Literature DB >> 3392369

Metered-dose inhaler usage in subjects with asthma: comparison of Nebulizer Chronolog and daily diary recordings.

H Gong1, M S Simmons, V A Clark, D P Tashkin.   

Abstract

The Nebulizer Chronolog (NC) is a portable electronic device that attaches to standard metered-dose inhalers (MDIs) and records and stores the date and time of each MDI actuation. We evaluated the long-term performance of the NC and compared its data to concurrent recordings of self-administered MDI usage in daily diaries. Eighty-three subjects with asthma were evaluated during a 7 1/2-month panel study of air pollution effects. Although 44 (53%) of the NCs developed a malfunction during the study, the average total (+/- SD) percentage of useful days with functioning NCs was still 86 +/- 18% (median 93%). The agreement between the daily diary and NC recordings was very high, that is, 50 (67%) of 75 subjects had perfect agreement. Eighteen subjects with over or under diary reporting were detected. We conclude that the NC is an effective, objective, accurate, and continuous monitor of daily MDI usage despite some remediable technical problems. The NC can facilitate the evaluation of short- and long-term medication usage patterns and compliance issues in MDI-related research and clinical settings.

Entities:  

Mesh:

Year:  1988        PMID: 3392369     DOI: 10.1016/0091-6749(88)90043-7

Source DB:  PubMed          Journal:  J Allergy Clin Immunol        ISSN: 0091-6749            Impact factor:   10.793


  10 in total

1.  Efficacy of calcium channel blockers as maintenance therapy for asthma.

Authors:  Mary Ann Twiss; Eloise Harman; Sarah Chesrown; Leslie Hendeles
Journal:  Br J Clin Pharmacol       Date:  2002-03       Impact factor: 4.335

Review 2.  Deception in clinical trials and its impact on recruitment and adherence of study participants.

Authors:  Chuen Peng Lee; Tyson Holmes; Eric Neri; Clete A Kushida
Journal:  Contemp Clin Trials       Date:  2018-08-21       Impact factor: 2.226

3.  A patient diary as a tool to improve medicine compliance.

Authors:  M T van Berge Henegouwen; H F van Driel; D G Kasteleijn-Nolst Trenité
Journal:  Pharm World Sci       Date:  1999-02

Review 4.  Determinants of adherence in adults with cystic fibrosis.

Authors:  Lisa J Kettler; S M Sawyer; H R Winefield; H W Greville
Journal:  Thorax       Date:  2002-05       Impact factor: 9.139

Review 5.  Automated office blood pressure measurement in primary care.

Authors:  Martin G Myers; Janusz Kaczorowski; Martin Dawes; Marshall Godwin
Journal:  Can Fam Physician       Date:  2014-02       Impact factor: 3.275

6.  Shared treatment decision making improves adherence and outcomes in poorly controlled asthma.

Authors:  Sandra R Wilson; Peg Strub; A Sonia Buist; Sarah B Knowles; Philip W Lavori; Jodi Lapidus; William M Vollmer
Journal:  Am J Respir Crit Care Med       Date:  2009-12-17       Impact factor: 21.405

7.  To what extent can we trust home blood pressure measurement? A randomized, controlled trial.

Authors:  Lucas M Bachmann; Johann Steurer; Dagmar Holm; Wilhem Vetter
Journal:  J Clin Hypertens (Greenwich)       Date:  2002 Nov-Dec       Impact factor: 3.738

Review 8.  Comparative effectiveness of asthma interventions within a practice based research network.

Authors:  Hazel Tapp; Lisa Hebert; Michael Dulin
Journal:  BMC Health Serv Res       Date:  2011-08-16       Impact factor: 2.655

9.  Towards tailored and targeted adherence assessment to optimise asthma management.

Authors:  Job F M van Boven; Jaap C A Trappenburg; Thys van der Molen; Niels H Chavannes
Journal:  NPJ Prim Care Respir Med       Date:  2015-07-16       Impact factor: 2.871

Review 10.  Adherence to disease management programs in patients with COPD.

Authors:  Johnson George; David C M Kong; Kay Stewart
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2007
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.