Literature DB >> 33670136

Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies.

Sigmar Schnutenhaus1,2, Cornelia Edelmann1, Anne Knipper1, Ralph G Luthardt2.   

Abstract

The aim of this systematic review and meta-analysis is to analyze the accuracy of implant placement using computer-assisted dynamic navigation procedures. An electronic literature search was carried out, supplemented by a manual search. The literature search was completed in June 2020. The results of in vitro and clinical studies were recorded separately from each other. For inclusion in the review, the studies had to examine at least the prosthetically relevant parameters for angle deviation, as well as global deviation or lateral deviation at the platform of the implant. Sixteen of 320 articles were included in the investigation: nine in vitro and seven clinical studies. The meta-analysis showed values of 4.1° for the clinical studies (95% CI, 3.12-5.10) and 3.7° for the in vitro studies (95% CI, 2.31-5.10) in terms of the angle deviation. The global deviation at the implant apex of the implant was 1.00 mm for the clinical studies (95% CI, 0.83-1.16) and 0.91 mm for the in vitro studies (95% CI, 0.60-1.12). These values indicate no significant difference between the clinical and in vitro studies. The results of this systematic review show a clinical accuracy of dynamic computer-assisted navigation that is comparable to that of static navigation. However, the dynamic navigation systems show a great heterogeneity that must be taken into account. Moreover, currently there are few clinical data available. Therefore, further investigations into the practicability of dynamic navigation seem necessary.

Entities:  

Keywords:  accuracy; computer-aided surgery; computer-assisted surgery; dental implantation; dental implants; dynamic navigation; prostheses and implants

Year:  2021        PMID: 33670136     DOI: 10.3390/jcm10040704

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  3 in total

1.  Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial.

Authors:  Cornelia Edelmann; Martin Wetzel; Anne Knipper; Ralph G Luthardt; Sigmar Schnutenhaus
Journal:  J Clin Med       Date:  2021-04-21       Impact factor: 4.241

2.  Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph
Journal:  Int J Implant Dent       Date:  2021-04-26

3.  Accuracy of Computer-Assisted Dynamic Navigation as a Function of Different Intraoral Reference Systems: An In Vitro Study.

Authors:  Sigmar Schnutenhaus; Anne Knipper; Martin Wetzel; Cornelia Edelmann; Ralph Luthardt
Journal:  Int J Environ Res Public Health       Date:  2021-03-21       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.