Literature DB >> 33618018

Additively manufactured space-filling meta-implants.

H M A Kolken1, C P de Jonge2, T van der Sloten3, A Fontecha Garcia3, B Pouran4, K Willemsen4, H Weinans5, A A Zadpoor2.   

Abstract

The unprecedented properties of meta-biomaterials could pave the way for the development of life-lasting orthopedic implants. Here, we used non-auxetic meta-biomaterials to address the shortcomings of the current treatment options in acetabular revision surgery. Due to the severe bone deficiencies and poor bone quality, it can be very challenging to acquire adequate initial implant stability and long-term fixation. More advanced treatments, such as patient-specific implants, do guarantee the initial stability, but are formidably expensive and may eventually fail due to stress shielding. We, therefore, developed meta-implants furnished with a deformable porous outer layer. Upon implantation, this layer plastically deforms into the defects, thereby improving the initial stability and homogeneously stimulating the surrounding bone. We first studied the space-filling behavior of additively manufactured pure titanium lattices, based on six different unit cells, in a compression test complemented with full-field strain measurements. The diamond, body-centered cubic, and rhombic dodecahedron unit cells were eventually selected for the design of the deformable porous outer layer. Each design came in three different relative density profiles, namely maximum (MAX), functionally graded (FG), and minimum (MIN). After their compression in bone-mimicking molds with simulated acetabular defects, the space-filling behavior of the implants was evaluated using load-displacement curves, micro-CT images, and 3D reconstructions. The meta-implants with an FG diamond infill exhibited the most promising space-filling behavior. However, the required push-in forces exceed the impact forces currently applied in surgery. Future research should, therefore, focus on design optimization, to improve the space-filling behavior and to facilitate the implantation process for orthopedic surgeons. STATEMENT OF SIGNIFICANCE: Ideally, orthopedic implants would last for the entire lifetime of the patient. Unfortunately, they rarely do. Critically sized defects are a common sight in the revision of acetabular cups, and rather difficult to treat. The permanent deformation of lattice structures can be used to create shape-morphing implants that would fill up the defect site, and thereby restore the physiological loading conditions. Bending-dominated structures were incorporated in the porous outer layer of the space-filling meta-implants for their considerable lateral expansion in response to axial compression. A functionally graded density offered structural integrity at the joint while enhancing the deformability at the bone-implant interface. With the use of a more ductile metal, CP-Ti, these meta-implants could be deformed without strut failure.
Copyright © 2021 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Acetabular cup; Meta-biomaterials; Meta-implants; Non-auxetic; Shape-matching

Mesh:

Substances:

Year:  2021        PMID: 33618018     DOI: 10.1016/j.actbio.2021.02.020

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  4 in total

Review 1.  Additively manufactured metallic biomaterials.

Authors:  Elham Davoodi; Hossein Montazerian; Anooshe Sadat Mirhakimi; Masoud Zhianmanesh; Osezua Ibhadode; Shahriar Imani Shahabad; Reza Esmaeilizadeh; Einollah Sarikhani; Sahar Toorandaz; Shima A Sarabi; Rohollah Nasiri; Yangzhi Zhu; Javad Kadkhodapour; Bingbing Li; Ali Khademhosseini; Ehsan Toyserkani
Journal:  Bioact Mater       Date:  2021-12-30

2.  Biomechanical Effects of 3D-Printed Bioceramic Scaffolds With Porous Gradient Structures on the Regeneration of Alveolar Bone Defect: A Comprehensive Study.

Authors:  Zhuohui Yang; Chunjuan Wang; Hui Gao; Lurong Jia; Huan Zeng; Liwen Zheng; Chao Wang; Hongmei Zhang; Lizhen Wang; Jinlin Song; Yubo Fan
Journal:  Front Bioeng Biotechnol       Date:  2022-05-26

Review 3.  A Critical Review of the Design, Manufacture, and Evaluation of Bone Joint Replacements for Bone Repair.

Authors:  Yi Huo; Yongtao Lyu; Sergei Bosiakov; Feng Han
Journal:  Materials (Basel)       Date:  2021-12-26       Impact factor: 3.623

Review 4.  Additive Manufacturing of Biomaterials-Design Principles and Their Implementation.

Authors:  Mohammad J Mirzaali; Vahid Moosabeiki; Seyed Mohammad Rajaai; Jie Zhou; Amir A Zadpoor
Journal:  Materials (Basel)       Date:  2022-08-08       Impact factor: 3.748

  4 in total