| Literature DB >> 33629056 |
Mara Elena Rusnac1, Cristina Gasparik2, Ada Gabriela Delean1, Alexandra Iulia Aghiorghiesei2, Diana Dudea2.
Abstract
BACKGROUND AND AIMS: To assess the color, translucency and masking properties of novel flowable giomers.Entities:
Keywords: giomers; masking capacity; optical properties; spectroradiometer; translucency
Year: 2021 PMID: 33629056 PMCID: PMC7880075 DOI: 10.15386/mpr-1924
Source DB: PubMed Journal: Med Pharm Rep ISSN: 2602-0807
Composition and characteristics of flowable giomers studied (from manufacturers’ instructions - Shofu Dental Corporation, Japan).
| Name | Consistency | Composition | Code |
|---|---|---|---|
| Beautifil flow Plus X F00 | Minimal flow | Bis-GMA, TEGDMA, Bis-MPEPP, S-PRG filler based on fluoroboroaluminosilicate glass, polymerization initiator, pigments and others | F00 |
| Beautifil flow F02 | Low flow | Bis-GMA, TEGDMA, S-PRG filler based on fluoroboroaluminosilicate glass, polymerization initiator, pigments and others | F02 |
| Beautifil flow Plus X F03 | Low flow | Bis-GMA, TEGDMA, Bis-MPEPP, S-PRG filler based on fluoroboroaluminosilicate glass, polymerization initiator, pigments and others | F03 |
Bis-GMA = bisphenol A diglycidildimethacrylate; TEGDMA = triethylene glycol dimethacrylate; Bis-MPEPP = Bisphenol A polyethoxy methacrylate; S-PRG = Surface pre-reacted glass-ionomer.
CIEL*a*b coordinates of each background, averaged from three measurements.
| White | Black | C3 | A2 | A3 | |
|---|---|---|---|---|---|
| 97.14 | 24.60 | 59.81 | 74.29 | 70.94 | |
| −0.24 | −0.03 | 5.18 | 4.70 | 7.24 | |
| 3.05 | −2.06 | 17.73 | 18.26 | 23.93 |
Average CIE L*a*b* values and standard deviations of tested giomers measured over a white background.
| A2 | A3 | |||||
|---|---|---|---|---|---|---|
| L | a | b | L | a | b | |
| 86.16 (±0.86)a | 4.39 (±0.24)b | 24.83 (±0.58) | 84.24 (±0.58) | 6.31 (±0.34) d | 32.54 (±1.57) f | |
| 86.39 (±0.63)a | 4.28 (±0.3)b | 25.47 (±0.82)c | 83.34 (±0.3) | 6.46 (±0.22)d,e | 30.88 (±0.5)g | |
| 86.40 (±0.63)a | 4.28 (±0.29)b | 25.47 (±0.83)c | 84.19 (±0.4) | 6.47 (±0.22)e | 30.81 (±6.31)f,g | |
Same superscript letter in the same column indicate no significant difference (p>0.05).
Figure 1Color differences (ΔE00) between pairs of giomers evaluated over white background (50:50% PT represent the visual perceptibility threshold for color differences).
Average translucency (RTP00) values and standard deviations of giomer samples.
| A2 | A3 | |
|---|---|---|
| 30.34 (±0.88) | 29.64 (±1.64)b | |
| 31.37 (±0.94)a | 30.79 (±1.02)c | |
| 31.11 (±1.15)a | 30.1 (±1.26)b,c |
Same superscript letter in the same column indicate no significant difference (p>0.05).
Figure 2Differences in translucency (ΔRTP00) between giomers over white background (50:50% TPT00 represent the visual perceptibility threshold for differences in translucency).
Masking capacity of the tested giomers expressed as a color difference (ΔE00) between the sample measured over A2 or A3 background and the sample measured over C3 background.
| A2 | A3 | |
|---|---|---|
| 6.28 (±0.53) | 5.35 (±0.48)a | |
| 5.92 (±0.38) | 5.48 (±0.59)a | |
| 5.63 (±0.57) | 4.89 (±0.35) |
Same superscript letter in the same column indicate no significant difference (p>0.05).