Literature DB >> 27155193

A Preliminary Assessment of the Predictability of Fat Grafting to Correct Silicone Breast Implant-Related Complications.

Marcos Sforza, Katarina Andjelkov, Renato Zaccheddu, Rodwan Husein, Connor Atkinson.   

Abstract

BACKGROUND: Fat grafting in breast augmentation surgery is becoming increasingly popular and is allowing surgeons to fill the gaps that implant augmentation alone cannot. However, one current issue surrounding fat grafting is resorption.
OBJECTIVES: In this prospective study, the authors present their experience of fat grafting and resorption in 26 patients who had fat transfer to correct deformities or asymmetries following primary breast enlargement surgery.
METHODS: The fat utilized was harvested and processed using the Puregraft system. Fat grafting was performed until the problem was visually corrected, followed by an additional 30% overcorrection. Photographs were taken preoperatively and 1 year postoperatively, and analyzed utilizing cloud-based 3-dimensional imaging software to measure the breast volumes and calculate 1-year resorption rates. Both patients and physicians were asked to rate their satisfaction.
RESULTS: The total volume of fat transferred ranged from 160 cc to 360 cc, with an average of 280 cc per procedure. The absolute volume of tissue resorption showed considerable variation (median, 42.6 mL; range, 5.5-62 mL). However, there was a very close correlation between the volume resorbed and the volume implanted: the more volume injected, the more volume absorbed. When expressed as a percentage of implanted tissue, the resorption rate was 27.5 ± 0.8% (mean ± standard deviation) with a very narrow range (25.7%-28.9%). Patients and physicians reported a satisfaction rate of "excellent" in 83.3% and 75% of cases, respectively.
CONCLUSIONS: At 1 year, 25.7% to 28.9% of the injected fat had been resorbed in a predictable, reproducible, and effective manner. LEVEL OF EVIDENCE: 4 Therapeutic.
© 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27155193     DOI: 10.1093/asj/sjw060

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


  4 in total

1.  Optimizing Surgical Outcomes with Small-Volume Silicone Implants Associated with Autogenous Fat Grafting in Primary and Revision Breast Augmentation Surgery: Soft Weight Hybrid (SWEH) Concept.

Authors:  Alexandre Mendonça Munhoz; Ary de Azevedo Marques Neto; João Maximiliano
Journal:  Aesthetic Plast Surg       Date:  2021-11-30       Impact factor: 2.708

2.  Expert Consensus on the Use of a New Bioengineered, Cell-Friendly, Smooth Surface Breast Implant.

Authors:  Marcos Sforza; Dennis C Hammond; Giovanni Botti; Per Hedén; Manuel Chacón Quirós; Alexandre Mendonça Munhoz; Brian M Kinney; Niamh Corduff
Journal:  Aesthet Surg J       Date:  2019-04-08       Impact factor: 4.283

3.  Bulb Cannula Safety for Breast Fat Grafting.

Authors:  Marcos Sforza; Nicole Martinez; Nathalia Araujo; Roberto de Mezerville; Jose Andrés Castro
Journal:  Aesthet Surg J Open Forum       Date:  2020-04-13

Review 4.  Cell-Assisted Lipotransfer in Breast Augmentation Surgery: Clinical Outcomes and Considerations for Future Research.

Authors:  Dimitrios Asimakopoulos; John M Anastasatos
Journal:  Cureus       Date:  2022-03-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.