This work concerns the performance analysis of the sensors contained in a victim detection system. The system is a mobile platform with gas sensors utilized for real time victim localization in urban environments after a disaster has caused the entrapment of people in partially collapsed building structures. The operating principle of the platform is the sampling of air from potential survival spaces (voids) and the measurement of the sampled air's temperature and concentration of CO2 and O2. Humans in a survival space are modelled as sources of CO2 and heat and sinks of O2. The physical openings of a survival space are modelled as sources of fresh air and sinks of the internal air. These sources and sinks dynamically affect the monitored properties of the air inside a survival space. In this paper, the effects of fresh air sources and internal air sinks are first examined in relation to local weather conditions. Then, the effect of human sources of CO2 and sinks of O2 in the space are examined. A model is formulated in order to reliably estimate the concentration of CO2 and O2 as a function of time for given reasonable entrapment scenarios. The input parameters are the local weather conditions, the openings of the survival space, and the number and type of entrapped humans. Three different tests successfully verified the presented theoretical estimations. A detection system with gas sensors of specified or measured capabilities, by utilizing this model and based on the expected concentrations, may inform the operator of the minimum required presence of humans in a survival space that can be detected after "some time".

Entities:  

Keywords:  air exchange; gas sensors; search and rescue; survivor detection

Mesh:

Substances:

Year:  2021        PMID: 33809293      PMCID: PMC7999499          DOI: 10.3390/s21062018

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  9 in total

1.  Transport abnormalities from single-breath dynamics of Ar, CO2 and O2.

Authors:  G M Saidel; J S Lin
Journal:  Respir Physiol       Date:  1986-06

2.  Normal respiratory rate and peripheral blood oxygen saturation in the elderly population.

Authors:  Alejandro Rodríguez-Molinero; Leire Narvaiza; Jorge Ruiz; César Gálvez-Barrón
Journal:  J Am Geriatr Soc       Date:  2013-12       Impact factor: 5.562

3.  [Development of the gaseous composition of air expired by man during quiet and forced respiration].

Authors:  D Colinet-Lagneaux; J Troquet
Journal:  Arch Int Physiol Biochim       Date:  1972-10

4.  Is everyone really breathing 20 times a minute? Assessing epidemiology and variation in recorded respiratory rate in hospitalised adults.

Authors:  Jack Badawy; Oanh Kieu Nguyen; Christopher Clark; Ethan A Halm; Anil N Makam
Journal:  BMJ Qual Saf       Date:  2017-06-26       Impact factor: 7.035

5.  The trapped human experiment.

Authors:  R Huo; A Agapiou; V Bocos-Bintintan; L J Brown; C Burns; C S Creaser; N A Devenport; B Gao-Lau; C Guallar-Hoyas; L Hildebrand; A Malkar; H J Martin; V H Moll; P Patel; A Ratiu; J C Reynolds; S Sielemann; R Slodzynski; M Statheropoulos; M A Turner; W Vautz; V E Wright; C L P Thomas
Journal:  J Breath Res       Date:  2011-09-12       Impact factor: 3.262

Review 6.  Normal ranges of heart rate and respiratory rate in children from birth to 18 years of age: a systematic review of observational studies.

Authors:  Susannah Fleming; Matthew Thompson; Richard Stevens; Carl Heneghan; Annette Plüddemann; Ian Maconochie; Lionel Tarassenko; David Mant
Journal:  Lancet       Date:  2011-03-19       Impact factor: 79.321

7.  Effect of changes in tidal volume on multiple breath washout outcomes.

Authors:  Felix Ratjen; Renee Jensen; Michelle Klingel; Reginald McDonald; Courtney Moore; Nick Benseler; David Wilson; Sanja Stanojevic
Journal:  PLoS One       Date:  2019-07-03       Impact factor: 3.240

8.  Characterizing microclimate in urban malaria transmission settings: a case study from Chennai, India.

Authors:  Lauren J Cator; Shalu Thomas; Krijn P Paaijmans; Sangamithra Ravishankaran; Johnson A Justin; Manu T Mathai; Andrew F Read; Matthew B Thomas; Alex Eapen
Journal:  Malar J       Date:  2013-03-02       Impact factor: 2.979

9.  Microclimate variables of the ambient environment deliver the actual estimates of the extrinsic incubation period of Plasmodium vivax and Plasmodium falciparum: a study from a malaria-endemic urban setting, Chennai in India.

Authors:  Shalu Thomas; Sangamithra Ravishankaran; N A Johnson Amala Justin; Aswin Asokan; T Maria Jusler Kalsingh; Manu Thomas Mathai; Neena Valecha; Jacqui Montgomery; Matthew B Thomas; Alex Eapen
Journal:  Malar J       Date:  2018-05-16       Impact factor: 2.979

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.