Literature DB >> 33800112

Efficacy of the XEN-Implant in Glaucoma and a Meta-Analysis of the Literature.

Huub J Poelman1, Jan Pals1, Parinaz Rostamzad1, Wichor M Bramer2, Roger C W Wolfs1, Wishal D Ramdas1.   

Abstract

BACKGROUND: To assess the efficacy of XEN-implant surgery in patients with glaucoma, and to perform a meta-analysis of previously published results and compare these to our data.
METHODS: Prospective case-control study, in which all eyes that underwent XEN-implant surgery were included from 2015 onwards. Sub-analyses were performed for eyes that underwent XEN-implant as standalone procedure and as cataract-combined procedure. To compare our results, a systematic review was performed using the Embase, PubMed, Web of Science, and Cochrane database. Meta-analyses were performed by combining data (intraocular pressure (IOP), IOP-lowering medication, and complications) from the retrieved studies.
RESULTS: A total of 221 eyes underwent XEN-implant surgery (124 standalone and 97 cataract-combined). The mean ± standard deviation IOP declined from 18.8 ± 6.5 to 13.5 ± 4.3 mmHg at the last follow-up (p < 0.001; 28.9%). Postoperative, no significant differences in IOP or IOP-lowering medication were found between patients with and without combined procedure. Secondary surgeries were performed in 20.8% of eyes, most of them (63.0%) within six months. A meta-analysis of 19 studies retrieved from the systematic review showed a two-years postoperative pooled mean (weighted mean difference) of 14.5 (7.3) mmHg and 1.0 (1.6) for IOP and IOP-lowering medications, respectively (compared to 13.5 (5.3) mmHg and 3.2 (2.4) in the current study).
CONCLUSION: XEN-implant surgery was effective and safe in lowering IOP and the number of IOP-lowering medications. There were no differences between standalone and combined procedures.

Entities:  

Keywords:  IOP-lowering medication; XEN-implant; XEN45; gelatin stent; glaucoma; intraocular pressure

Year:  2021        PMID: 33800112      PMCID: PMC7962186          DOI: 10.3390/jcm10051118

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  32 in total

1.  Minimally invasive combined glaucoma and cataract surgery: clinical results of the smallest ab interno gel stent.

Authors:  Alessandra De Gregorio; Emilio Pedrotti; Luisa Russo; Simonetta Morselli
Journal:  Int Ophthalmol       Date:  2017-05-29       Impact factor: 2.031

2.  A Retrospective Study of 199 Xen45 Stent Implantations From 2014 to 2016.

Authors:  Astrid Heidinger; Christoph Schwab; Ewald Lindner; Regina Riedl; Georg Mossböck
Journal:  J Glaucoma       Date:  2019-01       Impact factor: 2.503

3.  The XEN45 Gel Stent as a minimally invasive procedure in glaucoma surgery: success rates, risk profile, and rates of re-surgery after 261 surgeries.

Authors:  Randolf A Widder; Thomas S Dietlein; Sven Dinslage; Pia Kühnrich; Corinna Rennings; Gernot Rössler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-01-22       Impact factor: 3.117

Review 4.  Implantable drainage devices in glaucoma: Quo vadis?

Authors:  Khushwant S Yadav; Sushmita Sharma
Journal:  Eur J Pharm Sci       Date:  2019-03-12       Impact factor: 4.384

5.  One-year result of XEN45 implant for glaucoma: efficacy, safety, and postoperative management.

Authors:  S Z Tan; A Walkden; L Au
Journal:  Eye (Lond)       Date:  2017-09-01       Impact factor: 3.775

6.  European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma.

Authors:  Antonio M Fea; Alain M Bron; Mario A Economou; Gianluca Laffi; Enrico Martini; Michele Figus; Francesco Oddone
Journal:  J Cataract Refract Surg       Date:  2020-03       Impact factor: 3.351

7.  XEN® Gel Stent compared to PRESERFLO™ MicroShunt implantation for primary open-angle glaucoma: two-year results.

Authors:  Lotte M J Scheres; Stefani Kujovic-Aleksov; Wishal D Ramdas; Ronald M P C de Crom; Lianne C G Roelofs; Tos T J M Berendschot; Carroll A B Webers; Henny J M Beckers
Journal:  Acta Ophthalmol       Date:  2020-09-10       Impact factor: 3.761

Review 8.  Efficacy of glaucoma drainage devices in uveitic glaucoma and a meta-analysis of the literature.

Authors:  Wishal D Ramdas; Jan Pals; Aniki Rothova; Roger C W Wolfs
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-10-11       Impact factor: 3.117

9.  Comparison of Minimally Invasive XEN45 Gel Stent Implantation in Glaucoma Patients Without and With Prior Interventional Therapies.

Authors:  Fritz H Hengerer; Gerd Auffarth; Ina Conrad-Hengerer
Journal:  Ophthalmol Ther       Date:  2019-06-13

10.  Two-year outcomes of minimally invasive XEN Gel Stent implantation in primary open-angle and pseudoexfoliation glaucoma.

Authors:  Teresa Rauchegger; Reinhard Angermann; Peter Willeit; Eduard Schmid; Barbara Teuchner
Journal:  Acta Ophthalmol       Date:  2020-09-30       Impact factor: 3.761

View more
  4 in total

1.  Efficacy and Safety of Micropulse Transscleral Cyclophotocoagulation.

Authors:  Victor A de Vries; Jan Pals; Huub J Poelman; Parinaz Rostamzad; Roger C W Wolfs; Wishal D Ramdas
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

2.  The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis.

Authors:  Xiang Yang; Yang Zhao; Yu Zhong; Xuanchu Duan
Journal:  BMC Ophthalmol       Date:  2022-07-15       Impact factor: 2.086

3.  Clinical outcomes of combined Preserflo Microshunt implantation and cataract surgery in open-angle glaucoma patients.

Authors:  José M Martínez-de-la-Casa; Federico Saenz-Francés; Laura Morales-Fernandez; Lucia Perucho; Carmen Mendez; Ana Fernandez-Vidal; Sofía Garcia-Saenz; Ruben Sanchez-Jean; Julian García-Feijoo
Journal:  Sci Rep       Date:  2021-08-02       Impact factor: 4.379

4.  Special Issue "Recommendations for Clinical Management of Glaucoma".

Authors:  Paolo Fogagnolo
Journal:  J Clin Med       Date:  2022-03-09       Impact factor: 4.241

  4 in total