Literature DB >> 11251778

Physical properties of resinous cements: an in vitro study.

R C Fraga1, L R Luca-Fraga, L A Pimenta.   

Abstract

The flow rate capacity, hydrolytic degradation and radiopacity of three resin-based cements were tested and compared with zinc phosphate cement, when used in accordance with the manufacturer's instructions. There are no significant differences among the cements with regard to the flow rate. The zinc phosphate cement showed superior hydrolytic degradation compared with the other cements tested. The cements presented different radiopacities and the zinc phosphate cement was the most radiopaque. The results suggest that the development of resin-based materials associated with adhesive procedures can increase the effectiveness of indirect restorations.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11251778     DOI: 10.1046/j.1365-2842.2000.00657.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs.

Authors:  Carlos José Soares; Fernanda Ribeiro Santana; Rodrigo Borges Fonseca; Luis Roberto Marcondes Martins; Francisco Haiter Neto
Journal:  Clin Oral Investig       Date:  2007-06-28       Impact factor: 3.573

2.  Comparative study of the radiopacity of resin cements used in aesthetic dentistry.

Authors:  Raquel Montes-Fariza; Manuel Monterde-Hernández; Cristina Cabanillas-Casabella; Antonio Pallares-Sabater
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

3.  Evaluation of radiopacities of CAD/CAM restorative materials and resin cements by digital radiography.

Authors:  Zerrin Unal Erzurumlu; Cennet Elcin Sagirkaya; Kerem Erzurumlu
Journal:  Clin Oral Investig       Date:  2021-03-11       Impact factor: 3.606

4.  Radiopacity evaluation of contemporary luting cements by digitization of images.

Authors:  José Maurício Dos Santos Nunes Reis; Erica Gouveia Jorge; João Gustavo Rabelo Ribeiro; Ligia Antunes Pereira Pinelli; Filipe de Oliveira Abi-Rached; Mário Tanomaru-Filho
Journal:  ISRN Dent       Date:  2012-09-13

5.  Film thickness and flow properties of resin-based cements at different temperatures.

Authors:  R Bagheri
Journal:  J Dent (Shiraz)       Date:  2013-06

6.  Optical density and chemical composition of microfilled and microhybrid composite resins.

Authors:  Ana Paula Braun; Clarissa Grassi Soares; Helena Glüer Carracho; Nilza Pereira da Costa; Elaine Bauer Veeck
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

7.  Radiopacity of contemporary luting cements using conventional and digital radiography.

Authors:  Seo-Young An; Chang-Hyeon An; Karp-Sik Choi; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2018-06-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.