Literature DB >> 3383373

Extracellular field required for excitation in three-dimensional anisotropic canine myocardium.

D W Frazier1, W Krassowska, P S Chen, P D Wolf, E G Dixon, W M Smith, R E Ideker.   

Abstract

It is not known how well potential gradient, current density, and energy correlate with excitation by extracellular stimulation in the in situ heart. Additionally, the influence of fiber orientation and stimulus polarity on the extracellular thresholds for stimulation expressed in terms of these factors has not been assessed. To answer these questions for myocardium in electrical diastole, extracellular excitation thresholds were determined from measurements of stimulus potentials and activation patterns recorded from 120 transmural electrodes in a 35 X 20 X 5-mm region of the right ventricular outflow tract in six open-chest dogs. Extracellular potential gradients, current densities, energies, and their components longitudinal and transverse to the local fiber orientation at each recording site were calculated from the stimulus potentials produced by 3-msec constant-current stimuli. The resulting values in regions directly excited by the stimulus field were compared with the values in regions not directly excited but activated by the spread of wavefronts conducting away from the directly excited region. Magnitudes of 3.66 mA/cm2 for current density, 9.7 microJ/cm3 for energy, and 804 mV/cm for potential gradient yielded minimum misclassifications of 8%, 13%, and 17%, respectively, of sites directly and not directly excited. A linear bivariate combination of the longitudinal (l) and transverse (t) components of the potential gradient yielded 7% misclassification (threshold ratio t/l of 2.88), and linear combination of corresponding current density components yielded 8% misclassification (threshold ratio t/l of 1.04). Anodal and cathodal thresholds were not significantly different (p = 0.39). Potential gradient, current density, and energy strength-duration curves were constructed for pulse durations (D) of 0.2-20 msec. The best fit hyperbolic curve for current density magnitude (Jm) was Jm = 3.97/D + 3.15, where Jm is in mA/cm2, and D is in msec. Thus, for stimulation during electrical diastole 1) both current density magnitude and longitudinal and transverse components of the potential gradient are closely correlated with excitation, 2) the extracellular potential gradient along cardiac cells has a lower threshold than across cells, while current density thresholds along and across cells are similar, 3) anodal and cathodal thresholds are approximately equal for stimuli greater than or equal to 5 mA, and 4) the extracellular potential gradient, current density, and energy excitation thresholds can be expressed by strength-duration equations.

Entities:  

Mesh:

Year:  1988        PMID: 3383373     DOI: 10.1161/01.res.63.1.147

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  11 in total

1.  Roles of electric field and fiber structure in cardiac electric stimulation.

Authors:  S B Knisley; N Trayanova; F Aguel
Journal:  Biophys J       Date:  1999-09       Impact factor: 4.033

2.  Modelling induction of a rotor in cardiac muscle by perpendicular electric shocks.

Authors:  K Skouibine; J Wall; W Krassowska; N Trayanova
Journal:  Med Biol Eng Comput       Date:  2002-01       Impact factor: 2.602

3.  Cell-attached patch clamp study of the electropermeabilization of amphibian cardiac cells.

Authors:  R J O'Neill; L Tung
Journal:  Biophys J       Date:  1991-05       Impact factor: 4.033

4.  Spatial distribution of cardiac transmembrane potentials around an extracellular electrode: dependence on fiber orientation.

Authors:  M Neunlist; L Tung
Journal:  Biophys J       Date:  1995-06       Impact factor: 4.033

5.  Electrical stimulation of cardiac myocytes.

Authors:  R Ranjan; N V Thakor
Journal:  Ann Biomed Eng       Date:  1995 Nov-Dec       Impact factor: 3.934

6.  Virtual electrode effects in myocardial fibers.

Authors:  S B Knisley; B C Hill; R E Ideker
Journal:  Biophys J       Date:  1994-03       Impact factor: 4.033

7.  Effects of anisotropic myocardial conductivity in model of defibrillation current density distribution.

Authors:  M Malik; K F Smits; F W Lindemans
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

8.  [Mechanisms of electrical defibrillation].

Authors:  S Reek; R E Ideker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

9.  Stimulus-induced critical point. Mechanism for electrical initiation of reentry in normal canine myocardium.

Authors:  D W Frazier; P D Wolf; J M Wharton; A S Tang; W M Smith; R E Ideker
Journal:  J Clin Invest       Date:  1989-03       Impact factor: 14.808

10.  High defibrillation threshold: the science, signs and solutions.

Authors:  Sony Jacob; Victorio Pidlaoan; Jaspreet Singh; Aditya Bharadwaj; Mehul B Patel; Antonio Carrillo
Journal:  Indian Pacing Electrophysiol J       Date:  2010-01-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.