Literature DB >> 33823203

Effect of varying storage conditions on diagnostic test outcomes of SARS-CoV-2.

Satoshi Oguri1, Shinichi Fujisawa1, Keisuke Kamada2, Sho Nakakubo3, Yu Yamashita3, Junichi Nakamura3, Hiroshi Horii3, Kazuki Sato3, Mutsumi Nishida1, Takanori Teshima4, Yoichi Ohiro5, Ayato Takada6, Satoshi Konno3.   

Abstract

Entities:  

Keywords:  Antigen test; COVID-19 testing; Diagnostic techniques and procedures; Virus infectious titer

Mesh:

Year:  2021        PMID: 33823203      PMCID: PMC8018904          DOI: 10.1016/j.jinf.2021.03.026

Source DB:  PubMed          Journal:  J Infect        ISSN: 0163-4453            Impact factor:   6.072


× No keyword cloud information.
Dear Editor, Iwasaki et al. previously demonstrated the usefulness of saliva polymerase chain reaction (PCR) in diagnosing coronavirus disease (COVID-19). Thereafter, several studies reported the simplicity and usefulness of saliva PCR and antigen tests. , However, the most appropriate method for storing saliva specimens remains elusive. Any samples for COVID-19-related investigations should ideally be processed immediately after procurement. However, limited availability of measuring equipment and manpower may warrant the need to preserve samples in certain conditions until they are tested. Additionally, preserved samples may contribute to retrospective research. However, the differences in the results of several COVID-19-related tests under variable storage conditions (temperature, freezing/thawing, and solute medium) are not evaluated. We aimed to examine how variations in sample storage conditions affected results of antigen testing, PCR, and virus infectious titers for SARS-CoV-2. Antigen testing was performed by LUMIPULSE® (Fujirebio, Inc.,Tokyo, Japan). , We analyzed specimens from eight patients who were examined at Hokkaido University Hospital from May 2020 to January 2021. The correspondence between patients and specimen numbers is as follows: Patient1 (swab1, saliva1), Patient2 (swab2), Ptatient3 (saliva2), Patient4 (swab3), Patient5 (saliva3), Patient6 (saliva4), Patient7 (saliva5), Patient8 (saliva6). Nasopharyngeal samples were obtained using FLOQSwabs® (COPAN, Murrieta, CA, USA). The swab was inserted into the nostril up till the posterior nasopharynx and then gently removed while rotating. Thereafter, the swabs were placed in saline prior to evaluation. Saliva samples were self-collected by the patients. We instructed them to spit saliva o sterile PP Screw cup 50® (ASIAKIZAI Co., Tokyo, Japan) that naturally accumulates in the mouth into a cup twice and not to eat, drink, gargle, or brush their teeth for 10 min before specimen collection. Subsequently, 200 μL saliva was added to 600 μL phosphate-buffered saline, mixed vigorously, and centrifuged (20,000 x g; 5 min; 4 °C); the supernatant (140 μL) was used as a sample. To investigate the PCR cycle threshold (Ct) values and antigen titers, swabs (swab1, 2) placed in saline were diluted using saline or CELLBANKER® (ZENOAQ RESOURCE Co., Fukushima, Japan), then preserved either at ambient temperature (AT), 4 °C, or −30 °C. Saliva samples (saliva1, 2) were preserved either at, 4 °C, or −30 °C, and diluted with PBS immediately before testing. To investigate whether freezing and thawing affected virus cultures, we measured the virus infectious titer of one swab (swab 3) and four undiluted saliva (saliva 3,4,5,6) samples before freezing and after freezing and thawing. The detailed methodologies are reported previously and in online supplementary material.

Comparing the stability of saline and CELLBANKER® as preservation media for nasopharyngeal swabs

Fig. 1 A shows the changes in antigen titers of the samples preserved in saline and CELLBANKER®. The antigen titers for samples preserved in saline decreased until 72 h (AT and 4 °C). Contrastingly, no such reduction was seen for samples preserved in CELLBANKER® (AT and 4 °C). When samples were frozen at −30 °C and then thawed, the antigen titers decreased in samples preserved with saline but not in those preserved with CELLBANKER®. However, Fig. 1B shows that the PCR Ct values remained unchanged under all preservation conditions.
Fig. 1

Changes in virus antigen titer and PCR Ct values in Nasopharyngeal swabs and saliva samples. (A) virus antigen titer of nasopharyngeal swab, (B) RT-qPCR Ct value of nasopharyngeal swab, (C) virus antigen titer of saliva, (D) RT-qPCR Ct value of saliva.

