Literature DB >> 3362978

Reliability of measurements of concentric and eccentric isokinetic loading.

T J Tredinnick1, P W Duncan.   

Abstract

The purpose of this study was to assess the reliability of a method for testing peak torque and work output of the knee extensor muscle during concentric and eccentric loading at three velocities of exercise (60 degrees, 120 degrees, and 180 degrees/sec). Fourteen healthy men (23-32 years of age) performed exercises of the quadriceps femoris muscles during concentric and eccentric loading, with a five-second pause between each contraction. Three different tests were performed on different occasions. The first exercise session was a practice session, and the next two sessions were established to collect data in a test-retest format. Peak torque and work were measured for the two testing sessions. The results of this study demonstrated that with a very specific protocol, the reliability of concentric peak torque and work measurements was excellent at 60 degrees and 120 degrees/sec and good at 180 degrees/sec. In contrast, reliability of eccentric peak torque and work measurements was good at 120 degrees and 180 degrees/sec but low at 60 degrees/sec.

Entities:  

Mesh:

Year:  1988        PMID: 3362978     DOI: 10.1093/ptj/68.5.656

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  21 in total

1.  Muscle activation during maximal voluntary eccentric and concentric knee extension.

Authors:  S H Westing; A G Cresswell; A Thorstensson
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

Review 2.  Physiological adaptations to velocity-controlled resistance training.

Authors:  G J Bell; H A Wenger
Journal:  Sports Med       Date:  1992-04       Impact factor: 11.136

3.  Posterior rotator cuff strengthening using theraband(r) in a functional diagonal pattern in collegiate baseball pitchers.

Authors:  P A Page; J Lamberth; B Abadie; R Boling; R Collins; R Linton
Journal:  J Athl Train       Date:  1993       Impact factor: 2.860

4.  Interrater reliability of isokinetic measures of knee flexion and extension.

Authors:  D R Keskula; J S Dowling; V L Davis; P W Finley; D L Dell'omo
Journal:  J Athl Train       Date:  1995-06       Impact factor: 2.860

5.  Comparison of N-k table offset angles with the human knee flexor torque curve.

Authors:  D J Laplaca; D R Keskula; K I Heinrichs; D H Perrin
Journal:  J Athl Train       Date:  1993       Impact factor: 2.860

6.  The Reliability Of Three Isokinetic Knee-extension Angle-specific Torques.

Authors:  B L Arnold; D H Perrin; E V Hellwig
Journal:  J Athl Train       Date:  1993       Impact factor: 2.860

7.  The reliability and validity of two new tests of maximum lifting capacity.

Authors:  J Alpert; L Matheson; W Beam; V Mooney
Journal:  J Occup Rehabil       Date:  1991-03

8.  Eccentric and concentric isokinetic knee flexion and extension: a reliability study using the Cybex 6000 dynamometer.

Authors:  R C Li; Y Wu; N Maffulli; K M Chan; J L Chan
Journal:  Br J Sports Med       Date:  1996-06       Impact factor: 13.800

Review 9.  Biomechanics and muscle function during gait.

Authors:  R Brunner; E Rutz
Journal:  J Child Orthop       Date:  2013-09-15       Impact factor: 1.548

10.  Improving strength and postural control in young skiers: whole-body vibration versus equivalent resistance training.

Authors:  Nele N Mahieu; Erik Witvrouw; Danny Van de Voorde; Diny Michilsens; Valérie Arbyn; Wouter Van den Broecke
Journal:  J Athl Train       Date:  2006 Jul-Sep       Impact factor: 2.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.