Thoracic Fluid Content (TFC) Measurement Using Impedance Cardiography Predicts Outcomes in Critically Ill Children.

Lydia Sumbel1, Aanchal Wats1, Mohammed Salameh1,2, Elumalai Appachi1,2, Utpal Bhalala1,2.   

Abstract

Objective: Conventional methods of fluid assessment in critically ill children are difficult and/or inaccurate. Impedance cardiography has capability of measuring thoracic fluid content (TFC). There is an insufficient literature reporting correlation between TFC and conventional methods of fluid balance and whether TFC predicts outcomes in critically ill children. We hypothesized that TFC correlates with indices of fluid balance [FIMO (Fluid Intake Minus Output) and AFIMO (Adjusted Fluid Intake Minus Output)] and is a predictor of outcomes in critically ill children. Design: Retrospective chart review. Setting: Pediatric intensive care unit of a tertiary care teaching hospital. Patients: Children <21 years, admitted to our Pediatric Intensive Care Unit (PICU) between July- November 2018 with acute respiratory failure and/or shock and who were monitored for fluid status using ICON® monitor. Interventions: None. Measurements and Main
Results: We collected demographic information, data on daily and cumulative fluid balance (CFB), ventilator, PICU and hospital days, occurrence of multi-organ dysfunction syndrome (MODS), and mortality. We calculated AFIMO using insensible fluid loss. We analyzed data using correlation coefficient, chi-square test and multiple linear regression analysis. We analyzed a total 327 recordings of TFC, FIMO and AFIMO as daily records of fluid balance in 61 critically ill children during the study period. The initial TFC, FIMO, and AFIMO in ml [median (IQR)] were 30(23, 44), 300(268, 325), and 21.05(-171.3, 240.2), respectively. The peak TFC, FIMO, and AFIMO in ml were 36(26, 24), 322(286, 334), and 108.8(-143.6, 324.4) respectively. The initial CFB was 1134.2(325.6, 2774.4). TFC did not correlate well with FIMO or AFIMO (correlation coefficient of 0.02 and -0.03, respectively), but a significant proportion of patients with high TFC exhibited pulmonary plethora on x-ray chest (as defined by increased bronchovascular markings and/or presence of pleural effusion) (p = 0.015). The multiple linear regression analysis revealed that initial and peak TFC and peak and mean FIMO and AFIMO predicted outcomes (ventilator days, length of PICU, and hospital days) in critically ill children (p < 0.05). Conclusions: In our cohort of critically ill children with respiratory failure and/or shock, TFC did not correlate with conventional measures of fluid balance (FIMO/AFIMO), but a significant proportion of patients with high TFC had pulmonary plethora on chest x-ray. Both initial and peak TFC predicted outcomes in critically ill children.
Copyright © 2021 Sumbel, Wats, Salameh, Appachi and Bhalala.

Entities:  

Keywords:  children; fluid balance; fluid overload; impedance cardiography; outcomes

Year:  2021        PMID: 33718292      PMCID: PMC7947197          DOI: 10.3389/fped.2020.564902

Source DB:  PubMed          Journal:  Front Pediatr        ISSN: 2296-2360            Impact factor:   3.418


  39 in total

1.  Early goal-directed therapy in the treatment of severe sepsis and septic shock.

Authors:  E Rivers; B Nguyen; S Havstad; J Ressler; A Muzzin; B Knoblich; E Peterson; M Tomlanovich
Journal:  N Engl J Med       Date:  2001-11-08       Impact factor: 91.245

Review 2.  Measurement of thoracic fluid content in heart failure: the role of impedance cardiography.

Authors:  Lynn Folan; Marjorie Funk
Journal:  AACN Adv Crit Care       Date:  2008 Jan-Mar

Review 3.  Clinical practice parameters for hemodynamic support of pediatric and neonatal patients in septic shock.

Authors:  Joseph A Carcillo; Alan I Fields
Journal:  Crit Care Med       Date:  2002-06       Impact factor: 7.598

4.  Fluid Overload Is Associated With Late Poor Outcomes in Neonates Following Cardiac Surgery.

Authors:  Nicole S Wilder; Sunkyung Yu; Janet E Donohue; Caren S Goldberg; Neal B Blatt
Journal:  Pediatr Crit Care Med       Date:  2016-05       Impact factor: 3.624

5.  Outcome of pediatric patients with multiple organ system failure.

Authors:  J D Wilkinson; M M Pollack; U E Ruttimann; N L Glass; T S Yeh
Journal:  Crit Care Med       Date:  1986-04       Impact factor: 7.598

6.  Fluid overload and mortality in children receiving continuous renal replacement therapy: the prospective pediatric continuous renal replacement therapy registry.

Authors:  Scott M Sutherland; Michael Zappitelli; Steven R Alexander; Annabelle N Chua; Patrick D Brophy; Timothy E Bunchman; Richard Hackbarth; Michael J G Somers; Michelle Baum; Jordan M Symons; Francisco X Flores; Mark Benfield; David Askenazi; Deepa Chand; James D Fortenberry; John D Mahan; Kevin McBryde; Douglas Blowey; Stuart L Goldstein
Journal:  Am J Kidney Dis       Date:  2009-12-30       Impact factor: 8.860

7.  Impedance cardiography: the next vital sign technology?

Authors:  Joseph M Van De Water; Timothy W Miller; Robert L Vogel; Bruce E Mount; Martin L Dalton
Journal:  Chest       Date:  2003-06       Impact factor: 9.410

8.  Extent, risk factors, and outcome of fluid overload after pediatric heart surgery*.

Authors:  Jade Seguin; Benjamin Albright; Laura Vertullo; Pamela Lai; Adrian Dancea; Pierre-Luc Bernier; Christo I Tchervenkov; Christos Calaritis; David Drullinsky; Ronald Gottesman; Michael Zappitelli
Journal:  Crit Care Med       Date:  2014-12       Impact factor: 7.598

9.  Positive fluid balance is associated with higher mortality and prolonged mechanical ventilation in pediatric patients with acute lung injury.

Authors:  Heidi R Flori; Gwynne Church; Kathleen D Liu; Ginny Gildengorin; Michael A Matthay
Journal:  Crit Care Res Pract       Date:  2011-05-29

10.  Comparison of three non-invasive hemodynamic monitoring methods in critically ill children.

Authors:  Chanapai Chaiyakulsil; Marut Chantra; Poomiporn Katanyuwong; Anant Khositseth; Nattachai Anantasit
Journal:  PLoS One       Date:  2018-06-18       Impact factor: 3.240

View more
  2 in total

1.  Tools for assessing lung fluid in neonates with respiratory distress.

Authors:  So Jin Yoon; Jung Ho Han; Kee Hyun Cho; Joonsik Park; Soon Min Lee; Min Soo Park
Journal:  BMC Pediatr       Date:  2022-06-20       Impact factor: 2.567

2.  Non-invasive Cardiac Output Monitoring and Assessment of Fluid Responsiveness in Children With Shock in the Emergency Department.

Authors:  Pranali Awadhare; Radha Patel; Tracy McCallin; Kiran Mainali; Kelly Jackson; Hannah Starke; Utpal Bhalala
Journal:  Front Pediatr       Date:  2022-04-07       Impact factor: 3.569

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.