| Literature DB >> 33645920 |
Ivan R Fasulkov1, Manol Karadaev1, Nasko Vasilev1, Kalin Hristov2, Ivan Fedev3.
Abstract
The aim of the present study was to determine the parameters characterising the blood flow velocity in the fetal heart and aorta in goats by Doppler ultrasonography. Twenty-four Bulgarian White milk goats, aged 4-6 years, weighing 45-51 kg were used in the study. Doppler ultrasound measurements of the blood flow velocity in fetal heart were done at the end of first, second and third trimesters of pregnancy, and in the fetal aorta - at the end of the second and third trimesters of pregnancy. Ultrasound investigations were carried out by transabdominal approach with linear and convex transducers, with frequency 8.0 MHz. Blood flow parameters that included maximum and minimum systolic velocity, end-diastolic velocity, pulsatility index, resistance index and systolic/diastolic ratio were measured by spectral Doppler ultrasonography. The results showed that the highest maximum systolic velocity in the fetal heart was observed at the end of the first pregnancy trimester. Statistically significantly (p < 0.05) lower values of this parameter were registered in the second and third pregnancy trimesters. A similar tendency was observed for minimum systolic velocity, end-diastolic velocity and systolic/diastolic ratio. The pulsatility index and resistance index had similar values for the three studied periods. Examination of the fetal aorta showed statistically significant differences (p < 0.05) of minimum systolic velocity, end-diastolic velocity, pulsatility and resistance index in the third, compared with the second trimester of pregnancy. The analysis of the results suggested that Doppler ultrasonography can be used to monitor fetal blood flow changes during the various stages of pregnancy.Entities:
Keywords: Doppler; aorta; fetal heart; goats; ultrasonography
Year: 2021 PMID: 33645920 PMCID: PMC8294397 DOI: 10.1002/vms3.463
Source DB: PubMed Journal: Vet Med Sci ISSN: 2053-1095
FIGURE 1Colour Doppler ultrasonography of the fetal heart (a) and fetal aorta (b) in the 90th day of pregnancy in a goat
FIGURE 2Colour Doppler ultrasonography of the fetal heart (a) and fetal aorta (b) in the 133th day of pregnancy in a goat
FIGURE 3Continious‐wave spectral Doppler of the fetal heart (a) and aorta (b) in a goat
Doppler measurements (mean ± SD) of the parameters, characterising blood flow velocity in the fetal heart in goats (n = 24)
| Doppler indices | Pregnancy trimester | ||
|---|---|---|---|
| First | Second | Third | |
| Maximum systolic velocity (cm/s) | 63.34 ± 6.2 | 31.2 ± 9.6 | 21.89 ± 8.1 |
| Minimum systolic velocity (cm/s) | 23.27 ± 7.3 | 17.33 ± 3.7 | 12.17 ± 4.3 |
| End‐diastolic velocity (cm/s) | 20.21 ± 2.9 | 11.91 ± 3.9 | 8.3 ± 2.7 |
| Pulsatility index | 1.85 ± 0.15 | 1.10 ± 0.16 | 1.8 ± 0.2 |
| Resistance index | 0.68 ± 0.04 | 0.62 ± 0.04 | 0.65 ± 0.05 |
| Systolic/Diastolic ratio | 3.13 ± 0.07 | 2.62 ± 0.18 | 1.82 ± 0.16 |
Statistically significant differences versus first trimester of pregnancy at p < 0.05.
Doppler measurements (mean ± SD) of the parameters, characterising blood flow velocity in the fetal aorta in goats (n = 24)
| Doppler indices | Pregnancy trimester | |
|---|---|---|
| Second | Third | |
| Maximum systolic velocity (cm/s) | 12.62 ± 5.6 | 15.2 ± 2.6 |
| Minimum systolic velocity (cm/s) | 5.13 ± 1.7 | 12.0 ± 1.7 |
| End‐diastolic velocity (cm/s) | 6.67 ± 2.9 | 9.05 ± 1.9 |
| Pulsatility index | 1.14 ± 0.16 | 0.68 ± 0.12 |
| Resistance index | 0.47 ± 0.03 | 0.4 ± 0.1 |
| Systolic/Diastolic ratio | 1.89 ± 0.29 | 1.66 ± 0.2 |
Statistically significant differences between second and third trimester of pregnancy at p < 0.05.