Literature DB >> 33632145

A novel fluorescent cardiac imaging system for preclinical intraoperative angiography.

Sara Mashalchi1, Sara Pahlavan2, Marjaneh Hejazi3,4.   

Abstract

BACKGROUND: Intraoperative coronary angiography can tremendously reduce early coronary bypass graft failures. Fluorescent cardiac imaging provides an advanced method for intraoperative observation and real-time quantitation of blood flow with high resolution.
METHODS: We devised a system comprised of an LED light source, special filters, lenses and a detector for preclinical coronary artery angiography. The optical setup was implemented by using two achromatic doublet lenses, two positive meniscus lenses, a band-pass filter, a pinhole and a CCD sensor. The setup was optimized by Zemax software. Optical design was further challenged to obtain more parallel light beams, less diffusion and higher resolutions to levels as small as arterioles. Ex vivo rat hearts were prepared and coronary arteries were retrogradely perfused by indocyanine green (ICG). Video angiography was employed to assess blood flow and plot time-dependent fluorescence intensity curve (TIC). Quantitation of blood flow was performed by calculating either the gradient of TIC or area under curve. The correlation between blood flow and each calculated parameters was assessed and used to evaluate the quality of flow.
RESULTS: High-resolution images of flow in coronary arteries were obtained as precise as 62 µm vessel diameter, by our custom-made ICG angiography system. The gradient of TIC was 3.4-6.3 s-1, while the area under curve indicated 712-1282 s values which ultimately gained correlation coefficients of 0.9938 and 0.9951 with relative blood flow, respectively.
CONCLUSION: The present ICG angiography system may facilitate evaluation of blood flow in animal studies of myocardial infarction and coronary artery grafts intraoperatively.

Entities:  

Keywords:  Fluorescent cardiac imaging; Indocyanine green; Intraoperative angiography; Rodents

Mesh:

Year:  2021        PMID: 33632145      PMCID: PMC7905866          DOI: 10.1186/s12880-021-00562-y

Source DB:  PubMed          Journal:  BMC Med Imaging        ISSN: 1471-2342            Impact factor:   1.930


  1 in total

1.  Near-infrared fluorescence coronary angiography: a new noninvasive technology for intraoperative graft patency control.

Authors:  Christian Detter; Detlef Russ; Andre Iffland; Sabine Wipper; Marc O Schurr; Herman Reichenspurner; Gerd Buess; Bruno Reichart
Journal:  Heart Surg Forum       Date:  2002       Impact factor: 0.676

  1 in total
  1 in total

1.  Optical Coupling Efficiency of a Coupler with Double-Combined Collimating Lenses and Thermally Expanded Core Fibers.

Authors:  Qi He; Zhengang Zhao; Xiaoda Ye; Chuan Luo; Dacheng Zhang; Sifei Wang; Xiaoping Xu
Journal:  Micromachines (Basel)       Date:  2022-02-18       Impact factor: 2.891

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.