Literature DB >> 3383318

Critical incidents detected by pulse oximetry during anaesthesia.

W P McKay1, W H Noble.   

Abstract

The Critical Incident Technique was used to study anaesthetics given in a major tertiary care teaching hospital in order to define indications for monitoring with a pulse oximeter during anaesthesia. Anaesthetists were asked to use a pulse oximeter in every case and trained to report Critical Incidents in order to determine if the oximeter can shorten the time to detection of these events. Four thousand seven hundred and ninety-seven anaesthetics were given during a four-month period in 1986-87. A Critical Incident was recorded when an unexpected physiologic deterioration requiring intervention by the anaesthetist to prevent a likely bad outcome was signalled first by the pulse oximeter. Critical Incidents were classified by patient characteristics, physiologic change, type of anaesthetic, and the type, length, and place of surgery. Reports were received in 65 per cent of cases, and a Critical Incident occurred in 191 (six per cent) of these. Desaturation was the commonest physiologic change (151) and was further classified as to severity (mild 85-94 per cent saturation, moderate 75-84 per cent, and severe 75 per cent). Desaturations during the maintenance phase of anaesthesia were milder but more frequent than those in the induction or emergence phases. There were no severe desaturations in elderly patients or those receiving regional anaesthesia. No group was free of Critical Incidents. Since undetected hypoxaemia may lead to disastrous complications we recommend that a pulse oximeter be used for every anaesthetic.

Entities:  

Mesh:

Year:  1988        PMID: 3383318     DOI: 10.1007/BF03010621

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  17 in total

1.  The critical incident technique.

Authors:  J C FLANAGAN
Journal:  Psychol Bull       Date:  1954-07       Impact factor: 17.737

2.  Oximetry--know thy limits.

Authors:  A L Ries
Journal:  Chest       Date:  1987-03       Impact factor: 9.410

3.  Clinical recognition of hypoxaemia under fluorescent lamps.

Authors:  G R Kelman; J F Nunn
Journal:  Lancet       Date:  1966-06-25       Impact factor: 79.321

4.  The Nellcor N-101 pulse oximeter. A clinical evaluation in anaesthesia and intensive care.

Authors:  J A Tytler; H F Seeley
Journal:  Anaesthesia       Date:  1986-03       Impact factor: 6.955

5.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

6.  Infrared heat lamps interfere with pulse oximeters.

Authors:  T D Brooks; D A Paulus; W E Winkle
Journal:  Anesthesiology       Date:  1984-11       Impact factor: 7.892

7.  Effects of information feedback and pulse oximetry on the incidence of anesthesia complications.

Authors:  J B Cooper; D J Cullen; R Nemeskal; D C Hoaglin; C C Gevirtz; M Csete; C Venable
Journal:  Anesthesiology       Date:  1987-11       Impact factor: 7.892

8.  An analysis of major errors and equipment failures in anesthesia management: considerations for prevention and detection.

Authors:  J B Cooper; R S Newbower; R J Kitz
Journal:  Anesthesiology       Date:  1984-01       Impact factor: 7.892

9.  Evaluation of arterial oxygenation during anaesthesia.

Authors:  R L Knill
Journal:  Can Anaesth Soc J       Date:  1985-05

10.  The current status of pulse oximetry. Clinical value of continuous noninvasive oxygen saturation monitoring.

Authors:  M B Taylor; J G Whitwam
Journal:  Anaesthesia       Date:  1986-09       Impact factor: 6.955

View more
  7 in total

Review 1.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 2.  Pulse oximetry and capnography in anaesthetic practice: an epidemiological appraisal.

Authors:  P G Duncan; M M Cohen
Journal:  Can J Anaesth       Date:  1991-07       Impact factor: 5.063

3.  Influence of pulse oximetry and capnography on time to diagnosis of critical incidents in anesthesia: a pilot study using a full-scale patient simulator.

Authors:  S Lampotang; J S Gravenstein; T Y Euliano; W L van Meurs; M L Good; P Kubilis; R Westhorpe
Journal:  J Clin Monit Comput       Date:  1998-07       Impact factor: 2.502

4.  Anaesthetic monitoring: clinical practice in anaesthetic rooms and theatres.

Authors:  D G Wright; I M Bali
Journal:  Ulster Med J       Date:  1993-04

5.  Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults.

Authors:  I Ahmad; K El-Boghdadly; R Bhagrath; I Hodzovic; A F McNarry; F Mir; E P O'Sullivan; A Patel; M Stacey; D Vaughan
Journal:  Anaesthesia       Date:  2019-11-14       Impact factor: 6.955

6.  Critical care and perioperative monitoring.

Authors:  Dimitrios Karakitsos; Mahmoud El Barbary; Lawrence Marshall Gillman; Apostolos Papalois; Ariel Shiloh
Journal:  ScientificWorldJournal       Date:  2014-05-04

7.  Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland.

Authors:  M R Checketts; R Alladi; K Ferguson; L Gemmell; J M Handy; A A Klein; N J Love; U Misra; C Morris; M H Nathanson; G E Rodney; R Verma; J J Pandit
Journal:  Anaesthesia       Date:  2015-11-19       Impact factor: 6.955

  7 in total