BACKGROUND: Intraoperative graft patency verification is of major clinical importance for quality control after coronary artery bypass grafting (CABG), especially if surgery is performed on the beating heart. This is one of the first reports of fluorescence coronary angiography (FCA) using the dye indocyanine green (ICG), a noninvasive technology for direct visualization of coronary arteries, bypass grafts, and myocardial perfusion.
METHODS: Twenty-three domestic pigs (weight, 45-72 kg) underwent FCA of the left anterior descending coronary artery (LAD). In the first group (n = 6 pigs), FCA was used to visualize the native coronary vessels and myocardial perfusion. In the second group (n = 8 pigs), 14 stenoses of various degrees and 4 total vessel occlusions were created by snares on different segments of the LAD, and FCA was used to visualize the effects of these obstructions. In the third group (n = 9 pigs), a coronary bypass procedure on the beating heart was performed by a left internal mammary artery or a human saphenous vein graft to the LAD, and FCA was used to visualize graft patency. Three pigs were removed from the study because of ventricular fibrillation. ICG was intravenously applied, and the heart was illuminated with near-infrared light emitted by laser diodes. The fluorescence emission was detected by an adapted charge-coupled device camera system. The images were displayed in real time on a high-resolution monitor. Subsequently, images obtained with FCA were compared to those obtained with coronary angiography (n = 10 pigs).
RESULTS: In all cases, high-quality FCA images of coronary arteries and myocardial perfusion were obtained. All stenoses resulted in an impairment of the myocardial perfusion visualized by FCA. Occlusion of the LAD or the diagonal branch resulted in a total perfusion defect of the corresponding anterior myocardial wall with immediate reperfusion after releasing the snare. In 5 cases a patent bypass graft with an apparent homogenous perfusion of the corresponding myocardium was detectable. In one procedure, FCA images indicated total occlusion of the bypass graft and a total perfusion deficit in the distal LAD region. Correlation between FCA and coronary angiography in detection of stenoses and graft patency was excellent.
CONCLUSION: With the fluorescence technique using ICG, visualization of blood flow in coronary vessels and bypass grafts, as well as of myocardial perfusion, is feasible. FCA is a highly sensitive and reproducible method and an excellent technique for intraoperative quality control in CABG.

Entities:  

Mesh:

Year:  2002        PMID: 12538119

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  15 in total

1.  Quantitative assessment technique of HyperEye medical system angiography for coronary artery bypass grafting.

Authors:  Masaki Yamamoto; Hideaki Nishimori; Takemi Handa; Takashi Fukutomi; Kazuki Kihara; Miwa Tashiro; Takayuki Sato; Kazumasa Orihashi
Journal:  Surg Today       Date:  2016-06-28       Impact factor: 2.549

2.  Qualitative angiographic and quantitative myocardial perfusion assessment using fluorescent cardiac imaging during graded coronary artery bypass stenosis.

Authors:  Christian Detter; Detlef Russ; Jan Felix Kersten; Hermann Reichenspurner; Sabine Wipper
Journal:  Int J Cardiovasc Imaging       Date:  2017-07-15       Impact factor: 2.357

Review 3.  Techniques for intraoperative graft assessment in coronary artery bypass surgery.

Authors:  Lucas B Ohmes; Antonino Di Franco; Gabriele Di Giammarco; Carlo Maria Rosati; Christopher Lau; Leonard N Girardi; Massimo Massetti; Mario Gaudino
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

4.  Efficacy of intraoperative HyperEye Medical System angiography for coronary artery bypass grafting.

Authors:  Masaki Yamamoto; Kazumasa Orihashi; Hideaki Nishimori; Takemi Handa; Nobuo Kondo; Takashi Fukutomi; Takayuki Sato
Journal:  Surg Today       Date:  2014-08-28       Impact factor: 2.549

5.  Role of indo-cyanine green (ICG) fluorescence in laparoscopic adrenalectomy: a retrospective review of 55 Cases.

Authors:  Eham Arora; Ajay Bhandarwar; Amol Wagh; Saurabh Gandhi; Chintan Patel; Shubham Gupta; Gagandeep Talwar; Jasmine Agarwal; Jai Rathore; Soumya Chatnalkar
Journal:  Surg Endosc       Date:  2018-06-25       Impact factor: 4.584

6.  Influence of residual coronary flow on bypass graft flow for graft assessment using near-infrared fluorescence angiography.

Authors:  Masaki Yamamoto; Hitoshi Ninomiya; Kohei Miyashita; Miwa Tashiro; Kazumasa Orihashi; Keiji Inoue; Takayuki Sato; Kazuhiro Hanazaki
Journal:  Surg Today       Date:  2019-07-25       Impact factor: 2.549

7.  Distinction of non-ischemia inducing versus ischemia inducing coronary stenosis by fluorescent cardiac imaging.

Authors:  Sabine Wipper; Beate Reiter; Detlef Russ; Fabian Hahnel; Jan-Felix Kersten; Tilo Kölbel; Hermann Reichenspurner; Christian Detter
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-25       Impact factor: 2.357

8.  Intraoperative near-infrared fluorescence imaging and spectroscopy identifies residual tumor cells in wounds.

Authors:  David Holt; Ashwin B Parthasarathy; Olugbenga Okusanya; Jane Keating; Ollin Venegas; Charuhas Deshpande; Giorgos Karakousis; Brian Madajewski; Amy Durham; Shuming Nie; Arjun G Yodh; Sunil Singhal
Journal:  J Biomed Opt       Date:  2015-07       Impact factor: 3.170

9.  Image-guided liver mapping using fluorescence navigation system with indocyanine green for anatomical hepatic resection.

Authors:  Takeshi Aoki; Daisuke Yasuda; Yoshinori Shimizu; Masanori Odaira; Takashi Niiya; Tomokazu Kusano; Keitaro Mitamura; Ken Hayashi; Noriyuki Murai; Tomotake Koizumi; Hirohisa Kato; Yuta Enami; Mitsuharu Miwa; Mitsuo Kusano
Journal:  World J Surg       Date:  2008-08       Impact factor: 3.352

10.  Usefulness of blood supply visualization by indocyanine green fluorescence for reconstruction during esophagectomy.

Authors:  Yutaka Shimada; Tomoyuki Okumura; Takuya Nagata; Shigeaki Sawada; Koshi Matsui; Ryota Hori; Isaku Yoshioka; Toru Yoshida; Ryusuke Osada; Kazuhiro Tsukada
Journal:  Esophagus       Date:  2011-09-10       Impact factor: 4.230

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.