Literature DB >> 3364826

Continuous emergency department monitoring of arterial saturation in adult patients with respiratory distress.

J Jones1, D Heiselman, L Cannon, R Gradisek.   

Abstract

Continuous measurement of arterial oxygen saturation (SaO2) using pulse oximetry has become a common monitoring and management technique in critically ill hospitalized patients. To determine the impact of SaO2 monitoring on emergency patient management, we conducted a prospective uncontrolled clinical trial on 40 adult patients presenting to the emergency department with acute respiratory illness, such as emphysema, asthma, or pulmonary edema. Recorded data included hemograms, arterial blood gases, subsequent therapy, and response to treatment. Additionally, the "early warning" capability of SaO2 monitoring was analyzed by recording the severity and outcome of hypoxemic events during treatment. Mean duration of usage for the 40 oximeters in the ED was 1.8 hours; all probes functioned reliably over a wide range of systolic pressures (80 to 206 mm Hg), heart rates (40 to 180 beats per minute), and hematocrits (20% to 58%). There was good correlation between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and saturations derived from measured arterial PaO2 (r = 0.94). The device detected several otherwise unrecognized drops in arterial saturation that were confirmed by laboratory analysis. Other clinical situations in which the pulse oximeter was found useful in the ED are reviewed. We conclude that continuous measurement of SaO2 can improve the monitoring of ED patients, increase the precision of therapy, detect hypoxemia during intubation, suctioning, and other treatments, and detect clinically unsuspected changes in arterial oxygenation.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3364826     DOI: 10.1016/s0196-0644(88)80237-3

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  8 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 2.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 3.  Noninvasive blood gas monitoring: a review for use in the adult critical care unit. Technology Subcommittee of the Working Group on Critical Care, Ontario Ministry of Health.

Authors: 
Journal:  CMAJ       Date:  1992-03-01       Impact factor: 8.262

4.  Guidelines for diagnosis and management of bronchial asthma: Joint ICS/NCCP (I) recommendations.

Authors:  Ritesh Agarwal; Sahajal Dhooria; Ashutosh Nath Aggarwal; Venkata N Maturu; Inderpaul S Sehgal; Valliappan Muthu; Kuruswamy T Prasad; Lakshmikant B Yenge; Navneet Singh; Digambar Behera; Surinder K Jindal; Dheeraj Gupta; Thanagakunam Balamugesh; Ashish Bhalla; Dhruva Chaudhry; Sunil K Chhabra; Ramesh Chokhani; Vishal Chopra; Devendra S Dadhwal; George D'Souza; Mandeep Garg; Shailendra N Gaur; Bharat Gopal; Aloke G Ghoshal; Randeep Guleria; Krishna B Gupta; Indranil Haldar; Sanjay Jain; Nirmal K Jain; Vikram K Jain; Ashok K Janmeja; Surya Kant; Surender Kashyap; Gopi C Khilnani; Jai Kishan; Raj Kumar; Parvaiz A Koul; Ashok Mahashur; Amit K Mandal; Samir Malhotra; Sabir Mohammed; Prasanta R Mohapatra; Dharmesh Patel; Rajendra Prasad; Pallab Ray; Jai K Samaria; Potsangbam Sarat Singh; Honey Sawhney; Nusrat Shafiq; Navneet Sharma; Updesh Pal S Sidhu; Rupak Singla; Jagdish C Suri; Deepak Talwar; Subhash Varma
Journal:  Lung India       Date:  2015-04

5.  The role of pulse oximetry in the accident and emergency department.

Authors:  M A Lambert; J Crinnion
Journal:  Arch Emerg Med       Date:  1989-09

6.  Pulse oximetry: a "which" hunt?

Authors:  M K Sykes
Journal:  J Clin Monit       Date:  1989-04

7.  Oxygen saturation in adults with acute asthma.

Authors:  R Hardern
Journal:  J Accid Emerg Med       Date:  1996-01

8.  Errors in 14 pulse oximeters during profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh; S O Koh
Journal:  J Clin Monit       Date:  1989-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.