Artur Igor Milnerowicz1, Aleksandra Milnerowicz1, Tomasz Bańkowski2, Marcin Protasiewicz3.
Abstract
PURPOSE: The use of the pressure gradient measurements to assess the renal artery flow hemodynamics after chimney endovascular aortic repair (chEVAR).Entities:
Year: 2021 PMID: 33852618 PMCID: PMC8046246 DOI: 10.1371/journal.pone.0249549
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Demographic and clinical characteristics of the study patients.
| Parameter | Value |
|---|---|
| Mean age (years) | 71.4 ±7.3 |
| Sex (F/M) | 6/18 |
| Diabetes, n (%) | 5/24 (20.8) |
| Hypertension, n (%) | 18/24 (75) |
| Smoking, n (%) | 8/24 (33.3) |
| COPD, n (%) | 7/24 (29,1) |
| Previous MI, n (%) | 4/24 (16,6) |
| Dyslipidemia, n (%) | 16/24 (66,6) |
| Hemoglobin (g/dl) | 12.9±1.7 |
COPD—chronic obstructive pulmonary disease,MI—myocardial infarction.
Fig 1Stentgraft and chimney stents after implantation.
A. Angiographic picture during the procedure (arrow -guide catheter for chimney stent implantation and pressure wire delivery). B. Follow up computed tomography after 6 months—patency of both chimney stents.
Anatomical and clinical characteristics of the study patients.
| Parameter | Value |
|---|---|
| Preoperative mean aneurysm diameter (mm) | 71.7±11 |
| Preoperative proximal neck length (mm) | 8.6±7 |
| Preoperative suprarenal neck angulation (degrees) | 25.1±14 |
| Mean renal artery stenosis (%) | 26.2±12.3 |
| Chimney stent diameter (mm) | 6.5±0.6 |
| Chimney stent length (mm) | 52.1±9.4 |
| Number (%) of patients who received: | |
| • 1 chimney | 11/24 (45.8) |
| • 2 chimneys | 12/24 (50) |
| • 3 chimneys | 1/24 (4.2) |
| Amount of contrast agent used (ml) | 12.9±1.7 |
| Fluoroscopy time (min) | 36.7±26.4 |
| Creatinine level before the procedure (mg/dl) | 1.2±0.4 |
| Creatinine level 3 days after the procedure (mg/dl) | 1.3±0.5 |
| Endoleak Ia incidence after 6 months, n (%) | 4/37 (10.8) |
| Chimney graft occlusion after 6 months, n (%) | 0/37 (0) |
Fig 2Changes in mean blood pressure gradient before and after chimney implantation.
Not significant increase in mean gradient after chEVAR procedure as compared to pre-procedural measurement.
Fig 3Changes in Pd/Pa before and after chimney implantation.
No difference in Pd/Pa ratio before and after chEVAR procedure.