Literature DB >> 33866558

Initial clinical experiences using the intraoperative probe-based parathyroid autofluorescence identification system-PTeye™ during thyroid and parathyroid procedures.

Colleen M Kiernan1, Giju Thomas2,3, Naira Baregamian1, Carmen C Solόrzano1.   

Abstract

BACKGROUND AND
OBJECTIVE: The Food and Drug Administration has cleared a probe-based near-infrared autofluorescence (NIRAF) detection system called PTeye™ as an adjunct tool for label-free intraoperative parathyroid gland (PG) identification. Since PTeye™ has been investigated only in a "blinded" manner to date, this study describes the preliminary impressions of PTeye™ when used by surgeons without being blinded to the device output.
METHODS: Patients undergoing thyroid and parathyroid procedures were prospectively recruited. Target tissues were intraoperatively assessed with PTeye™. The surgeon's confidence in PG identification was recorded concomitantly with NIRAF parameters that were output in real-time from PTeye™.
RESULTS: A retrospective review of prospectively collected data on 83 patients was performed. PTeye™ was used for interrogating 336 target tissues in 46 parathyroid and 37 thyroid procedures. PTeye™ yielded an overall accuracy of 94.3% with a positive predictive value of 93.0% and a negative predictive value of 100%. An increase in confidence for intraoperative PG identification with PTeye™ was observed by all three participating high-volume surgeons, irrespective of their level of accrued surgical experience.
CONCLUSIONS: Probe-based NIRAF detection with PTeye™ can be a valuable adjunct device to intraoperatively identify PGs for surgeons of varied training and experience.
© 2021 Wiley Periodicals LLC.

Entities:  

Keywords:  autofluorescence; near-infrared; parathyroid gland; parathyroidectomy; surgical guidance; thyroidectomy

Mesh:

Year:  2021        PMID: 33866558      PMCID: PMC8319062          DOI: 10.1002/jso.26500

Source DB:  PubMed          Journal:  J Surg Oncol        ISSN: 0022-4790            Impact factor:   2.885


  36 in total

Review 1.  Reoperative parathyroidectomy.

Authors:  Alfred Simental; Robert L Ferris
Journal:  Otolaryngol Clin North Am       Date:  2008-12       Impact factor: 3.346

Review 2.  Systematic review and meta-analysis of predictors of post-thyroidectomy hypocalcaemia.

Authors:  O Edafe; R Antakia; N Laskar; L Uttley; S P Balasubramanian
Journal:  Br J Surg       Date:  2014-01-09       Impact factor: 6.939

3.  Autofluorescence in Parathyroidectomy: Signal Intensity Correlates with Serum Calcium and Parathyroid Hormone but Routine Clinical Use is Not Justified.

Authors:  Aimee DiMarco; Ravi Chotalia; Ruth Bloxham; Charlotte McIntyre; Neil Tolley; F Fausto Palazzo
Journal:  World J Surg       Date:  2019-06       Impact factor: 3.352

4.  Interinstitutional comparison of frozen section turnaround time. A College of American Pathologists Q-Probes study of 32868 frozen sections in 700 hospitals.

Authors:  D A Novis; R J Zarbo
Journal:  Arch Pathol Lab Med       Date:  1997-06       Impact factor: 5.534

5.  Heterogeneous and low-intensity parathyroid autofluorescence: Patterns suggesting hyperfunction at parathyroid exploration.

Authors:  Emin Kose; Bora Kahramangil; Husnu Aydin; Mustafa Donmez; Eren Berber
Journal:  Surgery       Date:  2018-09-28       Impact factor: 3.982

6.  Developing a Clinical Prototype to Guide Surgeons for Intraoperative Label-Free Identification of Parathyroid Glands in Real Time.

Authors:  Giju Thomas; Melanie A McWade; Constantine Paras; Emmanuel A Mannoh; Melinda E Sanders; Lisa M White; James T Broome; John E Phay; Naira Baregamian; Carmen C Solórzano; Anita Mahadevan-Jansen
Journal:  Thyroid       Date:  2018-09-11       Impact factor: 6.568

Review 7.  Detecting the Near Infrared Autofluorescence of the Human Parathyroid: Hype or Opportunity?

Authors:  Carmen C Solórzano; Giju Thomas; Naira Baregamian; Anita Mahadevan-Jansen
Journal:  Ann Surg       Date:  2020-12       Impact factor: 12.969

8.  Intraoperative scintigraphy using a large field-of-view portable gamma camera for primary hyperparathyroidism: initial experience.

Authors:  Nathan C Hall; Robert L Plews; Amit Agrawal; Stephen P Povoski; Chadwick L Wright; Jun Zhang; Edward W Martin; John Phay
Journal:  Biomed Res Int       Date:  2015-01-06       Impact factor: 3.411

9.  Patient Eligibility for Transoral Endocrine Surgery Procedures in the United States.

Authors:  Raymon H Grogan; Insoo Suh; Kate Chomsky-Higgins; Salman Alsafran; Elya Vasiliou; Christopher R Razavi; Lena W Chen; Ralph P Tufano; Quan-Yang Duh; Peter Angelos; Jonathon O Russell
Journal:  JAMA Netw Open       Date:  2019-05-03

10.  Intraoperative Autofluorescence and Indocyanine Green Angiography for the Detection and Preservation of Parathyroid Glands.

Authors:  Marco Stefano Demarchi; Wolfram Karenovics; Benoît Bédat; Frédéric Triponez
Journal:  J Clin Med       Date:  2020-03-18       Impact factor: 4.241

View more
  1 in total

1.  Influence of Single Experience with Intraoperative Near-Infrared Autofluorescence on Postoperative Parathyroid Insufficiency after Thyroidectomy - A Preliminary Clinical Study.

Authors:  Paweł Domosławski; Marcin Adamiecki; Łukasz Antkowiak; Krzysztof Paśko; Mariusz Chabowski; Jędrzej Grzegrzółka; Michał Zrąbkowski; Jacek Białecki; Ryszard Antkowiak
Journal:  Int J Med Sci       Date:  2022-07-18       Impact factor: 3.642

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.