Literature DB >> 33802445

Multimodal Sensing Capabilities for the Detection of Shunt Failure.

Milenka Gamero1, Woo Seok Kim1, Sungcheol Hong1, Daniel Vorobiev1, Clinton D Morgan2, Sung Il Park1,3,4.   

Abstract

Hydrocephalus is a medical condition characterized by the abnormal accumulation of cerebrospinal fluid (CSF) within the cavities of the brain called ventricles. It frequently follows pediatric and adult congenital malformations, stroke, meningitis, aneurysmal rupture, brain tumors, and traumatic brain injury. CSF diversion devices, or shunts, have become the primary therapy for hydrocephalus treatment for nearly 60 years. However, routine treatment complications associated with a shunt device are infection, obstruction, and over drainage. Although some (regrettably, the minority) patients with shunts can go for years without complications, even those lucky few may potentially experience one shunt malfunction; a shunt complication can require emergency intervention. Here, we present a soft, wireless device that monitors distal terminal fluid flow and transmits measurements to a smartphone via a low-power Bluetooth communication when requested. The proposed multimodal sensing device enabled by flow sensors, for measurements of flow rate and electrodes for measurements of resistance in a fluidic chamber, allows precision measurement of CSF flow rate over a long time and under any circumstances caused by unexpected or abnormal events. A universal design compatible with any modern commercial spinal fluid shunt system would enable the widespread use of this technology.

Entities:  

Keywords:  multimodal sensors; pressure and flow rate; shunt device

Mesh:

Year:  2021        PMID: 33802445      PMCID: PMC7959456          DOI: 10.3390/s21051747

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  38 in total

1.  Evaluation of the ShuntCheck noninvasive thermal technique for shunt flow detection in hydrocephalic patients.

Authors:  Joseph R Madsen; Gani S Abazi; Laurel Fleming; Mark Proctor; Ron Grondin; Suresh Magge; Peter Casey; Tomer Anor
Journal:  Neurosurgery       Date:  2011-01       Impact factor: 4.654

Review 2.  Cerebrospinal Fluid Shunting Complications in Children.

Authors:  Brian W Hanak; Robert H Bonow; Carolyn A Harris; Samuel R Browd
Journal:  Pediatr Neurosurg       Date:  2017-03-02       Impact factor: 1.162

3.  Thermosensitive determination of patency in lumboperitoneal shunts. Technical note.

Authors:  Y Ishiwata; Y Chiba; T Yamashita; G Gondo; K Ide; T Kuwabara
Journal:  J Neurosurg       Date:  1989-01       Impact factor: 5.115

4.  Progressive tissue injury in infantile hydrocephalus and prevention/reversal with shunt treatment.

Authors:  H C Jones; N G Harris; J R Rocca; R W Andersohn
Journal:  Neurol Res       Date:  2000-01       Impact factor: 2.448

5.  Ultrathin Trilayer Assemblies as Long-Lived Barriers against Water and Ion Penetration in Flexible Bioelectronic Systems.

Authors:  Enming Song; Rui Li; Xin Jin; Haina Du; Yuming Huang; Jize Zhang; Yu Xia; Hui Fang; Yoon Kyeung Lee; Ki Jun Yu; Jan-Kai Chang; Yongfeng Mei; Muhammad A Alam; Yonggang Huang; John A Rogers
Journal:  ACS Nano       Date:  2018-10-05       Impact factor: 15.881

6.  Epidermal electronics for noninvasive, wireless, quantitative assessment of ventricular shunt function in patients with hydrocephalus.

Authors:  Siddharth R Krishnan; Tyler R Ray; Amit B Ayer; Yinji Ma; Philipp Gutruf; KunHyuck Lee; Jong Yoon Lee; Chen Wei; Xue Feng; Barry Ng; Zachary A Abecassis; Nikhil Murthy; Izabela Stankiewicz; Juliet Freudman; Julia Stillman; Natalie Kim; Grace Young; Camille Goudeseune; John Ciraldo; Matthew Tate; Yonggang Huang; Matthew Potts; John A Rogers
Journal:  Sci Transl Med       Date:  2018-10-31       Impact factor: 17.956

Review 7.  Genetics of human hydrocephalus.

Authors:  Jun Zhang; Michael A Williams; Daniele Rigamonti
Journal:  J Neurol       Date:  2006-06-13       Impact factor: 4.849

8.  Capacitive technologies for highly controlled and personalized electrical stimulation by implantable biomedical systems.

Authors:  Marco P Soares Dos Santos; J Coutinho; Ana Marote; Bárbara Sousa; A Ramos; Jorge A F Ferreira; Rodrigo Bernardo; André Rodrigues; A Torres Marques; Odete A B da Cruz E Silva; Edward P Furlani; José A O Simões; Sandra I Vieira
Journal:  Sci Rep       Date:  2019-03-21       Impact factor: 4.379

9.  A wireless closed-loop system for optogenetic peripheral neuromodulation.

Authors:  Aaron D Mickle; Sang Min Won; Kyung Nim Noh; Jangyeol Yoon; Kathleen W Meacham; Yeguang Xue; Lisa A McIlvried; Bryan A Copits; Vijay K Samineni; Kaitlyn E Crawford; Do Hoon Kim; Paulome Srivastava; Bong Hoon Kim; Seunghwan Min; Young Shiuan; Yeojeong Yun; Maria A Payne; Jianpeng Zhang; Hokyung Jang; Yuhang Li; H Henry Lai; Yonggang Huang; Sung-Il Park; Robert W Gereau; John A Rogers
Journal:  Nature       Date:  2019-01-02       Impact factor: 49.962

10.  Noninvasive thermal evaluation for shunt failure in the emergency room.

Authors:  Jordan Xu; Cassie Poole; Ronald Sahyouni; Jefferson Chen
Journal:  Surg Neurol Int       Date:  2019-12-27
View more