Increasingly, patients measure and record their home blood pressure. However, the accuracy with which they report their readings to their physicians is largely unknown. The authors assessed the accuracy and quality of self-reported home blood pressure values in an ambulatory managed care population. Forty-eight hypertensive outpatients were randomly allocated to either receive information about the storage capabilities of a home blood pressure measuring device or not to receive such information. All patients were asked to record the measurement results in a logbook twice daily over a 7-day period. The main outcome measure was the difference in the number of fictional or manipulated reports per group and the difference in missing values. The combined parameter manipulated or fictional registrations occurred significantly less frequently in the informed group than in the noninformed group. (10/728 vs. 29/616; relative risk, 0.292; 95% confidence interval, 0.15-0.57; Pearson chi squared=13.15; p<0.0001). Informed patients had fewer missing registrations than the noninformed (13/728 vs. 41/616 measurements; relative risk, 0.27; 95% confidence interval, 0.15-0.47; Pearson chi squared =20.5; p<0.0001). The mean of the fictional data did not differ systematically from the mean of the correctly reported individual blood pressure values. There was no trend to over- or underestimate blood pressure values in the noninformed group. With this study design, it was possible to identify manipulation of home blood pressure values for the first time. Accuracy and interpretation of home blood pressure measurement may be increased by using devices with a memory function. Copyright 2002 Le Jacq Communications, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12461302      PMCID: PMC8101837          DOI: 10.1111/j.1524-6175.2002.00953.x

Source DB:  PubMed          Journal:  J Clin Hypertens (Greenwich)        ISSN: 1524-6175            Impact factor:   3.738


  11 in total

Review 1.  Guidelines for the use of self-blood pressure monitoring: a summary report of the First International Consensus Conference. Groupe Evaluation & Measure of the French Society of Hypertension.

Authors:  R Asmar; A Zanchetti
Journal:  J Hypertens       Date:  2000-05       Impact factor: 4.844

2.  Reliability of patients measuring blood pressure at home: prospective observational study.

Authors:  A Nordmann; B Frach; T Walker; B Martina; E Battegay
Journal:  BMJ       Date:  1999-10-30

3.  Metered-dose inhaler adherence in a clinical trial.

Authors:  C S Rand; R A Wise; M Nides; M S Simmons; E R Bleecker; J W Kusek; V C Li; D P Tashkin
Journal:  Am Rev Respir Dis       Date:  1992-12

4.  Reliability of self-reported blood pressure measurements.

Authors:  K A Johnson; D J Partsch; L L Rippole; D M McVey
Journal:  Arch Intern Med       Date:  1999 Dec 13-27

5.  Metered-dose inhaler usage in subjects with asthma: comparison of Nebulizer Chronolog and daily diary recordings.

Authors:  H Gong; M S Simmons; V A Clark; D P Tashkin
Journal:  J Allergy Clin Immunol       Date:  1988-07       Impact factor: 10.793

6.  Self-measurement of blood pressure: benefits, risks and interpretation of readings. The Canadian Coalition for High Blood Pressure Prevention and Control.

Authors:  N R Campbell; M Bass; A Chockalingam; M LeBel; L Milkovich
Journal:  Can J Cardiol       Date:  1995-11       Impact factor: 5.223

7.  Factors influencing the accuracy of home blood pressure measurement.

Authors:  R D Merrick; K E Olive; R C Hamdy; C Landy; V Cancellaro
Journal:  South Med J       Date:  1997-11       Impact factor: 0.954

8.  Reliability of blood glucose monitoring by patients with diabetes mellitus.

Authors:  R S Mazze; H Shamoon; R Pasmantier; D Lucido; J Murphy; K Hartmann; V Kuykendall; W Lopatin
Journal:  Am J Med       Date:  1984-08       Impact factor: 4.965

9.  Does self-measurement of blood pressure improve patient compliance in hypertension?

Authors:  D Edmonds; E Foerster; H Groth; P Greminger; W Siegenthaler; W Vetter
Journal:  J Hypertens Suppl       Date:  1985-04

10.  Home monitoring of blood pressure: limited value in general practice.

Authors:  G S Stergiou; J S Malakos; A V Voutsa; A D Achimastos; T D Mountokalakis
Journal:  J Hum Hypertens       Date:  1996-04       Impact factor: 3.012

View more
  4 in total

Review 1.  Considering the inclusion of metabolic and cardiovascular markers in the Panel Study of Income Dynamics.

Authors:  Noreen Goldman; Jennifer B Dowd
Journal:  Biodemography Soc Biol       Date:  2009

2.  When tight blood pressure control is not for everyone: a new model for performance measurement in hypertension.

Authors:  Michael A Steinman; Mary K Goldstein
Journal:  Jt Comm J Qual Patient Saf       Date:  2010-04

Review 3.  Practical advice for home blood pressure measurement.

Authors:  Donald W McKay; Marshall Godwin; Arun Chockalingam
Journal:  Can J Cardiol       Date:  2007-05-15       Impact factor: 5.223

4.  Reliability of morning, before-dinner, and at-bedtime home blood pressure measurements in patients with hypertension.

Authors:  Takeshi Fujiwara; Satoshi Hoshide; Hiroshi Kanegae; Masafumi Nishizawa; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-01-06       Impact factor: 3.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.