| Literature DB >> 33681483 |
Alison Ranger1, Alex Dunlop1, Alex Grimwood1, Emily Durie1, Ellen Donovan1, Jo Havilland1, Emma Harris1, Helen McNair1, Anna M Kirby1.
Abstract
BACKGROUND: Deep-inspiration breath-hold (DIBH) reduces radiation dose to the heart in patients undergoing locoregional breast radiotherapy. In the context of tangential irradiation of the breast/ chest wall, a voluntary breath hold (vDIBH) technique has been shown to be as reproducible as a machine-assisted breath hold technique using the active breathing co-ordinator (ABC™, Elekta, Crawley, UK, ABC_DIBH). This study compares set-up reproducibility for vDIBH versus ABC_DIBH in patients undergoing volumetric-modulated arc radiotherapy (VMAT) for breast cancer, both with and without wax bolus.Entities:
Keywords: Breast radiotherapy; Heart sparing; Internal mammary chain; VMAT; Voluntary breath hold
Year: 2021 PMID: 33681483 PMCID: PMC7918266 DOI: 10.1016/j.ctro.2021.02.003
Source DB: PubMed Journal: Clin Transl Radiat Oncol ISSN: 2405-6308
Mean daily chest wall displacement on CBCT as compared to planning CT in three directions (mm) for each patient over 15 fractions for VMAT (ABC_DIBH) versus VMAT(vDIBH).
| Direction | ABC_DIBH Mean (mm) (SD) | vDIBH Mean (mm) (SD) | Mean of differences (mm) (SD) | 95% confidence interval of mean differences | P value (2 sided) |
|---|---|---|---|---|---|
| Right-Left (R-L) | 0.0 (6.4) | −0.1 (5.1) | −0.1 (1.3) | −1.7–1.5 | 0.9 |
| Superior-Inferior (S-I) | −1.2 (4.1) | −0.9 (3.3) | 0.3 (2.2) | −1.0–1.6 | 0.6 |
| Anterior-Posterior (A-P) | −1.3 (2.1) | −1.5 (1.9) | −0.2 (0.2) | −1.1–0.8 | 0.7 |
Patient characteristics at baseline.
| Characteristic | ABC start N = 9 | vDIBH start n = 7 |
|---|---|---|
| Median age (range)- years | 47 (28–60) | 37 (30–67) |
| Surgery | ||
| Mastectomy | 9 | 6 |
| WLE | 0 | 1 |
| Wax | ||
| Yes | 5 | 4 |
| No | 4 | 3 |
| Nodal status | ||
| N1 | 3 | 1 |
| N2 | 2 | 2 |
| N3 | 4 | 4 |
| Laterality | ||
| Left | 8 | 6 |
| Right | 1 | 1 |
Fig. 1a–c: The HeartSpare laser – a small laser is attached to a ball mounted grip which rotates on top of an extendable tripod. This is attached to the treatment couch using suction pads. The laser shines cross hairs on the patients’ chest in free breathing (1b) and breath hold (1c). The position of the cross hairs overlying a mark placed in breath hold (as defined according to pre-treatment instructions) identifies the patient is in the correct breath hold.
Fig. 2Image of a right sided breast cancer patient with wax bolus in position in voluntary breath hold.
Population mean displacement (MD), systematic (∑) and random () set-up errors for chest wall displacement on CBCT as compared to planning CT in three directions for VMAT(ABC_DIBH) versus VMAT(vDIBH).
| Direction | ABC_DIBH (mm) | vDIBH (mm) | |
|---|---|---|---|
| Right-left (R-L) | MD | 0.0 | 0.4 |
| ∑ | 6.4 | 4.9 | |
| 1.7 | 2.2 | ||
| Superior-inferior (S-I) | MD | 0.9 | 0.7 |
| ∑ | 4.1 | 3.3 | |
| 2.6 | 2.7 | ||
| Anterior-posterior (A-P) | MD | −1.4 | −1.5 |
| ∑ | 2.1 | 2.1 | |
| 1.8 | 2.2 | ||
Dose statistics for target volumes and organs at risk for VMAT(vDIBH) compared to VMAT(ABC_DIBH).
| Volume | VMAT (vDIBH) Mean (SD) | VMAT (ABC_DIBH) Mean (SD) | P value |
|---|---|---|---|
| PTV_WB (V 38.05 Gy) | 97.4 (2.3) | 97.3 (2.7) | 0.9 |
| PTV_Nodes (V 36.05 Gy) | 95.3 (5.7) | 96.5 (3.8) | 0.3 |
| PTV_IMC (V 36.05 Gy) | 92.7 (7.0) | 91.3 (8.2) | 0.3 |
| MHD (Gy) | 4.2 (1.3) | 4.4 (1.3) | 0.1 |
| V 17 Gy (%) | 33.8 (1.2) | 33.7 (1.6) | 0.8 |