in all data processing steps.

Data Records

The data acquired during the described experiment are freely accessible and may be downloaded from figshare[13], which is a general-purpose repository that makes research outputs available in a citable, shareable, and discover-able manner. It is worth to be noted that the data is available in two data formats i.e. MEG-BIDS format[14] (.fif) and MATLAB compatible (.mat) file at the repository. Figure 2 shows the structure of the data directory for MEG-BIDS format where only one participant data structure is illustrated to avoid repetition. The folder named ‘MEG_BIDS’ contain two files named ‘dataset_description.json’ and ‘participant.tsv’. Further, there are 17 sub-folders (one for each participant data), each having scan file ‘_scan.tsv’ and a sub-folder named ‘meg’. Each ‘meg’ folder contains five files i.e. ‘_coordsystem.json’, ‘_channels.tsv’, ‘_events.tsv’, ‘_meg.fif’, and ‘_meg.json’.
Fig. 2

The structure of BIDS format data directory, where MEG_BIDS is a root folder. Under MEG_BIDS folder, each participant has its data folder (e.g. sub–1 is for participant 1), where two sub-folders are given for Session 1 and Session 2 of data recording, each sub-folder has a meg folder, where all the required information is available and ‘.fif’ files contain the MEG recording.

The structure of BIDS format data directory, where MEG_BIDS is a root folder. Under MEG_BIDS folder, each participant has its data folder (e.g. sub–1 is for participant 1), where two sub-folders are given for Session 1 and Session 2 of data recording, each sub-folder has a meg folder, where all the required information is available and ‘.fif’ files contain the MEG recording. We have also provided data in Matlab compatible format and shared the script at GitHub as well to convert the MEG-BIDS format to .mat file format. The root database folder (MEG_mat) contains two folders, namely Session_01 and Session_02, which store datasets recorded on day 1 and day 2, respectively. Within each session folder, there are seventeen.mat files i.e. one for each participant. We have used a similar name convention for all files within the database e.g. in sub-1_ses-1_task-bcimici_meg.mat filename, ‘sub-1’ shows participant Id and ‘ses-1’ stands for session number. Each of these .mat files contains a Matlab structure with name ‘dataMAT’. Table 2 provides names, data type, data size, and description of all the fields present within the ‘dataMAT’ Matlab structure. To provide more flexibility to readers, we have provided the data in both BIDS and .mat file format, which can be downloaded from figshare[13]. The root database folder is (MEG_BIDS) for BIDS format and (MEG_mat) for Matlab.
Table 2

Description of the fields present in the ‘.mat’ files for MEG_mat folder.

Field NameType & SizeDescription
labelcell array [306 × 1]MEG Channel labels
timecell array [1 × 200]Time stamps in accordance with cue
trailcell array [1 × 200]MEG data for 200 trials
fsamplearray [1]Sampling frequency
trialinfoarray [200 × 1]Class labels of 200 trials
gradstructure [1 × 1]A structure containing detailed information about the MEG sensors
trialclasscell array [4 × 2]Classes in number and string information about the MEG sensors
Description of the fields present in the ‘.mat’ files for MEG_mat folder. Each session has 200 trials, stored in a cell array [1 × 200], named ‘data.trial’, and each trial has data from 306 channels for 7 s time duration (i.e. [306 × 7000]), where sampling frequency is 1000 Hz. The class labels are stored in ‘data.trialinfo’ which is an array of size [200 × 1].

