Literature DB >> 33616945

Fatal sepsis associated with a storage container leak permitting platelet contamination with environmental bacteria after pathogen reduction.

Emmanuel A Fadeyi1, Stephen J Wagner2, Corinne Goldberg2, Thea Lu3, Pampee Young2, Peter W Bringmann3, Nathaniel M Meier4, Andrew M Namen4, Richard J Benjamin3, Elizabeth Palavecino1.   

Abstract

BACKGROUND: Pathogen reduction technology and enhanced bacterial culture screening promise to significantly reduce the risk of transfusion-associated septic reactions due to contaminated platelets. Recent reports suggest that these interventions lack efficacy for post-collection and processing contamination with environmental organisms if the storage bag integrity is compromised. CASE REPORT: We report a fatal septic transfusion reaction in a 63-year-old patient with chronic kidney and liver disease who received a pathogen reduced platelet transfusion in anticipation of surgery.
METHODS: The residual platelet concentrate was cultured, with the detected microorganisms undergoing 16S genotype sequencing. Separate pathogen reduction studies were performed on the recovered bacteria, including assessment for amotosalen photoproducts. The storage container was subjected to pressure testing and microscopic examination. Environmental culture screening was performed at the hospital.
RESULTS: Gram negative rods were detected in the platelet unit and cultures of both platelet component and the patient's blood grew Acinetobacter baumannii complex, Leclercia adecarboxylata and Staphylococcus saprophyticus. These strains were effectively inactivated with >7.2, 7.7, and >7.1 log10 kill, respectively. The platelet storage container revealed a leak visible only on pressure testing. Hospital environmental cultures were negative and the contamination source is unknown. A. baumannii complex and S. saprophyticus 16S genotyping sequences were identical to those implicated in a previously reported septic reaction.
CONCLUSION: Findings are compatible with post-processing environmental contamination of a pathogen reduced platelet concentrate via a non-visible, acquired storage container leak. Efforts are warranted to actively prevent damage to, and detect defects in, platelet storage containers, and to store and transport components in clean environments.
© 2020 AABB.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 33616945     DOI: 10.1111/trf.16210

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Acquired platelet storage container leaks and contamination with environmental bacteria: A preventable cause of bacterial sepsis.

Authors:  Richard R Gammon; Rita A Reik; Marc Stern; Ralph R Vassallo; Dan A Waxman; Pampee P Young; Richard J Benjamin
Journal:  Transfusion       Date:  2021-12-20       Impact factor: 3.337

2.  Economic implications of FDA platelet bacterial guidance compliance options: Comparison of single-step strategies.

Authors:  Katherine M Prioli; Ilze Abersone; Patricia M Kopko; Jay H Herman; Brian Custer; Laura T Pizzi
Journal:  Transfusion       Date:  2022-01-08       Impact factor: 3.337

3.  Evaluation of an improved rapid bacterial assay with untreated and pathogen-reduced platelets: Detection of Acinetobacter strains.

Authors:  David LaVerda; Lisa Shinefeld; Nancy Best; Johny Lisitu; Gary Tambolleo; Yli Remo Vallejo
Journal:  Transfusion       Date:  2021-05-27       Impact factor: 3.337

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.