Literature DB >> 3379208

The echo-transponder electrode catheter: a new method for mapping the left ventricle.

J J Langberg1, J O Franklin, J S Landzberg, J M Herre, L Kee, M C Chin, S Bharati, M Lev, R B Himelman, N B Schiller.   

Abstract

The ability to locate catheter position in the left ventricle with respect to endocardial landmarks might enhance the accuracy of ventricular tachycardia mapping. An echo-transponder system (Telectronics, Inc.) was compared with biplane fluoroscopy for left ventricular endocardial mapping. A 6F electrode catheter was modified with the addition of a piezoelectric crystal 5 mm from the tip. This crystal was connected to a transponder that received and transmitted ultrasound, resulting in a discrete artifact on the two-dimensional echocardiographic image corresponding to the position of the catheter tip. Catheters were introduced percutaneously into the left ventricle of nine anesthetized dogs. Two-dimensional echo-transponder and biplane fluoroscopic images were recorded on videotape with the catheter at multiple endocardial sites. Catheter location was marked by delivering radiofrequency current to the distal electrode, creating a small endocardial lesion. Catheter location by echo-transponder and by fluoroscopy were compared with lesion location without knowledge of other data. Location by echo-transponder was 8.7 +/- 5.1 mm from the center of the radiofrequency lesion versus 14 + 7.8 mm by fluoroscopy (n = 15, p = 0.023). Echo-transponder localization is more precise than is biplane fluoroscopy and may enhance the accuracy of left ventricular electrophysiologic mapping.

Entities:  

Mesh:

Year:  1988        PMID: 3379208     DOI: 10.1016/0735-1097(88)90377-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  5 in total

1.  Accurate guidance of a catheter by ultrasound imaging and identification of a catheter tip by pulsed-wave Doppler.

Authors:  Eileen M McMahon; Panupong Jiamsripong; Minako Katayama; Hari P Chaliki; Mostafa Fatemi; Marek Belohlavek
Journal:  Pacing Clin Electrophysiol       Date:  2011-11-06       Impact factor: 1.976

2.  A Real-time Color Doppler Marker for Echocardiographic Guidance of an Acoustically Active Extracorporeal Membrane Oxygenation Cannula.

Authors:  Marek Belohlavek; Minako Katayama; Veronica V Vaitkus; Viksit Kumar; Mostafa Fatemi; Jason Grabham; Bryan Sandweiss
Journal:  J Ultrasound Med       Date:  2018-11-12       Impact factor: 2.153

3.  Acoustically Active Catheter for Intracardiac Navigation by Color Doppler Ultrasonography.

Authors:  Minako Katayama; David Zarbatany; Stephen S Cha; Mostafa Fatemi; Marek Belohlavek
Journal:  Ultrasound Med Biol       Date:  2017-06-05       Impact factor: 2.998

4.  Acoustically active injection catheter guided by ultrasound: navigation tests in acutely ischemic porcine hearts.

Authors:  Marek Belohlavek; Minako Katayama; David Zarbatany; F David Fortuin; Mostafa Fatemi; Ivan Z Nenadic; Eileen M McMahon
Journal:  Ultrasound Med Biol       Date:  2014-04-27       Impact factor: 2.998

5.  Echocardiographic transponder-guided catheter ablation feasibility and accuracy.

Authors:  V Menz; D Vilkomerson; J F Ren; J J Michele; D Schwartzman
Journal:  J Interv Card Electrophysiol       Date:  2001-06       Impact factor: 1.900

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.