Epsilon wave detected by an Apple Watch Series 5 in a patient with biventricular arrhythmogenic cardiomyopathy.

Eva Gutiérrez-Ortiz1, Juan Carlos Gómez-Polo1, David Vivas1, Isidre Vilacosta1.   

Abstract

Entities:  

Year:  2021        PMID: 33644665      PMCID: PMC7897555          DOI: 10.1093/ehjcr/ytab019

Source DB:  PubMed          Journal:  Eur Heart J Case Rep        ISSN: 2514-2119


× No keyword cloud information.
A 32-year-old man with a family history of sudden cardiac death due to arrhythmogenic cardiomyopathy (ACM) was admitted following a recovered ventricular fibrillation cardiac arrest . A family genetic study had detected that the patient carried a mutation on the desmoplaquin gene. Transthoracic echocardiography revealed a moderately dilated right ventricle with distal hypertrabeculation and decreased systolic function. The left ventricle was also dilated and showed impaired global systolic function. A conventional 12‐lead electrocardiogram (ECG) was performed showing sinus rhythm, a slight deflection at the end of the QRS in V1–V2, and T-wave inversion in lateral leads (). A conventional 12-lead electrocardiogram showing sinus rhythm, a slight deflection at the end of the QRS in V1–V2, and T-wave inversion in lateral leads. In addition to standard ECG, quasistandard precordial leads were obtained with an Apple Watch Series 5, displaying intraventricular conduction delay, a low amplitude small deflection between the terminal portion of QRS complex, and the onset of the T wave in all precordial leads, as well as T-wave inversion in lateral leads (, arrow). An Epsilon wave (arrow) in Apple Watch quasistandard precordial leads. This small deflection corresponds to an epsilon wave representing a post-excitation phenomenon of the myocytes in both ventricles. The Apple Watch registers precordial leads using an electrode on the right arm as negative pole, instead of using the classical Wilson’s central terminal pole. Additionally, the output signal filter is higher (511 Hz) when compared with the conventional ECG. Despite technical differences, the resulting tracing is similar to the conventional one. In conclusion, the Apple Watch can detect ECG pathological changes like epsilon waves thus contributing to the diagnostic of ACM.

Supplementary material

Supplementary material is available at European Heart Journal - Case Reports online. Consent: The authors confirm that written consent for submission and publication of this case report including images and associated text has been obtained from the patient in line with COPE guidance. Conflict of interest: None declared. Funding: None declared.
  2 in total

1.  Standard and Precordial Leads Obtained With an Apple Watch.

Authors:  Miguel Ángel Cobos Gil
Journal:  Ann Intern Med       Date:  2019-11-26       Impact factor: 25.391

2.  Desmoplakin Cardiomyopathy, a Fibrotic and Inflammatory Form of Cardiomyopathy Distinct From Typical Dilated or Arrhythmogenic Right Ventricular Cardiomyopathy.

Authors:  Eric D Smith; Neal K Lakdawala; Nikolaos Papoutsidakis; Gregory Aubert; Andrea Mazzanti; Anthony C McCanta; Prachi P Agarwal; Patricia Arscott; Lisa M Dellefave-Castillo; Esther E Vorovich; Kavitha Nutakki; Lisa D Wilsbacher; Silvia G Priori; Daniel L Jacoby; Elizabeth M McNally; Adam S Helms
Journal:  Circulation       Date:  2020-05-06       Impact factor: 29.690

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.