Literature DB >> 33809581

Quantifying Step Count and Oxygen Consumption with Portable Technology during the 2-Min Walk Test in People with Lower Limb Amputation.

John D Smith1, Gary Guerra2.   

Abstract

Step counts and oxygen consumption have yet to be reported during the 2-min walk test (2MWT) test in persons with lower-limb amputations (LLA). The purpose of this study was to determine step counts and oxygen consumption during the 2MWT in LLA. Thirty-five men and women walked for two minutes as quickly as possible while wearing activity monitors (ActiGraph Link on the wrist (LW) and ankle (LA), Garmin vivofit®3 on the wrist (VW) and ankle (VA), and a modus StepWatch on the ankle (SA), and a portable oxygen analyzer. The StepWatch on the ankle (SA) and the vivofit3 on the wrist (VW) had the least error and best accuracy of the activity monitors studied. While there were no significant differences in distance walked, oxygen consumption (VO2) or heart rate (HR) between sexes or level of amputation (p > 0.05), females took significantly more steps than males (p = 0.034), and those with unilateral transfemoral amputations took significantly fewer steps than those with unilateral transtibial amputations (p = 0.023). The VW and SA provided the most accurate step counts among the activity monitors and were not significantly different than hand counts. Oxygen consumption for all participants during the 2MWT was 8.9 ± 2.9 mL/kg/min, which is lower than moderate-intensity activity. While some may argue that steady-state activity has not yet been reached in the 2MWT, it may also be possible participants are not walking as fast as they can, thereby misclassifying their performance to a lower standard.

Entities:  

Keywords:  2MWT; accelerometer; actigraphy; lower-limb prosthesis; metabolic cost; oxygen consumption; wearable activity monitors

Mesh:

Year:  2021        PMID: 33809581      PMCID: PMC7999204          DOI: 10.3390/s21062080

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  67 in total

1.  Functional outcome assessment of lower limb amputees and prosthetic users with a 2-minute walk test.

Authors:  Ljubinka Frlan-Vrgoc; Tea Schnurrer-Luke Vrbanić; Darko Kraguljac; Miljenko Kovacević
Journal:  Coll Antropol       Date:  2011-12

2.  Selecting a test for the clinical assessment of balance and walking capacity at the definitive fitting state after unilateral amputation: a comparative study.

Authors:  Vincent Gremeaux; Sabeur Damak; Odile Troisgros; Amine Feki; Davy Laroche; Dominic Perennou; Charles Benaim; Jean-Marie Casillas
Journal:  Prosthet Orthot Int       Date:  2012-03-02       Impact factor: 1.895

3.  An artificial gastrocnemius for a transtibial prosthesis.

Authors:  Ken Endo; Eric Swart; Hugh Herr
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

4.  Accuracy of the Actigraph wGT3x-BT for step counting during inpatient spinal cord rehabilitation.

Authors:  Erin Albaum; Emily Quinn; Saba Sedaghatkish; Parminder Singh; Amber Watkins; Kristin Musselman; Josh Williams
Journal:  Spinal Cord       Date:  2019-02-08       Impact factor: 2.772

5.  [Hospitalizations and amputations for diabetes mellitus-trends and small-area variation in Germany].

Authors:  Johannes Pollmanns; Maria Weyermann; Max Geraedts; Saskia E Drösler
Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz       Date:  2018-11       Impact factor: 1.513

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Reliability of outcome measures for people with lower-limb amputations: distinguishing true change from statistical error.

Authors:  Linda Resnik; Matthew Borgia
Journal:  Phys Ther       Date:  2011-02-10

8.  Use of a powered ankle-foot prosthesis reduces the metabolic cost of uphill walking and improves leg work symmetry in people with transtibial amputations.

Authors:  Jana R Montgomery; Alena M Grabowski
Journal:  J R Soc Interface       Date:  2018-08       Impact factor: 4.118

9.  Energy expenditure in people with transtibial amputation walking with crossover and energy storing prosthetic feet: A randomized within-subject study.

Authors:  Cody L McDonald; Patricia A Kramer; Sara J Morgan; Elizabeth G Halsne; Sarah M Cheever; Brian J Hafner
Journal:  Gait Posture       Date:  2018-03-27       Impact factor: 2.840

10.  Technology for monitoring everyday prosthesis use: a systematic review.

Authors:  Alix Chadwell; Laura Diment; M Micó-Amigo; Dafne Z Morgado Ramírez; Alex Dickinson; Malcolm Granat; Laurence Kenney; Sisary Kheng; Mohammad Sobuh; Robert Ssekitoleko; Peter Worsley
Journal:  J Neuroeng Rehabil       Date:  2020-07-14       Impact factor: 4.262

View more
  2 in total

1.  Accurate Step Count with Generalized and Personalized Deep Learning on Accelerometer Data.

Authors:  Long Luu; Arvind Pillai; Halsey Lea; Ruben Buendia; Faisal M Khan; Glynn Dennis
Journal:  Sensors (Basel)       Date:  2022-05-24       Impact factor: 3.847

2.  High-Level Mobility of Trans-Tibial Prosthesis Users Wearing Commercial and sPace Energy-Storing Prosthetic Feet.

Authors:  Thanyaporn Rakbangboon; Gary Guerra; Saloottra Kla-Arsa; Uthumporn Padungjaroen; Pairat Tangpornprasert; Chanyaphan Virulsri; Kazuhiko Sasaki
Journal:  Int J Environ Res Public Health       Date:  2022-10-02       Impact factor: 4.614

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.