Effect of High-Intensity Focused Ultrasound on Eyebrow Lifting in Asians.

Won Jong Oh1, Hyun Jung Kwon1, Sun Young Choi2, Kwang Ho Yoo3, Kui Young Park1, Beom Joon Kim1.   

Abstract

Entities:  

Year:  2019        PMID: 33911575      PMCID: PMC7992678          DOI: 10.5021/ad.2019.31.2.223

Source DB:  PubMed          Journal:  Ann Dermatol        ISSN: 1013-9087            Impact factor:   1.444


× No keyword cloud information.
Dear Editor: As skin aging progresses, the elasticity of the skin decreases and facial wrinkles are commonly seen. Various treatment modalities have been applied to treat wrinkles, yet patients are seeking more effective non-invasive methods with lower risk and minimal downtime. High-intensity focused ultrasound (HIFU) technology, originally used in cancer treatment to destroy cancer cells has emerged as an effective, non-surgical, tissue-tightening procedure1. There are several reported results for face, neck, and body tightening with the HIFU device. However, there are few clinical trials that objectively present the efficacy and safety of application of HIFU to the forehead in Asian people. A total of 30 Asian patients (25 females and 5 males) were enrolled in the study. Study approval was granted by the Chung-Ang University Hospital Institutional Review Boards (C2013149[1109]). We received the patient's consent form about publishing all photographic materials. All patients were treated with HIFU device (Ultraformer; Classys Inc., Seoul, Korea) with a 7-MHz, 3-mm transducer to the forehead. Local anesthetic was applied to the target region. Depending on the width of the forehead, the HIFU device was applied along 9 to 11 vertical lines (Fig. 1). Each line consisted of 10 shots at an interval of about 5 mm. After application of ultrasound transmission gel, the HIFU probe was accurately placed with equal pressure to connect to the skin surface. Ultrasound imaging functionality was used to check whether the probe acoustically connected to the skin tissue for treatment and whether the depth of focus was geometrically on the reticular dermis at an intermediate depth. For treatment, 90~110 shots of ultrasound exposure were applied along the lines, and irradiation was performed for 2 seconds or more per ultrasonic pulse. Ultrasonic exposure in the forehead region took about 5 to 10 minutes in total.
Fig. 1

Diagram showing proper distribution of line placement in the treatment region. Danger zones over the relative locations of the temporal branch of trigeminal nerves are highlighted in red.

Before treatment, 4 weeks, and 12 weeks after treatment, standardized photographs of front and side views, rating scale values of pain, adverse events, physical findings, and patient satisfaction were recorded. We measured average eyebrow height (AEH) and maximum eyebrow height (MEH) of the patients. Both medial canthi were connected on images of the facial region seen from the front. On the medial canthi connection line, five points were assigned incrementally at intervals of 8 mm from the inside of the eye and the distance to the top of the eyebrow from each point was measured. The calculated average of the measured values was taken as the AEH, and the maximum distance from the medial canthi connection to the eyebrow was taken as the MEH (Fig. 2). Patients also rated their pain according to a visual analog scale (VAS). All adverse events, including local ones in the facial region, were included in a safety evaluation, and were recorded in the case report form and abnormalities were evaluated.
Fig. 2

Frontal view of a representative patient before (A) and 12 weeks after treatment (B). Note that superimposed lines and numbers are used to objectively measure brow position. Mean AEH and MEH (C) pre-treatment and 4 and 12 weeks post-treatment. AEH: average eyebrow height, MEH: maximum eyebrow height. ***Significant differences, p<0.0001 vs. before by paired t-test.