Technical Validation

We performed a technical validation of the dataset by estimating and evaluating spatio-temporal features for six binary-classification tasks. For this analysis, MEG data from 204 gradiometer sensors were used while discarding the data from 102 magnetometers, as former provide higher sensor-to-noise ratio and are more sensitive to cortical activations. It is well known that SMRs are more prominent in cortical brain regions. Further, we have selected data for a 3 s time duration i.e. from 0.5 s to 3.5 s after the onset of imagery task. To generate spatio-temporal features, one of the state-of-the-art methods (i.e. filter-bank common spatial pattern (FBCSP)) was employed. This method involves two main steps i.e. band-pass filtering within different frequency ranges (creating a filter-bank) and estimation of CSP features using the band-pass filtered data from previous step[15]. To explore the effect of selecting different combinations of frequency ranges, two filter-banks, namely FB1 and FB2, were created and CSP features were generated for both filter-banks separately. FB1 consisted of two frequency ranges i.e. 8–12 Hz – alpha (α) band and 14–30 Hz– beta (β) band. FB2 consisted of ten overlapping frequency ranges i.e. 8–12 Hz, 10–14 Hz, 12–16 Hz, 14–18 Hz, 16–20 Hz, 18–22 Hz, 20–24 Hz, 22–26 Hz, 24–28 Hz, and 26–30 Hz. To evaluate the BCI performance, classification accuracies (CAs) were estimated by using a support vector machine (SVM) classifier for six binary classification tasks, i.e. hand versus feet (H-F), hand versus word generation (H-W), hand versus subtraction (H-S), feet versus word generation (F-W), feet versus subtraction (F-S), and word generation versus subtraction (W-S). This evaluation was performed for both intra-session condition (i.e. 10-fold cross-validation using Session 1 data) and inter-session condition (i.e. training of classifier with feature set of Session 1 data and evaluation on feature set of Session 2 data). The main reason for using 10-fold cross-validation estimator is that is has a lower variance than a single hold-out set estimator, which can be important if the amount of available data is limited as in our case we have 200 trials in each session. The 10-fold cross-validation (intra-session condition) performance is reported using box plot in Fig. 3 with both filter-bank combinations (i.e. FB1 and FB2) for 6 different binary tasks comparisons (i.e. H-F, H-W, H-S, F-W, F-S, and W-S). The CA for FB1 ranged from 96.29% to 98.29% and for FB2 range from 99% to 99.94%. The overall results showed a high separability between the feature sets of different classes. The results for inter-session condition are reported in Tables 3 and 4 for FB1 and FB2, respectively. For FB1 which includes α and β frequency bands, H-W (i.e. hand vs word) class pair has achieved maximum average (over 17 participants) classification accuracy (i.e. 69.35%), wherein participant sub-3 performed best with 94% and sub-4 has the lowest accuracy of 50%. In FB2, H-S (i.e. hand vs subtraction) class pair has achieved maximum average classification accuracy (i.e. 66.65%), wherein participant sub-20 performed best with 93% and sub-4 has the lowest accuracy 50%. Figure 4 shows comparison between average classification accuracies of FB1 and FB2 for six binary classification tasks in inter-session condition. Here, FB1 performed better than FB2 for majority of class pairs.
Fig. 3

10-fold cross-validation accuracy for Session 1 data under two different filter-banks (1) FB1: Alpha-Beta; (2) FB2: 8–30 Hz, for 6 different binary task comparison (i.e. H-F, H–W, H–S, F–W, F–S, and W-S).

Table 3

Inter-session single-trial classification accuracy (%) for condition FB1 i.e.

Participant IDH-FH-WH-SF-WF-SW-S
sub-1585353615151
sub-2577460856772
sub-3749495706974
sub-4505050505049
sub-6475450585753
sub-7516962876658
sub-9516783507570
sub-11478691838590
sub-12565651685963
sub-13499086918757
sub-14506250545565
sub-15806556697559
sub-16576257627072
sub-17555771557047
sub-18538888456460
sub-19546156576362
sub-20649190879177
Mean56.0669.3567.5966.5967.8863.47
std9.0714.9217.124.9712.0311.29

8–12 Hz (α) and 14–30 Hz β frequency bands. H: Hand; F: Feet; W: Word; and S: subtraction.

Table 4

Inter-session single-trial classification accuracy (%) for condition FB2 i.e.

Participant IDH-FH-WH-SF-WF-SW-S
sub-1594453565050
sub-2515861756554
sub-3769289645272
sub-4505250504650
sub-6555271506352
sub-7525057505350
sub-9515250505051
sub-11496090557452
sub-12555050655264
sub-13478871918754
sub-14506755525576
sub-15668678778256
sub-16586962637467
sub-17496162596557
sub-18507987446546
sub-19505855646351
sub-20649392879384
Mean54.8265.3566.6561.8864.0658.00
std7.6816.2715.2615.2613.6310.77

ten overlapping frequency bands in range between 8–30 Hz. H: Hand; F: Feet; W: Word; and S: subtraction.

Fig. 4

Inter-session classification accuracy-based performance comparison under two conditions FB1 and FB2 for six binary classification tasks.

