Literature DB >> 33876968

Disposable Coverslip for Rapid Throughput Screening of Malaria Using Attenuated Total Reflection Spectroscopy.

Thulya Chakkumpulakkal Puthan Veettil1, Kamila Kochan1, Karen J Edler2, Paul De Bank3, Philip Heraud1, Bayden R Wood1.   

Abstract

Malaria is considered to be one of the most catastrophic health issues in the whole world. Vibrational spectroscopy is a rapid, robust, label-free, inexpensive, highly sensitive, nonperturbative, and nondestructive technique with high diagnostic potential for the early detection of disease agents. In particular, the fingerprinting capability of attenuated total reflection spectroscopy is promising as a point-of-care diagnostic tool in resource-limited areas. However, improvements are required to expedite the measurements of biofluids, including the drying procedure and subsequent cleaning of the internal reflection element to enable high throughput successive measurements. As an alternative, we propose using an inexpensive coverslip to reduce the sample preparation time by enabling multiple samples to be collectively dried together under the same temperature and conditions. In conjunction with partial least squares regression, attenuated total reflection spectroscopy was able to detect and quantify the parasitemia with root mean square error of cross-validation and R2 values of 0.177 and 0.985, respectively. Here, we characterize an inexpensive, disposable coverslip for the high throughput screening of malaria parasitic infections and thus demonstrate an alternative approach to direct deposition of the sample onto the internal reflection element.

Entities:  

Keywords:  ATR FT-IR spectroscopy; Infrared substrates; PLSR; attenuated total reflection Fourier transform infrared; malaria diagnosis; partial least squares regression

Mesh:

Year:  2021        PMID: 33876968     DOI: 10.1177/00037028211012722

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  2 in total

1.  A Combined Near-Infrared and Mid-Infrared Spectroscopic Approach for the Detection and Quantification of Glycine in Human Serum.

Authors:  Thulya Chakkumpulakkal Puthan Veettil; Bayden R Wood
Journal:  Sensors (Basel)       Date:  2022-06-15       Impact factor: 3.847

2.  Haemoprocessor: A Portable Platform Using Rapid Acoustically Driven Plasma Separation Validated by Infrared Spectroscopy for Point-of-Care Diagnostics.

Authors:  Kamal Prakash Prasanna Ravindran Nair; Thulya Chakkumpulakkal Puthan Veettil; Bayden R Wood; Debjani Paul; Tuncay Alan
Journal:  Biosensors (Basel)       Date:  2022-02-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.