Treatment planning comparison of volumetric modulated arc therapy with the trilogy and the Halcyon for bilateral breast cancer.

Tao Sun1, Xiutong Lin1, Guifang Zhang1, Qingtao Qiu1, Chengqiang Li1, Yong Yin2.   

Abstract

BACKGROUND: The Halcyon is a new machine from the Varian company. The purpose of this study was to evaluate the dosimetry of the Halcyon in treatment of bilateral breast cancer with volumetric modulated arc therapy.
METHODS: On CT images of 10 patients with bilateral breast cancer, four Halcyon plans with different setup fields were generated, and dosimetric comparisons using Bonferroni's multiple comparisons test were conducted among the four plans. Whole and partial arc plans on the Trilogy and the Halcyon, referred to as T-4arc, T-8arc, H-4arc and H-8arc, were designed. The prescription dose was 50 Gy in 2-Gy fractions. All plans were designed with the Eclipse version 15.5 treatment planning system. The dosimetric differences between whole and partial arc plans in the same accelerator were compared using the Mann-Whitney U test. The better Halcyon plan was selected for the further dosimetric comparison of the plan quality and delivery efficiency between the Trilogy and the Halcyon.
RESULTS: Halcyon plans with high-quality megavoltage cone beam CT setup fields increased the Dmean, D2 and V107 of the planning target volume (PTV) and the V5 and Dmean of the heart, left ventricle (LV) and lungs compared with other Halcyon setup plans. The mean dose and low dose volume of the heart, lungs and liver were significantly decreased in T-8arc plans compared to T-4arc plans. In terms of the V5, V20, V30, V40 and Dmean of the heart, the V20, V30, V40 and Dmean of the LV, the V30, V40, Dmax and Dmean of the left anterior descending artery (LAD), and the V5 and V40 of lungs, H-8arc was significantly higher than H-4arc (p < 0.05). Compared with the Trilogy's plans, the Halcyon's plans reduced the high-dose volume of the heart and LV but increased the mean dose of the heart. For the dose of the LAD and the V20 and V30 of lungs, there was no significant difference between the two accelerators. Compared with the Trilogy, plans on the Halcyon significantly increased the skin dose but also significantly reduced the delivery time.
CONCLUSION: For the Halcyon, the whole-arc plans have more dosimetric advantages than partial-arc plans in bilateral breast cancer radiotherapy. Although the mean dose of the heart and the skin dose are increased, the doses of the cardiac substructure and other OARs are comparable to the Trilogy, and the delivery time is significantly reduced.

Entities:  

Keywords:  Bilateral breast cancer; Dosimetry; Halcyon; Trilogy; Volumetric modulated arc therapy

Year:  2021        PMID: 33602267      PMCID: PMC7890882          DOI: 10.1186/s13014-021-01763-z

Source DB:  PubMed          Journal:  Radiat Oncol        ISSN: 1748-717X            Impact factor:   3.481


  37 in total

1.  A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

Authors:  I Paddick
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

2.  Spine stereotactic body radiotherapy utilizing cone-beam CT image-guidance with a robotic couch: intrafraction motion analysis accounting for all six degrees of freedom.

Authors:  Derek Hyde; Fiona Lochray; Renee Korol; Melanie Davidson; C Shun Wong; Lijun Ma; Arjun Sahgal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-01       Impact factor: 7.038

3.  Safety and benefit of using a virtual bolus during treatment planning for breast cancer treated with arc therapy.

Authors:  Marguerite Tyran; Agnes Tallet; Michel Resbeut; Marjorie Ferre; Veronique Favrel; Pierre Fau; Laurence Moureau-Zabotto; Julien Darreon; Laurence Gonzague; Ahcene Benkemouche; Leonel Varela-Cagetti; Naji Salem; Bertrand Farnault; Marie-Aimee Acquaviva; Hugues Mailleux
Journal:  J Appl Clin Med Phys       Date:  2018-06-30       Impact factor: 2.102

4.  Partial kilovoltage cone beam computed tomography, complete kilovoltage cone beam computed tomography, and electronic portal images for breast radiation therapy: A dose-comparison study.

Authors:  Houda Bahig; Étienne Roussin; Michael Yassa; Peter Vavassis; Céline Lemaire; Laurie Archambault; David H A Nguyen
Journal:  Pract Radiat Oncol       Date:  2015-03-29

5.  Deep inspiration breathhold for left-sided breast cancer patients with unfavorable cardiac anatomy requiring internal mammary nodal irradiation.

Authors:  Osama Mohamad; Jean Shiao; Bo Zhao; Karen Roach; Ezequiel Ramirez; Dat T Vo; Kimberly Thomas; Xuejun Gu; Ann Spangler; Kevin Albuquerque; Asal Rahimi
Journal:  Pract Radiat Oncol       Date:  2017-04-13

6.  Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation - A case study.

Authors:  Jan Seppälä; Janne Heikkilä; Kimmo Myllyoja; Kristiina Koskela
Journal:  Rep Pract Oncol Radiother       Date:  2015-06-15

Review 7.  Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10,801 women in 17 randomised trials.

Authors:  S Darby; P McGale; C Correa; C Taylor; R Arriagada; M Clarke; D Cutter; C Davies; M Ewertz; J Godwin; R Gray; L Pierce; T Whelan; Y Wang; R Peto
Journal:  Lancet       Date:  2011-10-19       Impact factor: 79.321

Review 8.  Deep Inspiration Breath Hold: Techniques and Advantages for Cardiac Sparing During Breast Cancer Irradiation.

Authors:  Carmen Bergom; Adam Currey; Nina Desai; An Tai; Jonathan B Strauss
Journal:  Front Oncol       Date:  2018-04-04       Impact factor: 6.244

9.  Characterization of the Megavoltage Cone-Beam Computed Tomography (MV-CBCT) System on HalcyonTM for IGRT: Image Quality Benchmark, Clinical Performance, and Organ Doses.

Authors:  Irina Malajovich; Boon-Keng Kevin Teo; Heather Petroccia; James M Metz; Lei Dong; Taoran Li
Journal:  Front Oncol       Date:  2019-06-12       Impact factor: 6.244

10.  Optical Surface Management System for Patient Positioning in Interfractional Breast Cancer Radiotherapy.

Authors:  Zhao Ma; Wei Zhang; Yi Su; Peiji Liu; Yinghua Pan; Gang Zhang; Yipeng Song
Journal:  Biomed Res Int       Date:  2018-01-09       Impact factor: 3.411

View more
  2 in total

1.  Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy.

Authors:  Kazutoshi Yokoyama; Hiromasa Kurosaki; Hajime Oyoshi; Kosei Miura; Nobuko Utsumi
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec

2.  Effect of the simulated half leaf width of a multileaf collimator on volumetric modulated arc therapy plan quality in hippocampal avoidance whole-brain radiotherapy.

Authors:  Ming-Hsien Li; Li-Jhen Chen; Chih-Chieh Chang; Jo-Ting Tsai; Jang-Chun Lin
Journal:  J Appl Clin Med Phys       Date:  2022-03-03       Impact factor: 2.243