Literature DB >> 33619852

Commissioning of a Versa HDTM linear accelerator for three commercial treatment planning systems.

Wolfram U Laub1, Brandon Merz2, Monica Kishore2.   

Abstract

In a mixed-vendor radiation oncology environment, it is advantageous if the department's treatment planning system (TPS) supports the linear accelerators of different vendors. In this publication beam data collection and modeling for the Versa HD linear accelerator in Monaco, Pinnacle, and Eclipse are discussed. In each TPS static field, Intensity-Modulated Radiation Therapy (IMRT) step and shoot, and Volumetric-Modulated Arc Therapy (VMAT) plans for flattened and flattening-filter free photon beams of all available energies were evaluated for field sizes >3 × 3. To compare passing rates, identical beam model validation plans were calculated in each TPS. Eclipse, Monaco, and Pinnacle beam models passed validation measurements in homogeneous materials for a variety of treatment fields, including static, IMRT, and VMAT. In the case of Eclipse, the "dosimetric leaf gap" parameter was found to be critical for passing rates of VMAT plans. The source size parameter plays an important role as well for small fields. In the case of Pinnacle the multileaf collimator offset table needed to be optimized for better VMAT QA results. Each of the investigated treatment planning systems met the criteria to be used clinically in conjunction with Elekta Versa HD linear accelerators. It can be of great advantage to have the option to operate a TPS and linear accelerator from different vendors, as decisions surrounding linear accelerator or TPS purchases are very complicated and not just limited to technical considerations.
© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  Eclipse; Monaco; Pinnacle; Versa HD; beam modeling; linear accelerator commissioning

Mesh:

Year:  2021        PMID: 33619852      PMCID: PMC7984463          DOI: 10.1002/acm2.13180

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  8 in total

1.  Comparison of dynamic and step-and-shoot intensity-modulated radiation therapy planning and delivery.

Authors:  Parham Alaei; Patrick D Higgins; Randi Weaver; Nina Nguyen
Journal:  Med Dosim       Date:  2004       Impact factor: 1.482

2.  IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.

Authors:  Gary A Ezzell; Jay W Burmeister; Nesrin Dogan; Thomas J LoSasso; James G Mechalakos; Dimitris Mihailidis; Andrea Molineu; Jatinder R Palta; Chester R Ramsey; Bill J Salter; Jie Shi; Ping Xia; Ning J Yue; Ying Xiao
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  Accelerator beam data commissioning equipment and procedures: report of the TG-106 of the Therapy Physics Committee of the AAPM.

Authors:  Indra J Das; Chee-Wai Cheng; Ronald J Watts; Anders Ahnesjö; John Gibbons; X Allen Li; Jessica Lowenstein; Raj K Mitra; William E Simon; Timothy C Zhu
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

4.  Reference dataset of users' photon beam modeling parameters for the Eclipse, Pinnacle, and RayStation treatment planning systems.

Authors:  Mallory C Glenn; Christine B Peterson; David S Followill; Rebecca M Howell; Julianne M Pollard-Larkin; Stephen F Kry
Journal:  Med Phys       Date:  2019-11-15       Impact factor: 4.071

5.  Effect of beam profile measurement on arc therapy plan quality assurance: a case study.

Authors:  Leonard H Kim; Irina Malajovich; Meral L Reyhan; Jinyu Xue; Joo Han Park
Journal:  J Appl Clin Med Phys       Date:  2017-03-29       Impact factor: 2.102

6.  Agility MLC transmission optimization in the Monaco treatment planning system.

Authors:  Michael Roche; Robert Crane; Marcus Powers; Timothy Crabtree
Journal:  J Appl Clin Med Phys       Date:  2018-06-30       Impact factor: 2.102

7.  Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.

Authors:  You Zhang; Anh H Le; Zhen Tian; Zohaib Iqbal; Tsuicheng Chiu; Xuejun Gu; Andrei Pugachev; Robert Reynolds; Yang K Park; Mu-Han Lin; Strahinja Stojadinovic
Journal:  J Appl Clin Med Phys       Date:  2019-08-30       Impact factor: 2.102

8.  Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator.

Authors:  James L Bedford; Michael D R Thomas; Gregory Smyth
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.