Literature DB >> 33877970

Noise Suppression for Ultrasound Attenuation Coefficient Estimation Based on Spectrum Normalization.

Ping Gong, Pengfei Song, Chengwu Huang, U-Wai Lok, Shanshan Tang, Chenyun Zhou, Lulu Yang, Kymberly D Watt, Matthew Callstrom, Shigao Chen.   

Abstract

Ultrasound attenuation coefficient estimation (ACE) has great diagnostic potential for fatty liver detection and assessment. In a previous study, we proposed a reference phantom-free ACE method, called reference frequency method (RFM), which does not require a calibrated phantom for normalization. The power of each frequency component can be normalized by the power of an adjacent frequency component in the spectrum to cancel system-dependent effects such as focusing and time gain compensation (TGC). RFM demonstrated accurate ACE in both phantom and in in-vivo liver studies. However, our study also showed that the robustness and penetration of RFM were affected by noise in the ACE signals. Here we propose a noise suppression (NS) and a signal-to-noise ratio (SNR) quality control method to reduce the influence of noise on ACE-RFM performance. The proposed methods were tested in harmonic ACE because harmonic imaging is a more frequently used mode than fundamental imaging for abdominal applications. After applying the NS and SNR control methods, the noise-induced bias for attenuation estimation in harmonic ACE was effectively reduced, leading to significantly improved effective penetration depth. The proposed methods directly measure the noise spectrum of the ultrasound system, which can also be adapted to other spectrum-based ACE methods, such as the reference phantom method and the spectra shift method.

Entities:  

Mesh:

Year:  2021        PMID: 33877970      PMCID: PMC8344359          DOI: 10.1109/TUFFC.2021.3074293

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   3.267


  24 in total

1.  Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging.

Authors:  Chengwu Huang; Pengfei Song; Ping Gong; Joshua D Trzasko; Armando Manduca; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-05-22       Impact factor: 2.725

2.  Feasibility study of ultrasonic fatty liver biopsy: texture vs. attenuation and backscatter.

Authors:  Diana Gaitini; Yaacov Baruch; Eduard Ghersin; Ella Veitsman; Hedvika Kerner; Bruria Shalem; Geva Yaniv; Chen Sarfaty; Haim Azhari
Journal:  Ultrasound Med Biol       Date:  2004-10       Impact factor: 2.998

3.  Comparison of techniques for in vivo attenuation measurements.

Authors:  K J Parker; R M Lerner; R C Waag
Journal:  IEEE Trans Biomed Eng       Date:  1988-12       Impact factor: 4.538

4.  Prospective Evaluation of Hepatic Steatosis Using Ultrasound Attenuation Imaging in Patients with Chronic Liver Disease with Magnetic Resonance Imaging Proton Density Fat Fraction as the Reference Standard.

Authors:  Sun Kyung Jeon; Jeong Min Lee; Ijin Joo; Jeong Hee Yoon; Dong Ho Lee; Jae Young Lee; Joon Koo Han
Journal:  Ultrasound Med Biol       Date:  2019-04-08       Impact factor: 2.998

5.  EASL-EASD-EASO Clinical Practice Guidelines for the management of non-alcoholic fatty liver disease.

Authors: 
Journal:  J Hepatol       Date:  2016-04-07       Impact factor: 25.083

6.  Frequency dependence of ultrasound attenuation and backscatter in breast tissue.

Authors:  F T D'Astous; F S Foster
Journal:  Ultrasound Med Biol       Date:  1986-10       Impact factor: 2.998

7.  Measurement of ultrasonic attenuation within regions selected from B-scan images.

Authors:  K J Parker; R C Waag
Journal:  IEEE Trans Biomed Eng       Date:  1983-08       Impact factor: 4.538

8.  Reduced-order autoregressive modeling for center-frequency estimation.

Authors:  R Kuc; H Li
Journal:  Ultrason Imaging       Date:  1985-07       Impact factor: 1.578

9.  Simultaneous backscatter and attenuation estimation using a least squares method with constraints.

Authors:  Kibo Nam; James A Zagzebski; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2011-10-02       Impact factor: 2.998

Review 10.  Quantitative Imaging Biomarkers of NAFLD.

Authors:  Sonja Kinner; Scott B Reeder; Takeshi Yokoo
Journal:  Dig Dis Sci       Date:  2016-02-05       Impact factor: 3.199

View more
  2 in total

1.  Improved Ultrasound Attenuation Estimation with Non-uniform Structure Detection and Removal.

Authors:  Ping Gong; Chengwu Huang; U-Wai Lok; Shanshan Tang; Wenwu Ling; Chenyun Zhou; Lulu Yang; Kymberly D Watt; Matthew Callstrom; Shigao Chen
Journal:  Ultrasound Med Biol       Date:  2022-08-26       Impact factor: 3.694

2.  Reverberation clutter signal suppression in ultrasound attenuation estimation using wavelet-based robust principal component analysis.

Authors:  U-Wai Lok; Ping Gong; Chengwu Huang; Shanshan Tang; Chenyun Zhou; Lulu Yang; Kymberly D Watt; Matthew Callstrom; Joshua D Trzasko; Shigao Chen
Journal:  Phys Med Biol       Date:  2022-04-28       Impact factor: 4.174

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.