Literature DB >> 33710630

Advancements in capacitance-to-digital converter-based C4 D technology for detection in capillary electrophoresis using amplified excitation voltages and comparison to classical and open-source C4 Ds.

Hannes Georg Graf1, Benjamin Maximilian Rudisch1, Johanna Manegold1, Carolin Huhn1.   

Abstract

This work introduces new hardware configurations for a capacitively coupled contactless conductivity detector (C4 D) based on capacitance-to-digital conversion (CDC) technology for CE. The aim was to improve sensitivity, handling, price, and portability of CDC-based C4 D detectors (CDCD) to reach LODs similar to classic C4 Ds with more sophisticated electric circuits. To achieve this, a systematic study on the CDCDs was carried out including a direct comparison to already established C4 D setups. Instrumental setups differing in electrode lengths, measurement modes, and amplification of excitation voltages were investigated to achieve LODs for alkali metal ions of 4 to 12 μM, similar to LODs obtained by classic C4 D setups. Lowest LODs were achieved for a setup with two 10 mm electrodes at a distance of 0.2 mm and an excitation voltage of 24 V. The detection head was exceptionally lightweight with only 2.6 g and covered only 20 mm of the capillary on total. This allowed the use of multiple detectors along the separation path to enable spatial tracking of analytes during separation. The entirely battery-powered detector assembly weighs less than 200 g, and the data are transmitted wirelessly for possible portable applications. The freely accessible hardware and software were optimized for fully automated measurements with real time data plotting and allowed handling multidetector setups. The new developments were applied to quantify the potassium salt of glyphosate in its herbicide formulation.
© 2021 Wiley-VCH GmbH.

Entities:  

Keywords:  Automated measurements; Capacitance-to-digital conversion; Capacitively coupled contactless conductivity detection; Glyphosate formulation analysis; Multidetector setup

Mesh:

Substances:

Year:  2021        PMID: 33710630     DOI: 10.1002/elps.202000394

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  1 in total

1.  [Determination of two quaternary ammonium salts in disinfector by portable capillary electrophoresis device based on smartphone].

Authors:  Yuanyu Wang; Ruihua Zhang; Qiang Zhang; Chengxi Cao; Liuyin Fan; Weiwen Liu
Journal:  Se Pu       Date:  2021-11
  1 in total