Literature DB >> 33744605

A systematic approach to development of analytical scale and microflow-based liquid chromatography coupled to mass spectrometry metabolomics methods to support drug discovery and development.

Sarah Geller1, Harvey Lieberman1, Alla Kloss1, Alexander R Ivanov2.   

Abstract

As the reliance on metabolic biomarkers within drug discovery and development increases, there is also an increased demand for global metabolomics methods to provide broad metabolome coverage and sensitivity towards differences in metabolite expression and reproducibility. A systematic approach is necessary for the development, and evaluation, of metabolomics methods using either conventional techniques or when establishing new methods that allow for additional gains in sensitivity and a reduction in requirements for amounts of a biological sample, such as those seen with methods based on microseparations. We developed a novel standard mixture and used a systematic approach for the development and optimization of optimal, ion-pair free, liquid chromatography-mass spectrometry (LC-MS) global profiling methods. These methods were scaled-down to microflow-based LC separations and compared with analytical flow ion-pairing reagent containing methods. Average peak volume improvements of 7- and 22-fold were observed in the positive and negative ionization mode microflow methods as compared to the ion-pairing reagent analytical flow methods, respectively. The linear range of the newly developed microflow methods showed up to a 10-fold increase in the lower limit of detection in the negative ionization mode. The developed microflow LC-MS methods were further evaluated using wild-type mouse plasma where up to a 9-fold increase in peak volume was observed.
Copyright © 2021. Published by Elsevier B.V.

Entities:  

Keywords:  Increased sensitivity in metabolomics; LC-MS; Metabolic profiling; Metabolomics; Microbore columns; Microflow LC

Mesh:

Year:  2021        PMID: 33744605      PMCID: PMC8035295          DOI: 10.1016/j.chroma.2021.462047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  56 in total

1.  Gas chromatography-mass spectrometry (GC-MS)-based metabolomics.

Authors:  Antonia Garcia; Coral Barbas
Journal:  Methods Mol Biol       Date:  2011

2.  An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry.

Authors:  Emma L Harry; Daniel J Weston; Anthony W T Bristow; Ian D Wilson; Colin S Creaser
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-05-08       Impact factor: 3.205

Review 3.  Hydrophilic interaction chromatography coupled to MS for metabonomic/metabolomic studies.

Authors:  Konstantina Spagou; Helen Tsoukali; Nikolaos Raikos; Helen Gika; Ian D Wilson; Georgios Theodoridis
Journal:  J Sep Sci       Date:  2010-03       Impact factor: 3.645

Review 4.  Recent advances in capillary ultrahigh pressure liquid chromatography.

Authors:  Laura E Blue; Edward G Franklin; Justin M Godinho; James P Grinias; Kaitlin M Grinias; Daniel B Lunn; Stephanie M Moore
Journal:  J Chromatogr A       Date:  2017-05-17       Impact factor: 4.759

Review 5.  NMR and pattern recognition methods in metabolomics: from data acquisition to biomarker discovery: a review.

Authors:  Agnieszka Smolinska; Lionel Blanchet; Lutgarde M C Buydens; Sybren S Wijmenga
Journal:  Anal Chim Acta       Date:  2012-06-09       Impact factor: 6.558

Review 6.  Multidimensional NMR approaches towards highly resolved, sensitive and high-throughput quantitative metabolomics.

Authors:  Jérémy Marchand; Estelle Martineau; Yann Guitton; Gaud Dervilly-Pinel; Patrick Giraudeau
Journal:  Curr Opin Biotechnol       Date:  2016-09-14       Impact factor: 9.740

Review 7.  Emerging applications of metabolomics in drug discovery and precision medicine.

Authors:  David S Wishart
Journal:  Nat Rev Drug Discov       Date:  2016-03-11       Impact factor: 84.694

Review 8.  Innovation: Metabolomics: the apogee of the omics trilogy.

Authors:  Gary J Patti; Oscar Yanes; Gary Siuzdak
Journal:  Nat Rev Mol Cell Biol       Date:  2012-03-22       Impact factor: 94.444

Review 9.  Silica, hybrid silica, hydride silica and non-silica stationary phases for liquid chromatography.

Authors:  Endler M Borges
Journal:  J Chromatogr Sci       Date:  2014-09-18       Impact factor: 1.618

10.  Effects of ion-pairing reagents on the electrospray signal suppression of sulphonated dyes and intermediates.

Authors:  M Holcapek; K Volná; P Jandera; L Kolárová; K Lemr; M Exner; A Církva
Journal:  J Mass Spectrom       Date:  2004-01       Impact factor: 1.982

View more
  1 in total

1.  Comparison of Microflow and Analytical Flow Liquid Chromatography Coupled to Mass Spectrometry Global Metabolomics Methods Using a Urea Cycle Disorder Mouse Model.

Authors:  Sarah Geller; Harvey Lieberman; Adam J Belanger; Nelson S Yew; Alla Kloss; Alexander R Ivanov
Journal:  J Proteome Res       Date:  2021-11-29       Impact factor: 4.466

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.