Literature DB >> 33772969

Anorectal manometry to diagnose dyssynergic defecation: Systematic review and meta-analysis of diagnostic test accuracy.

Alexandra R Ortengren1, Resham A Ramkissoon1, William D Chey2, Jason R Baker2, Kyle Staller3, Johanna Iturrino4, Eric D Shah1.   

Abstract

BACKGROUND: Chronic constipation is a common condition, and dyssynergic defecation underlies up to 40% of cases. Anorectal manometry is recommended to assess for dyssynergic defecation among chronically constipated patients but remains poorly standardized. We aimed to evaluate the diagnostic accuracy of anorectal manometry and determine optimal testing parameters.
METHODS: We performed a systematic review with meta-analysis of diagnostic test accuracy including cohort studies of chronically constipated patients and case-control studies of patients with dyssynergic defecation or healthy controls. Meta-analysis was performed to determine summary sensitivity, specificity, and area under the curve (AUC) with 95% confidence intervals (CI). KEY
RESULTS: A total of 15 studies comprising 2140 patients were included. Including all studies (estimating optimal diagnostic accuracy), the AUC was 0.78 [95% CI 0.72-0.82], summary sensitivity was 79% [61%-90%], and summary specificity was 64% [44%-79%] to diagnose dyssynergic defecation. In cohort studies only (estimating real-world diagnostic accuracy), the AUC was 0.72 [0.66-0.77], summary sensitivity was 86% [64%-95%], and summary specificity was 49% [30%-68%]. Employing three consecutive simulated defecation attempts improved sensitivity to 94%. A fourth simulated defecation maneuver with air insufflation may improve accuracy. Measuring anorectal pressures to identify complex dyssynergic patterns did not improve real-world diagnostic accuracy estimates over anal pressure measurement alone. Choice of manometry system did not impact diagnostic accuracy. CONCLUSIONS & INFERENCES: Following the current iteration of the London consensus protocol (three simulated defecation attempts measuring anal relaxation), the role of anorectal manometry in evaluating dyssynergic defecation appears limited. Future iterations of this protocol may improve diagnostic accuracy.
© 2021 John Wiley & Sons Ltd.

Entities:  

Keywords:  balloon expulsion testing; diagnostic test performance; dyssynergic defecation; outlet dysfunction constipation

Mesh:

Year:  2021        PMID: 33772969     DOI: 10.1111/nmo.14137

Source DB:  PubMed          Journal:  Neurogastroenterol Motil        ISSN: 1350-1925            Impact factor:   3.598


  2 in total

1.  Development of a Simple, Point-of-Care Device to Test Anorectal Function in Patients with Constipation: Randomized Clinical Trial.

Authors:  William D Chey; Jason R Baker; Lydia Watts; Adrienne Harris; Eric D Shah
Journal:  Clin Gastroenterol Hepatol       Date:  2021-12-02       Impact factor: 13.576

Review 2.  Functional Constipation and Dyssynergic Defecation in Children.

Authors:  Ilan J N Koppen; Marc A Benninga
Journal:  Front Pediatr       Date:  2022-02-16       Impact factor: 3.418

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.