Changes in virus antigen titer and PCR Ct values in Nasopharyngeal swabs and saliva samples. (A) virus antigen titer of nasopharyngeal swab, (B) RT-qPCR Ct value of nasopharyngeal swab, (C) virus antigen titer of saliva, (D) RT-qPCR Ct value of saliva. Our study revealed that antigen titers were significantly lower in nasopharyngeal swab samples that were preserved in saline than in CELLBANKER®. This may be due to the trapping of antigen on the wall of the tube for non-specific binding with the former method. The decrease over time in antigen titers of samples preserved in saline relative to those preserved in CELLBANKER® persisted after 72 h (supplemental data). Therefore, preserving nasopharyngeal swab specimens in saline may incur false negative results. CELLBANKER® was developed to prevent the degradation of nucleic acids and protect the cell membrane, particularly during experiments. Although the exact mechanism influencing the virus’ stability remains unclear, our findings indicate that CELLBANKER® is more effective than saline as a preservation medium for nasopharyngeal swab samples collected for antigen testing.

Stability of saliva samples in varying preservation conditions

For saliva samples preserved at AT and 4 °C, antigen titers and Ct values remained unchanged even after 72 h (Fig. 1C). Interestingly, for samples frozen at −30 °C and thawed, antigen titers decreased (Fig. 1C), whereas Ct values remained unchanged (Fig. 1D).

Effects of specimen storage methods and freezing and thawing on culture tests

Fig. 2 shows the comparison of virus titers before freezing and after freezing and thawing in various storage solutions. When nasopharyngeal swab specimens were stored in CELLBANKER®, the infectious titers were unaffected; however, when stored in saline, the infectious titers decreased after freezing and thawing. Freezing and thawing of saliva samples also reduced infectious titers in culture tests.
Fig. 2

Changes in culture virus titer before and after freezing and thawing.

Changes in culture virus titer before and after freezing and thawing. Our results highlight the vulnerability of saliva samples to freezing and thawing. Although saliva was inferior to CELLBANKER® as preservation media, it maintained higher antigen titers than saline did. However, when the specimens were frozen and thawed, the titers decreased. Additionally, virus titers in the cultures may also decrease compared to that before freezing. Notably, freezing and thawing of saliva specimens may result in false negative results in antigen and culture tests. The epitope recognized by LUMIPULSE® is speculated to be on the virus surface envelope. Therefore, freezing and thawing saliva degrades the epitope. We also found that saliva can be preserved for at least 72 h in AT or 4 °C. Contrastingly, the Ct value detected using PCR remained the same across all preservation conditions. Our study has several limitations. First, the sample size is small due to the limited volume of cases at early phase of the disease, wherein the viral load and infectiousness quotient is high. This is because government policy demands suspected patients to either stay home or move into accommodation facilities after disease onset. It was difficult to collect nasopharyngeal swab specimens with positive viral cultures, because our institution recommended testing saliva specimens, and we were not able to match the number of both specimens. Second, there is the issue of heterogeneity of saliva as a medium. Salivary adulterants vary greatly among individuals, and the effect of freezing and thawing may also vary greatly among individuals. In fact, we found that the antigen titer decreased in saliva1 even before freezing. Despite the limitations, the findings may greatly benefit clinical setting scenarios where antigen testing for COVID-19 cannot be performed immediately. Future studies must further investigate better storage solutions for saliva specimens.

