Jiao Wang1, Shuai Li1, Weiqiang Chen2, Yue Chen1, Zekun Pang1, Jianming Li1. 1. Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin Medical University Clinical Cardiovascular Institute, Tianjin, China. 2. Department of Cardiology, TEDA International Cardiovascular Hospital, Tianjin Medical University Clinical Cardiovascular Institute, Tianjin, China.
Abstract
BACKGROUND: Myocardial blood flow (MBF) quantitation with cadmium-zinc-telluride (CZT) dynamic single-photon emission computed tomography (SPECT) is being increasingly investigated toward clinical utilization. METHODS: In this prospective study, forty-nine patients with suspected or known coronary artery disease (CAD) underwent a rest/adenosine triphosphate (ATP) stress dynamic and routine gated myocardial perfusion imaging (MPI) by CZT SPECT and then received coronary angiography (CAG). Quantitative diagnosis from the dynamic SPECT and a flow diagram was automatically obtained by the dedicated software and compared with the result of semi-quantitative analysis with gated MPI using the angiographic stenosis as the reference standard. RESULTS: When stenosis ≥50% was considered at the participant level, the sensitivity (SN), specificity (SP), positive predictive value (PPV), negative predictive value (NPV) and accuracy (AC) of the quantitative diagnosis were higher than semi-quantitative method as (84.4% vs. 65.6%, 88.2% vs. 70.6%, 93.1% vs. 80.8%, 75.0% vs. 52.2%, 85.7% vs. 67.3%) (all P<0.05). The receiver operating characteristic (ROC) curve analysis generated the optimal critical value as 1.86 and 1.61 mL/min/g for stress MBF (sMBF) and MFR, respectively. The diagnosis performance of the quantitative diagnosis was higher than semi-quantitative method as (78.9% vs. 68.4%, 63.3% vs. 60.0%, 57.7% vs. 52.0%, 82.6% vs. 75.0%, 69.4% vs. 63.3%) for the criteria of ≥75% stenosis on CAG (all P<0.05) with optimal critical values as 1.71 and 1.15 mL/min/g. There was no significant difference between sMBF and MFR. CONCLUSIONS: The diagnostic efficiency by using the quantitative method of CZT dynamic SPECT imaging is superior to traditional semi-quantitative gated MPI for the diagnosis of CAD, which improved the diagnostic specificity and accuracy when the critical was stenosis ≥50%. 2021 Cardiovascular Diagnosis and Therapy. All rights reserved.
BACKGROUND: Myocardial blood flow (MBF) quantitation with cadmium-zinc-telluride (CZT) dynamic single-photon emission computed tomography (SPECT) is being increasingly investigated toward clinical utilization. METHODS: In this prospective study, forty-nine patients with suspected or known coronary artery disease (CAD) underwent a rest/adenosine triphosphate (ATP) stress dynamic and routine gated myocardial perfusion imaging (MPI) by CZT SPECT and then received coronary angiography (CAG). Quantitative diagnosis from the dynamic SPECT and a flow diagram was automatically obtained by the dedicated software and compared with the result of semi-quantitative analysis with gated MPI using the angiographic stenosis as the reference standard. RESULTS: When stenosis ≥50% was considered at the participant level, the sensitivity (SN), specificity (SP), positive predictive value (PPV), negative predictive value (NPV) and accuracy (AC) of the quantitative diagnosis were higher than semi-quantitative method as (84.4% vs. 65.6%, 88.2% vs. 70.6%, 93.1% vs. 80.8%, 75.0% vs. 52.2%, 85.7% vs. 67.3%) (all P<0.05). The receiver operating characteristic (ROC) curve analysis generated the optimal critical value as 1.86 and 1.61 mL/min/g for stress MBF (sMBF) and MFR, respectively. The diagnosis performance of the quantitative diagnosis was higher than semi-quantitative method as (78.9% vs. 68.4%, 63.3% vs. 60.0%, 57.7% vs. 52.0%, 82.6% vs. 75.0%, 69.4% vs. 63.3%) for the criteria of ≥75% stenosis on CAG (all P<0.05) with optimal critical values as 1.71 and 1.15 mL/min/g. There was no significant difference between sMBF and MFR. CONCLUSIONS: The diagnostic efficiency by using the quantitative method of CZT dynamic SPECT imaging is superior to traditional semi-quantitative gated MPI for the diagnosis of CAD, which improved the diagnostic specificity and accuracy when the critical was stenosis ≥50%. 2021 Cardiovascular Diagnosis and Therapy. All rights reserved.
Authors: Venkatesh L Murthy; Masanao Naya; Courtney R Foster; Jon Hainer; Mariya Gaber; Gilda Di Carli; Ron Blankstein; Sharmila Dorbala; Arkadiusz Sitek; Michael J Pencina; Marcelo F Di Carli Journal: Circulation Date: 2011-10-17 Impact factor: 29.690
Authors: Daniel S Berman; Xingping Kang; Piotr J Slomka; James Gerlach; Ling de Yang; Sean W Hayes; John D Friedman; Louise E J Thomson; Guido Germano Journal: J Nucl Cardiol Date: 2007-07 Impact factor: 5.952
Authors: Jelena R Ghadri; Aju P Pazhenkottil; Rene N Nkoulou; Robert Goetti; Ronny R Buechel; Lars Husmann; Bernhard A Herzog; Mathias Wolfrum; Christophe A Wyss; Christian Templin; Philipp A Kaufmann Journal: Heart Date: 2011-04-12 Impact factor: 5.994
Authors: Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells Journal: J Nucl Cardiol Date: 2018-10 Impact factor: 5.952