10-fold cross-validation accuracy for Session 1 data under two different filter-banks (1) FB1: Alpha-Beta; (2) FB2: 8–30 Hz, for 6 different binary task comparison (i.e. H-F, H–W, H–S, F–W, F–S, and W-S). Inter-session single-trial classification accuracy (%) for condition FB1 i.e. 8–12 Hz (α) and 14–30 Hz β frequency bands. H: Hand; F: Feet; W: Word; and S: subtraction. Inter-session single-trial classification accuracy (%) for condition FB2 i.e. ten overlapping frequency bands in range between 8–30 Hz. H: Hand; F: Feet; W: Word; and S: subtraction. Inter-session classification accuracy-based performance comparison under two conditions FB1 and FB2 for six binary classification tasks. Notably, the CAs for inter-session condition is significantly lower than the intra-session condition for all binary classification tasks. Importantly, most of the machine learning methods in BCI are facing an issue of low performance in terms of classification accuracy, which may be due to the presence of non-stationarity in the data recorded over multiple sessions[16,17]. According to the literature, there are several reasons for the presence of non-stationarity in the data such as head movement, user fatigue, change in mood, or external noise interfering the MEG system[18]. We believe that the low CAs in the inter-session condition may be due to the presence of high non-stationarity (i.e. covariate shift) between MEG data of Session 1 and Session 2. The covariate shift is a case, where the input distribution of the data shifts (i.e. (P(x) ≠ P(x))), whereas the conditional probability remains the same, while transitioning from the training to testing stage, which in our case is from Session 1 to Session 2[19-21]). The covariate shift between Session 1 and Session 2 is a challenging issue, as demonstrated by a large difference between the performances of single-trial classification, wherein 10-fold cross-validation average accuracy on Session 1 data is significantly higher than evaluation average accuracy on Session 2 data. We have examined input data distribution between Session 1 and Session 2 for all participants and found that all the participants’ data had some form of covariate shift. Figures 5 and 6 illustrate the presence of covariate shift in the feature set of the participant sub-20 for of α and β frequency bands, respectively. It is to be noted that the sub-20 data provided highest inter-session classification accuracy. Each figure consists of six sub-figures representing distribution between class pairs of six binary classification tasks. In each sub-figure, two ellipses with blue dashed line show the training distribution (P(x)) for the two participating classes (e.g. two classes for top-left sub-figure in Fig. 5 are Hand and Foot imagery) and black dashed line presents the decision hyper-plane for the training dataset. Similarly, the ellipses with red points boundary show the test data distribution P(x) for the same classes and the red dash line presents the decision hyper-plane for the test dataset. A clear shift pattern for the datasets can be seen within both Figs. 5 and 6, i.e. for majority of the class pairs, the training data has high separability as compared to the test data and there are large shifts in decision hyper-planes in most cases. This variation in inter-class separability may explain the low classification accuracies while evaluating the trained classifier with Session 2 data.
Fig. 5

Covariate shift (CS) between the training (Tr) (i.e. Session 1) and test (Ts) (i.e. Session 2) distributions in the α band (i.e. 8–12 Hz) of participant sub-20 dataset for different binary class combinations, where Class 1: Hand, Class 2: Feet, Class 3: Word, and Class 4: Subtraction.

Fig. 6

Covariate shift (CS) between the training (Tr) (i.e. Session 1) and test (Ts) (i.e. Session 2) distributions in the β band (i.e. 14–30 Hz) of participant sub-20 dataset for different binary class combinations, where Class 1: Hand, Class 2: Feet, Class 3: Word, and Class 4: Subtraction.

Covariate shift (CS) between the training (Tr) (i.e. Session 1) and test (Ts) (i.e. Session 2) distributions in the α band (i.e. 8–12 Hz) of participant sub-20 dataset for different binary class combinations, where Class 1: Hand, Class 2: Feet, Class 3: Word, and Class 4: Subtraction. Covariate shift (CS) between the training (Tr) (i.e. Session 1) and test (Ts) (i.e. Session 2) distributions in the β band (i.e. 14–30 Hz) of participant sub-20 dataset for different binary class combinations, where Class 1: Hand, Class 2: Feet, Class 3: Word, and Class 4: Subtraction.

