Literature DB >> 33676433

Zygomatic implant penetration to the central portion of orbit: a case report.

Luan Mavriqi1, Felice Lorusso2, Roberto Conte3, Biagio Rapone3, Antonio Scarano4,5.   

Abstract

BACKGROUND: Zygomatic implants have been proposed in literature for atrophic maxillary fixed oral rehabilitations. The aim of the present research was to evaluate, by a clinical and tomography assessment, a surgical complication of a zygomatic implant penetration to the orbit. CASE <br> PRESENTATION: A 56 year-old female patient was visited for pain and swelling in the left orbit after a zygomatic implant protocol. The orbit invasion of the zygomatic implant screw was confirmed by the CBCT scan. The patient was treated for surgical implant removal and the peri- and post-operative symptoms were assessed. No neurological complications were reported at the follow-up. The ocular motility and the visual acuity were well maintained. No purulent secretion or inflammatory evidence were reported in the post-operative healing phases. <br> CONCLUSION: The penetration of the orbit during a zygomatic implant positioning is a surgical complication that could compromise the sight and movements of the eye. In the present case report, a zygomatic implant removal resulted in an uneventful healing phase with recovery of the eye functions.

Entities:  

Keywords:  Case report; Fixed prosthesis; Maxillary atrophy; Zygomatic implants

Mesh:

Year:  2021        PMID: 33676433      PMCID: PMC7936463          DOI: 10.1186/s12886-021-01846-1

Source DB:  PubMed          Journal:  BMC Ophthalmol        ISSN: 1471-2415            Impact factor:   2.209


  25 in total

1.  Sinus slot technique for simplification and improved orientation of zygomaticus dental implants: a technical note.

Authors:  J P Stella; M R Warner
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Nov-Dec       Impact factor: 2.804

2.  Biomechanical Behavior of the Dental Implant Macrodesign.

Authors:  Camila Lima de Andrade; Marco Aurélio Carvalho; Dimorvan Bordin; Wander José da Silva; Altair Antoninha Del Bel Cury; Bruno Salles Sotto-Maior
Journal:  Int J Oral Maxillofac Implants       Date:  2017 Mar/Apr       Impact factor: 2.804

3.  Measurement of the zygomatic bone and pilot hole technique for safer insertion of zygomaticus implants.

Authors:  N Takamaru; H Nagai; G Ohe; T Tamatani; K Sumida; S Kitamura; Y Miyamoto
Journal:  Int J Oral Maxillofac Surg       Date:  2015-09-26       Impact factor: 2.789

4.  Satisfaction grade assessment of patients treated with zygomatic implants with self-tapping apex and machined body.

Authors:  A Scarano; R Conte; G Murmura; F Lorusso; A H Harrath
Journal:  J Biol Regul Homeost Agents       Date:  2019 Sep-Oct       Impact factor: 1.711

5.  Retrospective Analysis of Zygomatic Implants for Maxillary Prosthetic Rehabilitation.

Authors:  Mustafa Yalçın; Serhat Can; Mert Akbaş; Gühan Dergin; Hasan Garip; Barış Altuğ Aydil; Altan Varol
Journal:  Int J Oral Maxillofac Implants       Date:  2020 Jul/Aug       Impact factor: 2.804

6.  A proposed classification for zygomatic implant patient based on the zygoma anatomy guided approach (ZAGA): a cross-sectional survey.

Authors:  Carlos Aparicio
Journal:  Eur J Oral Implantol       Date:  2011       Impact factor: 3.123

Review 7.  Rehabilitation of atrophic posterior maxilla with zygomatic implants: review.

Authors:  Eugenia Candel-Martí; Celia Carrillo-García; David Peñarrocha-Oltra; Maria Peñarrocha-Diago
Journal:  J Oral Implantol       Date:  2011-02-18       Impact factor: 1.779

8.  Removal torque values of titanium implants inserted into bone defects filled with hydroxyapatite: a histologic and histomorphometric analysis in rabbit.

Authors:  A Scarano; F Carinci; C Mangano; A Quaranta; A Piattelli
Journal:  Int J Immunopathol Pharmacol       Date:  2007 Jan-Mar       Impact factor: 3.219

9.  Evaluation of patients undergoing placement of zygomatic implants using sinus slot technique.

Authors:  P P T Araújo; S A Sousa; V B S Diniz; P P Gomes; J S P da Silva; A R Germano
Journal:  Int J Implant Dent       Date:  2016-01-13

10.  Augmented Hummelsheim procedure for paralytic strabismus.

Authors:  S E Brooks; S E Olitsky; G deB Ribeiro
Journal:  J Pediatr Ophthalmol Strabismus       Date:  2000 Jul-Aug       Impact factor: 1.402

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.