Bulb Cannula Safety for Breast Fat Grafting.

Marcos Sforza1, Nicole Martinez2, Nathalia Araujo3, Roberto de Mezerville4, Jose Andrés Castro5.   

Abstract

Autologous fat transfer is a common technique to refine the contour of the breast after prosthetic augmentation or reconstruction, correcting remaining asymmetries by injecting previously harvested fat tissue with a cannula. Current procedures are often performed without visualization of the cannula at the delivery site and may require subsequent verification of the implant's integrity. The present paper aims to evaluate the safety of a new bulb tip cannula to be used during breast implant procedures for injecting fat adjacent to a breast implant that reduce the risk of damaging the implant. Two conventional cannulae and 3 bulb cannulae, which have an atraumatic distal tip, were tested in a simulated implant-puncture setting in 3 positions (at 0°, 45°, and 90° of incidence). A Tensile Tester (Instron, High Wycombe, UK) was used to apply force with each cannula device and record the amount of force applied in the attempt to penetrate the implants used, with shell layers having a variable thickness. No implant rupture was observed with the bulb tip cannulae regardless of size or the position in which the cannulae were pressed against the implants. The cannula opening was not impeded and tended to bend instead; 27% of the cases with the conventional lipo-cannulae caused an implant rupture. The bulb tip cannula could enhance the safety of the fat transfer procedure by ensuring no iatrogenic implant disruption and optimal delivery of the fat tissue.
© 2020 The American Society for Aesthetic Plastic Surgery, Inc.

Entities:  

Year:  2020        PMID: 33791641      PMCID: PMC7780445          DOI: 10.1093/asjof/ojaa014

Source DB:  PubMed          Journal:  Aesthet Surg J Open Forum        ISSN: 2631-4797


  6 in total

1.  The American Society for Aesthetic Plastic Surgery's Cosmetic Surgery National Data Bank: Statistics 2018.

Authors: 
Journal:  Aesthet Surg J       Date:  2019-06-21       Impact factor: 4.283

2.  A Preliminary Assessment of the Predictability of Fat Grafting to Correct Silicone Breast Implant-Related Complications.

Authors:  Marcos Sforza; Katarina Andjelkov; Renato Zaccheddu; Rodwan Husein; Connor Atkinson
Journal:  Aesthet Surg J       Date:  2016-05-07       Impact factor: 4.283

3.  Stereoscopic Analysis of Silicone Breast Implant Shells Damaged by Surgical Instruments.

Authors:  Derek A Rapp; Keith C Neaman; Dennis C Hammond
Journal:  Plast Reconstr Surg       Date:  2015-07       Impact factor: 4.730

4.  Outcomes of Prosthetic Reconstruction of Irradiated and Nonirradiated Breasts with Fat Grafting.

Authors:  Ewa Komorowska-Timek; Zaahir Turfe; Alan T Davis
Journal:  Plast Reconstr Surg       Date:  2017-01       Impact factor: 4.730

5.  Nanotechnology, nanosurfaces and silicone gel breast implants: current aspects.

Authors:  Alexandre Mendonça Munhoz; Fabio Santanelli di Pompeo; Roberto De Mezerville
Journal:  Case Reports Plast Surg Hand Surg       Date:  2017-11-29

6.  Preliminary 3-Year Evaluation of Experience With SilkSurface and VelvetSurface Motiva Silicone Breast Implants: A Single-Center Experience With 5813 Consecutive Breast Augmentation Cases.

Authors:  Marcos Sforza; Renato Zaccheddu; Angelo Alleruzzo; Adriano Seno; Domenico Mileto; Arnaldo Paganelli; Hassan Sulaiman; Michael Payne; Lajos Maurovich-Horvat
Journal:  Aesthet Surg J       Date:  2018-05-15       Impact factor: 4.283

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.