Usage Notes

There are several potential uses for this database. Firstly, it can be used to test the effectiveness of already developed EEG-BCI data analysis pipelines using this MEG dataset. Secondly, we encourage any use that can contribute towards development of novel pattern recognition and machine learning methods to detect brain activities related to MI and CI tasks using MEG signals. Thirdly, since we have performed a basic analysis and single-trial classification of tasks using the raw data, future work may involve exploring impact of various MEG pre-processing methods e.g. head movement correction and maxfiltering[22]. Additionally, as the dataset contains two sessions that were recorded on different days for each participant, robustness of analysis pipelines towards inter-session non-stationarity can be assessed using this dataset. More importantly very high spatial resolution of MEG facilitates much enhanced source-level analysis. The data-sets can used for investigating source level features in accounting for inherent non-stationarity present in MEG neuro-imaging modality primarily due to head movements.
Measurement(s)brain physiology trait
Technology Type(s)Magnetoencephalography
Factor Type(s)age group • sex
Sample Characteristic - OrganismHomo sapiens
  15 in total

1.  Single-trial effective brain connectivity patterns enhance discriminability of mental imagery tasks.

Authors:  Dheeraj Rathee; Hubert Cecotti; Girijesh Prasad
Journal:  J Neural Eng       Date:  2017-06-09       Impact factor: 5.379

2.  Active Physical Practice Followed by Mental Practice Using BCI-Driven Hand Exoskeleton: A Pilot Trial for Clinical Effectiveness and Usability.

Authors:  Anirban Chowdhury; Yogesh Kumar Meena; Haider Raza; Braj Bhushan; Ashwani Kumar Uttam; Nirmal Pandey; Adnan Ariz Hashmi; Alok Bajpai; Ashish Dutta; Girijesh Prasad
Journal:  IEEE J Biomed Health Inform       Date:  2018-08-03       Impact factor: 5.772

3.  Real-time MEG neurofeedback training of posterior alpha activity modulates subsequent visual detection performance.

Authors:  Yuka O Okazaki; Jörn M Horschig; Lisa Luther; Robert Oostenveld; Ikuya Murakami; Ole Jensen
Journal:  Neuroimage       Date:  2014-12-13       Impact factor: 6.556

4.  An MEG-based brain-computer interface (BCI).

Authors:  Jürgen Mellinger; Gerwin Schalk; Christoph Braun; Hubert Preissl; Wolfgang Rosenstiel; Niels Birbaumer; Andrea Kübler
Journal:  Neuroimage       Date:  2007-03-27       Impact factor: 6.556

Review 5.  Brain-computer interfaces in neurological rehabilitation.

Authors:  Janis J Daly; Jonathan R Wolpaw
Journal:  Lancet Neurol       Date:  2008-10-02       Impact factor: 44.182

6.  FieldTrip: Open source software for advanced analysis of MEG, EEG, and invasive electrophysiological data.

Authors:  Robert Oostenveld; Pascal Fries; Eric Maris; Jan-Mathijs Schoffelen
Journal:  Comput Intell Neurosci       Date:  2010-12-23

7.  Short time sports exercise boosts motor imagery patterns: implications of mental practice in rehabilitation programs.

Authors:  Selina C Wriessnegger; David Steyrl; Karl Koschutnig; Gernot R Müller-Putz
Journal:  Front Hum Neurosci       Date:  2014-06-30       Impact factor: 3.169

8.  MEG-BIDS, the brain imaging data structure extended to magnetoencephalography.

Authors:  Guiomar Niso; Krzysztof J Gorgolewski; Elizabeth Bock; Teon L Brooks; Guillaume Flandin; Alexandre Gramfort; Richard N Henson; Mainak Jas; Vladimir Litvak; Jeremy T Moreau; Robert Oostenveld; Jan-Mathijs Schoffelen; Francois Tadel; Joseph Wexler; Sylvain Baillet
Journal:  Sci Data       Date:  2018-06-19       Impact factor: 6.444

9.  Assessing impact of channel selection on decoding of motor and cognitive imagery from MEG data.

Authors:  Sujit Roy; Dheeraj Rathee; Anirban Chowdhury; Karl McCreadie; Girijesh Prasad
Journal:  J Neural Eng       Date:  2020-10-23       Impact factor: 5.379

10.  Covariate shift estimation based adaptive ensemble learning for handling non-stationarity in motor imagery related EEG-based brain-computer interface.

Authors:  Haider Raza; Dheeraj Rathee; Shang-Ming Zhou; Hubert Cecotti; Girijesh Prasad
Journal:  Neurocomputing       Date:  2019-05-28       Impact factor: 5.719

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.