Literature DB >> 3370399

Treadmill protocols for determination of maximum oxygen uptake in runners.

T R McConnell1, B A Clark.   

Abstract

Four testing protocols were completed by each of 10 runners using a common speed for protocols 1 and 2 (P1 and P2), each runner's training pace for protocol 3 (P3) and a speed selected manually by the runner for protocol 4 (P4). Stages were increased by 2.5% grade every 2 min for each protocol except for P1, which had 1 min stages. There were no significant differences in maximum oxygen uptake (VO2 max) between protocols (P1, 65.0 +/- 5.6 ml.kg-1 min-1; P2, 64.5 +/- 5.3 ml.kg-1 min-1; P3, 66.2 +/- 3.9 ml.kg-1 min-1; P4, 64.7 +/- 5.8 ml.kg-1 min-1). Treadmill time was significantly less for P1 than for the other protocols. The rate of perceived exertion obtained at maximal exercise during P1 was less than that obtained during the other three protocols. Heart rate was significantly lower (P less than 0.05) at any level of submaximal VO2 during P3 than during the other protocols. We recommend a testing protocol using speeds approximating the runner's training pace and 1 min stages. This may result in lower perception of difficulty and HR throughout the test and shorter testing times.

Entities:  

Mesh:

Year:  1988        PMID: 3370399      PMCID: PMC1478508          DOI: 10.1136/bjsm.22.1.3

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  10 in total

1.  Maximal oxygen uptake during treadmill walking and running at various speeds.

Authors:  B A Stamford
Journal:  J Appl Physiol       Date:  1975-09       Impact factor: 3.531

2.  Maximal oxygen intake as an objective measure of cardio-respiratory performance.

Authors:  H L TAYLOR; E BUSKIRK; A HENSCHEL
Journal:  J Appl Physiol       Date:  1955-07       Impact factor: 3.531

3.  A comparative analysis of four protocols for maximal treadmill stress testing.

Authors:  M L Pollock; R L Bohannon; K H Cooper; J J Ayres; A Ward; S R White; A C Linnerud
Journal:  Am Heart J       Date:  1976-07       Impact factor: 4.749

4.  Submaximal and maximal working capacity of elite distance runners. Part I: Cardiorespiratory aspects.

Authors:  M L Pollock
Journal:  Ann N Y Acad Sci       Date:  1977       Impact factor: 5.691

5.  An evaluation of a treadmill work test.

Authors:  T M Gibson; M H Harrison; R M Wellicome
Journal:  Br J Sports Med       Date:  1979-04       Impact factor: 13.800

6.  Perceived exertion as an indicator of somatic stress.

Authors:  G Borg
Journal:  Scand J Rehabil Med       Date:  1970

Review 7.  Psychogenic factors and exercise metabolism: a review.

Authors:  W P Morgan
Journal:  Med Sci Sports Exerc       Date:  1985-06       Impact factor: 5.411

8.  Maximum oxygen uptake utilising different treadmill protocols.

Authors:  B Davies; A Daggett; P Jakeman; J Mulhall
Journal:  Br J Sports Med       Date:  1984-06       Impact factor: 13.800

9.  Maximal oxygen uptake: its measurement, application, and limitations.

Authors:  M H Harrison; G A Brown; L A Cochrane
Journal:  Aviat Space Environ Med       Date:  1980-10

10.  Blood lactate concentration following maximum exercise in trained subjects.

Authors:  G C Gass; S Rogers; R Mitchell
Journal:  Br J Sports Med       Date:  1981-09       Impact factor: 13.800

  10 in total
  5 in total

1.  Salivary estradiol, interleukin-6 production, and the relationship to substrate metabolism during exercise in females.

Authors:  Stephen J Ives; Mark Blegen; Mary A Coughlin; Jan Redmond; Tracey Matthews; Vincent Paolone
Journal:  Eur J Appl Physiol       Date:  2011-01-04       Impact factor: 3.078

Review 2.  Challenging a dogma of exercise physiology: does an incremental exercise test for valid VO 2 max determination really need to last between 8 and 12 minutes?

Authors:  Adrian W Midgley; David J Bentley; Hans Luttikholt; Lars R McNaughton; Gregoire P Millet
Journal:  Sports Med       Date:  2008       Impact factor: 11.136

3.  Long maximal incremental tests accurately assess aerobic fitness in class II and III obese men.

Authors:  Stefano Lanzi; Franco Codecasa; Mauro Cornacchia; Sabrina Maestrini; Paolo Capodaglio; Amelia Brunani; Paolo Fanari; Alberto Salvadori; Davide Malatesta
Journal:  PLoS One       Date:  2015-04-13       Impact factor: 3.240

4.  Investigation of cardiopulmonary exercise testing using a dynamic leg press and comparison with a cycle ergometer.

Authors:  Farouk Chrif; Tobias Nef; Kenneth J Hunt
Journal:  BMC Sports Sci Med Rehabil       Date:  2018-02-15

5.  The Impact of Wrist Percooling on Physiological and Perceptual Responses during a Running Time Trial Performance in the Heat.

Authors:  Kelsey Denby; Ronald Caruso; Emily Schlicht; Stephen J Ives
Journal:  Int J Environ Res Public Health       Date:  2020-10-17       Impact factor: 3.390

  5 in total