Partial Respiratory Motion Compensation for Abdominal Extracorporeal Boiling Histotripsy Treatments With a Robotic Arm.

Gilles P L Thomas, Tatiana D Khokhlova, Vera A Khokhlova.   

Abstract

Extracorporeal boiling histotripsy (BH), a noninvasive method for mechanical tissue disintegration, is getting closer to clinical applications. However, the motion of the targeted organs, mostly resulting from the respiratory motion, reduces the efficiency of the treatment. Here, a practical and affordable unidirectional respiratory motion compensation method for BH is proposed and evaluated in ex vivo tissues. The BH transducer is fixed on a robotic arm following the motion of the skin, which is tracked using an inline ultrasound imaging probe. In order to compensate for system lags and obtain a more accurate compensation, an autoregressive motion prediction model is implemented. BH pulse gating is also implemented to ensure targeting accuracy. The system is then evaluated with ex vivo BH treatments of tissue samples undergoing motion simulating breathing with the movement of amplitudes between 5 and 10 mm, the frequency between 16 and 18 breaths/min, and a maximum speed of 14.2 mm/s. Results show a reduction of at least 89% of the value of the targeting error during treatment while only increasing the treatment time by no more than 1%. The lesions obtained by treating with the motion compensation were close in size and affected area to the no-motion case, whereas lesions obtained without the compensation were often incomplete and had larger affected areas. This approach to motion compensation could benefit extracorporeal BH and other histotripsy methods in clinical translation.

Entities:  

Mesh:

Year:  2021        PMID: 33905328      PMCID: PMC8513721          DOI: 10.1109/TUFFC.2021.3075938

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   3.267


  40 in total

1.  3-D real-time motion correction in high-intensity focused ultrasound therapy.

Authors:  Mathieu Pernot; Mickaël Tanter; Mathias Fink
Journal:  Ultrasound Med Biol       Date:  2004-09       Impact factor: 2.998

2.  A case of hepatocellular carcinoma treated by MR-guided focused ultrasound ablation with respiratory gating.

Authors:  Atsuya Okada; Takamichi Murakami; Koji Mikami; Hiromitsu Onishi; Noboru Tanigawa; Taro Marukawa; Hironobu Nakamura
Journal:  Magn Reson Med Sci       Date:  2006-10       Impact factor: 2.471

3.  Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.

Authors:  Baudouin Denis de Senneville; Charles Mougenot; Chrit T W Moonen
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

4.  Visual servoing for a US-guided therapeutic HIFU system by coagulated lesion tracking: a phantom study.

Authors:  Joonho Seo; Norihiro Koizumi; Takakazu Funamoto; Naohiko Sugita; Kiyoshi Yoshinaka; Akira Nomiya; Yukio Homma; Yoichiro Matsumoto; Mamoru Mitsuishi
Journal:  Int J Med Robot       Date:  2011-04-28       Impact factor: 2.547

5.  Numerical and Experimental Study of Mechanisms Involved in Boiling Histotripsy.

Authors:  Ki Joo Pahk; Pierre Gélat; David Sinden; Dipok Kumar Dhar; Nader Saffari
Journal:  Ultrasound Med Biol       Date:  2017-09-28       Impact factor: 2.998

6.  Robotized High Intensity Focused Ultrasound (HIFU) system for treatment of mobile organs using motion tracking by ultrasound imaging: An in vitro study.

Authors:  Laure-Anais Chanel; Florent Nageotte; Jonathan Vappou; Jianwen Luo; Loic Cuvillon; Michel de Mathelin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2015

7.  Preclinical in vivo evaluation of an extracorporeal HIFU device for ablation of pancreatic tumors.

Authors:  Joo Ha Hwang; Yak-Nam Wang; Cinderella Warren; Melissa P Upton; Frank Starr; Yufeng Zhou; Stuart B Mitchell
Journal:  Ultrasound Med Biol       Date:  2009-02-08       Impact factor: 2.998

Review 8.  High-intensity focused ultrasound ablation of breast cancer.

Authors:  Feng Wu; Gail ter Haar; Wei R Chen
Journal:  Expert Rev Anticancer Ther       Date:  2007-06       Impact factor: 4.512

9.  Low dimensional optimization for in vivo real-time porcine liver motion estimation using ultrasound imaging.

Authors:  Jérôme Fehrenbach; Mohamed Masmoudi; David Melodelima
Journal:  Ultrasonics       Date:  2009-07-24       Impact factor: 2.890

10.  First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation.

Authors:  Laura G Merckel; Floor M Knuttel; Roel Deckers; Thijs van Dalen; Gerald Schubert; Nicky H G M Peters; Teun Weits; Paul J van Diest; Willem P Th M Mali; Paul H H B Vaessen; Joost M H H van Gorp; Chrit T W Moonen; Lambertus W Bartels; Maurice A A J van den Bosch
Journal:  Eur Radiol       Date:  2016-02-06       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.