Declaration of Competing Interest

The authors declare that they have no competing interests.
  7 in total

1.  Mass Screening of Asymptomatic Persons for Severe Acute Respiratory Syndrome Coronavirus 2 Using Saliva.

Authors:  Isao Yokota; Peter Y Shane; Kazufumi Okada; Yoko Unoki; Yichi Yang; Tasuku Inao; Kentaro Sakamaki; Sumio Iwasaki; Kasumi Hayasaka; Junichi Sugita; Mutsumi Nishida; Shinichi Fujisawa; Takanori Teshima
Journal:  Clin Infect Dis       Date:  2021-08-02       Impact factor: 9.079

2.  Older age is associated with sustained detection of SARS-CoV-2 in nasopharyngeal swab samples.

Authors:  Takeshi Hattori; Masaru Amishima; Daisuke Morinaga; Keisuke Kamada; Sho Nakakubo; Yu Yamashita; Yasuo Shichinohe; Shinichi Fujisawa; Mutsumi Nishida; Yasuyuki Nasuhara; Takanori Teshima; Satoshi Konno
Journal:  J Infect       Date:  2020-06-21       Impact factor: 6.072

3.  Comparison of SARS-CoV-2 detection in nasopharyngeal swab and saliva.

Authors:  Sumio Iwasaki; Shinichi Fujisawa; Sho Nakakubo; Keisuke Kamada; Yu Yamashita; Tatsuya Fukumoto; Kaori Sato; Satoshi Oguri; Keisuke Taki; Hajime Senjo; Junichi Sugita; Kasumi Hayasaka; Satoshi Konno; Mutsumi Nishida; Takanori Teshima
Journal:  J Infect       Date:  2020-06-04       Impact factor: 6.072

Review 4.  Saliva as a possible tool for the SARS-CoV-2 detection: A review.

Authors:  Régia Carla Medeiros da Silva; Liliane Cristina Nogueira Marinho; Davi Neto de Araújo Silva; Kenio Costa de Lima; Flavia Queiroz Pirih; Ana Rafaela Luz de Aquino Martins
Journal:  Travel Med Infect Dis       Date:  2020-11-19       Impact factor: 6.211

5.  Immunochromatography and chemiluminescent enzyme immunoassay for COVID-19 diagnosis.

Authors:  Toshiaki Ishii; Masakazu Sasaki; Kageto Yamada; Daiki Kato; Hiroyoshi Osuka; Kotaro Aoki; Toshisuke Morita; Yoshikazu Ishii; Kazuhiro Tateda
Journal:  J Infect Chemother       Date:  2021-02-25       Impact factor: 2.211

6.  Evaluation of Specimen Types and Saliva Stabilization Solutions for SARS-CoV-2 Testing.

Authors:  Sara B Griesemer; Greta Van Slyke; Dylan Ehrbar; Klemen Strle; Tugba Yildirim; Dominick A Centurioni; Anne C Walsh; Andrew K Chang; Michael J Waxman; Kirsten St George
Journal:  J Clin Microbiol       Date:  2021-04-20       Impact factor: 5.948

7.  Prospective study of 1308 nasopharyngeal swabs from 1033 patients using the LUMIPULSE SARS-CoV-2 antigen test: Comparison with RT-qPCR.

Authors:  Yosuke Hirotsu; Makoto Maejima; Masahiro Shibusawa; Kenji Amemiya; Yuki Nagakubo; Kazuhiro Hosaka; Hitomi Sueki; Miyoko Hayakawa; Hitoshi Mochizuki; Toshiharu Tsutsui; Yumiko Kakizaki; Yoshihiro Miyashita; Masao Omata
Journal:  Int J Infect Dis       Date:  2021-02-05       Impact factor: 3.623

  7 in total
  2 in total

1.  Boosting SARS-CoV-2 detection combining pooling and multiplex strategies.

Authors:  Isadora Alonso Correa; Tamires de Souza Rodrigues; Alex Queiroz; Leon de França Nascimento; Thiago Wolff; Rubens Nobumoto Akamine; Sergio Noboru Kuriyama; Luciana Jesus da Costa; Antonio Augusto Fidalgo-Neto
Journal:  Sci Rep       Date:  2022-05-23       Impact factor: 4.996

2.  High Diagnostic Accuracy of a Novel Lateral Flow Assay for the Point-of-Care Detection of SARS-CoV-2.

Authors:  Irene Giberti; Elisabetta Costa; Alexander Domnich; Valentina Ricucci; Vanessa De Pace; Giada Garzillo; Giulia Guarona; Giancarlo Icardi
Journal:  Biomedicines       Date:  2022-06-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.