Literature DB >> 33878515

Biomechanical design and analysis of auxetic pedicle screw to resist loosening.

Yan Yao1, Hao Yuan2, Huiwen Huang3, Jinglong Liu4, Lizhen Wang5, Yubo Fan6.   

Abstract

BACKGROUND: Pedicle screws are widely used in fusion surgery, while screw loosening often occurrs. An auxetic structures based pedicle screw was proposed to improve the bone-screw fixation by radial expansion of the screw body under tensile force to resist pulling out. It was optimized to obtain excellent anti-pullout ability for a particular bone based on the biomechanical interaction between screw and surrounding bone.
METHODS: The screw was designed based on re-entrant unit cells. The mechanical properties of it were adjusted by the wall thickness (t) and re-entrant angle (θ) of the unit cell, and characterized using finite element (FE) method. The designed screws were manufactured using 3D-printing, and Ti6Al4V as the materials. Subsequently, the pullout FE models were established, and verified by pulling the fabricated screws out of Sawbone blocks. The pulling out processes of screws from bone were simulated to explore the optimizing design of the screw.
RESULTS: The mechanical properties of the screw could be adjusted in a wide range. The biomechanical interaction between the screw and bone can affect the anti-pullout performance of the screw. With an identical elastic modulus (E), better auxiticity of the screw, resulted in a better anti-pullout performance; while an appropriate E is the necessary condition for its excellent anti-pullout performance for a particular bone.
CONCLUSION: Appropriate mechanical properties are necessary for the auxetic pedicle screw with excellent screw-bone fixation performance for a particular bone, which can be obtained by rationally designing the wall thickness and re-entrant angle of the unit cells.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Keywords:  3D printing; Auxetic structure; Biomechanical analysis; Optimization design; Pedicle screw

Year:  2021        PMID: 33878515     DOI: 10.1016/j.compbiomed.2021.104386

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  2 in total

1.  Functionally graded additive manufacturing for orthopedic applications.

Authors:  Saquib Rouf; Abrar Malik; Ankush Raina; Mir Irfan Ul Haq; Nida Naveed; Ali Zolfagharian; Mahdi Bodaghi
Journal:  J Orthop       Date:  2022-07-03

Review 2.  Auxetic Metamaterials for Biomedical Devices: Current Situation, Main Challenges, and Research Trends.

Authors:  Vladislav A Lvov; Fedor S Senatov; Alnis A Veveris; Vitalina A Skrybykina; Andrés Díaz Lantada
Journal:  Materials (Basel)       Date:  2022-02-15       Impact factor: 3.623

  2 in total