Literature DB >> 18418105

Measurement of thoracic fluid content in heart failure: the role of impedance cardiography.

Lynn Folan1, Marjorie Funk.   

Abstract

Current guidelines for assessing the fluid status of patients with heart failure include subjective physical findings, which often occur late in decompensation, and objective pulmonary artery catheter measurements, whose use is controversial in patients with heart failure. Impedance cardiography, which assesses cardiac function by measuring the opposition to an alternating electric current in the thorax, indicates the amount of fluid in the thorax. It is used externally by employing electrodes on the thorax but can also be used internally by electrodes within a cardiac pacemaker. Recent studies have suggested that one of its direct measurements, thoracic impedance, may identify patients at risk for decompensation of heart failure, but because these measurements inconsistently correlate with pulmonary artery catheter measurements and study sample sizes are small, further research is required before its use can be recommended.

Entities:  

Mesh:

Year:  2008        PMID: 18418105     DOI: 10.1097/01.AACN.0000310751.93287.42

Source DB:  PubMed          Journal:  AACN Adv Crit Care        ISSN: 1559-7768


  5 in total

1.  Thoracic fluid content by electric bioimpedance correlates with respiratory distress in newborns.

Authors:  G Paviotti; A De Cunto; V Moressa; C Bettiol; S Demarini
Journal:  J Perinatol       Date:  2017-07-27       Impact factor: 2.521

2.  Tools for assessing lung fluid in neonates with respiratory distress.

Authors:  So Jin Yoon; Jung Ho Han; Kee Hyun Cho; Joonsik Park; Soon Min Lee; Min Soo Park
Journal:  BMC Pediatr       Date:  2022-06-20       Impact factor: 2.567

3.  Thoracic Fluid Content (TFC) Measurement Using Impedance Cardiography Predicts Outcomes in Critically Ill Children.

Authors:  Lydia Sumbel; Aanchal Wats; Mohammed Salameh; Elumalai Appachi; Utpal Bhalala
Journal:  Front Pediatr       Date:  2021-02-25       Impact factor: 3.418

4.  Thoracic fluid content: a novel parameter for predicting failed weaning from mechanical ventilation.

Authors:  Shymaa Fathy; Ahmed M Hasanin; Mohamed Raafat; Maha M A Mostafa; Ahmed M Fetouh; Mohamed Elsayed; Esraa M Badr; Hanan M Kamal; Ahmed Z Fouad
Journal:  J Intensive Care       Date:  2020-03-05

5.  Non-invasive Cardiac Output Monitoring and Assessment of Fluid Responsiveness in Children With Shock in the Emergency Department.

Authors:  Pranali Awadhare; Radha Patel; Tracy McCallin; Kiran Mainali; Kelly Jackson; Hannah Starke; Utpal Bhalala
Journal:  Front Pediatr       Date:  2022-04-07       Impact factor: 3.569

  5 in total