After application of the HIFU device, mean values of AEH and MEH significantly and progressively increased at 4 weeks and 12 weeks post-treatment compared with 0 weeks (p<0.0001). Mean AEH immediately after treatment (visit 1), at week 4 (visit 2) and week 12 (visit 3) were 29.08±3.17 mm, 30.22±3.24 mm and 30.64±3.28 mm, respectively. The difference in mean AEH from baseline was 1.14±0.29 mm at week 4 (visit 2–visit 1) and 1.56±0.30 mm at week 12 (visit 3–visit 1); both changes were significant (p<0.0001) (Fig. 2). Mean MEH immediately after treatment (visit 1), at week 4 (visit 2) and week 12 (visit 3) were 31.98±3.40 mm, 33.04±3.49 mm and 33.46±3.50 mm, respectively. The difference in the mean MEH from baseline was 1.06±0.34 mm at week 4 (visit 2–visit 1; p<0.0001), and 1.48±0.36 mm at week 12 (visit 3–visit1; p<0.0001) (Fig. 2). Immediately after treatment the mean VAS score for pain was 7.57±1.59, but no pain was reported at weeks 4 and 12. No permanent adverse effects were observed during the follow-up period. Skin tightening by delivery of nonablative energy offers the promise of reduction of wrinkles and sagging with minimal downtime and no serious adverse events2. Collagen is the primary protein in the dermis, together with subcutaneous fat septae and the superficial musculoaponeurotic system (SMAS). Ultrasound energy has specific characteristics that may increase its suitability for skin tightening. First, it is widely believed that energy delivery to the deeper subcutaneous layers of the face, or even the SMAS, is most effective in inducing skin tightening3. Furthermore, to the extent that this delivery can be divorced from secondary scatter and absorption in the epidermis and dermis, the risk of inadvertent cutaneous injury can be reduced. Besides ionizing radiation, ultrasound is the only type of inducible energy that can be delivered arbitrarily deeply into tissue in a selective manner4. Quantification of improved skin elasticity after treatment in a purely objective manner would be of great benefit for skin tightening procedures. As there is a limitation in scientific objectivity for subjective visual assessment from photographic documentation, eyebrow height was assessed using a standard measurement technique56. In this study, to ensure uniform assessment of change in eyebrow elevation, we used AEH and MEH. Several studies have reported that HIFU resulted in an improvement of facial laxity. Alam et al.2 have reported that a single ultrasound treatment of the forehead produced average brow height elevation of 1.7 to 1.9 mm. Suh et al.4 have showed that 61.5% of eyebrows were lifted by at least 0.5 mm at 6 months. Compared with results of the above studies, our study demonstrated significant improvement of forehead skin laxity. In conclusion, we suggest that HIFU would be useful for lax eyelid conditions such as ptosis, as it had a positive effect on eyebrow lifting in Asian people. Future studies could use intense ultrasound probes focused deeper into the tissue to achieve greater tightening efficacy. Higher resolution diagnostic ultrasound imaging would provide better intraoperative visualization of the facial tissue layers, thus facilitating precise treatment and giving better results for skin laxity. Further studies are planned in the field of skin tightening, wrinkle improvement, and skin lifting on other sites of the face.
  6 in total

1.  Multicenter study of noninvasive radiofrequency for periorbital tissue tightening.

Authors:  Richard Fitzpatrick; Roy Geronemus; David Goldberg; Michael Kaminer; Suzanne Kilmer; Javier Ruiz-Esparza
Journal:  Lasers Surg Med       Date:  2003       Impact factor: 4.025

2.  Ultrasound tightening of facial and neck skin: a rater-blinded prospective cohort study.

Authors:  Murad Alam; Lucile E White; Nicolle Martin; Joslyn Witherspoon; Simon Yoo; Dennis P West
Journal:  J Am Acad Dermatol       Date:  2010-02       Impact factor: 11.527

3.  Intense focused ultrasound: evaluation of a new treatment modality for precise microcoagulation within the skin.

Authors:  Hans J Laubach; Inder R S Makin; Peter G Barthe; Michael H Slayton; Dieter Manstein
Journal:  Dermatol Surg       Date:  2008-05       Impact factor: 3.398

4.  Mechanical properties and microstructure of the superficial musculoaponeurotic system.

Authors:  Y Har-Shai; S R Bodner; D Egozy-Golan; E S Lindenbaum; O Ben-Izhak; V Mitz; B Hirshowitz
Journal:  Plast Reconstr Surg       Date:  1996-07       Impact factor: 4.730

5.  A intense-focused ultrasound tightening for the treatment of infraorbital laxity.

Authors:  Dong-Hye Suh; Yu-Jin Oh; Sang-Jun Lee; Ji-Ho Rho; Kye-Yong Song; Nack-In Kim; Min-Kyung Shin
Journal:  J Cosmet Laser Ther       Date:  2012-12       Impact factor: 2.247

6.  Objective changes in brow position, superior palpebral crease, peak angle of the eyebrow, and jowl surface area after volumetric radiofrequency treatments to half of the face.

Authors:  Walter K Nahm; Thomas T Su; Adam M Rotunda; Ronald L Moy
Journal:  Dermatol Surg       Date:  2004-06       Impact factor: 3.398

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.