Literature DB >> 33602211

The efficacy of convenient cleaning methods applicable for customized abutments: an in vitro study.

Sunjai Kim1, Changhun Choi2, Yunsu Cha3, Jae-Seung Chang4.   

Abstract

BACKGROUND: The demand for implant dentistry, which includes customized abutments, is increasing. A lot of pollutions are generated on the customized abutment surface following milling procedure. This study evaluated the surface topography and cleanliness of customized abutments after cleaning procedures, which are simply applicable in the dental clinic.
METHODS: Thirty computer-aided design and computer-aided manufacturing internal connection type titanium abutments were produced, milled, and randomly divided into 3 groups: steam cleaning (control group), chlorhexidine (CHX) scrubbing (test group 1), and ultrasonic cleaning with CHX solution, acetone, and ethyl alcohol (test group 2). Each group was evaluated using microscopic and microbial analysis.
RESULTS: Foreign bodies were observed on the abutment surfaces in control group and test group 1, but not in test group 2. Bacteria were observed on 40% of the agar plates following steam cleaning; most of the colonies consisted of Bacillus cereus and Staphylococcus warneri. Colony growth was absent following test group 1 and 2.
CONCLUSION: For customized abutments, cleaning with steam is ineffective. CHX scrubbing effectively eliminates only bacteria. Ultrasonic cleaning with CHX solution, acetone, and ethyl alcohol successfully removes both foreign bodies and bacteria. Thus, the ultrasonic cleaning method is conveniently applicable in the dental clinic for eliminating contamination of the customized abutment surface.

Entities:  

Keywords:  Bacteria; CAD/CAM; Chlorhexidine; Foreign bodies; Implants; Sterilization; Titanium

Year:  2021        PMID: 33602211      PMCID: PMC7890105          DOI: 10.1186/s12903-021-01436-z

Source DB:  PubMed          Journal:  BMC Oral Health        ISSN: 1472-6831            Impact factor:   2.757


  38 in total

1.  A bone quality-based implant system: first year of prosthetic loading.

Authors:  C E Misch; F Dietsh-Misch; J Hoar; G Beck; R Hazen; C M Misch
Journal:  J Oral Implantol       Date:  1999       Impact factor: 1.779

2.  Cleaning, Disinfection, and Sterilization Protocols Employed for Customized Implant Abutments: An International Survey of 100 Universities Worldwide.

Authors:  Luigi Canullo; Marco Tallarico; Stephen Chu; David Peñarrocha; Mutlu Özcan; Paolo Pesce
Journal:  Int J Oral Maxillofac Implants       Date:  2017-05-18       Impact factor: 2.804

3.  Interaction of chlorhexidine with smooth and rough types of titanium surfaces.

Authors:  Avital Kozlovsky; Zvi Artzi; Ofer Moses; Nurit Kamin-Belsky; Ronit Bar-Ness Greenstein
Journal:  J Periodontol       Date:  2006-07       Impact factor: 6.993

4.  Retention of chlorhexidine in the human oral cavity after mouth rinses.

Authors:  P Bonesvoll; P Lökken; G Rölla; P N Paus
Journal:  Arch Oral Biol       Date:  1974-03       Impact factor: 2.633

Review 5.  The value of ultrasonic cleaners in dental practice.

Authors:  E M Bentley
Journal:  Br Dent J       Date:  1994-07-23       Impact factor: 1.626

6.  Protective effects of COX-2 inhibitor on titanium-particle-induced inflammatory osteolysis via the down-regulation of RANK/RANKL.

Authors:  Dechun Geng; Haiqing Mao; Junhua Wang; Xuesong Zhu; Chen Huang; Liang Chen; Huilin Yang; Yaozeng Xu
Journal:  Acta Biomater       Date:  2011-05-11       Impact factor: 8.947

7.  Micrometer-sized titanium particles can induce potent Th2-type responses through TLR4-independent pathways.

Authors:  Pankaj K Mishra; Wenhui Wu; Cristina Rozo; Nadim J Hallab; Joseph Benevenia; William C Gause
Journal:  J Immunol       Date:  2011-11-16       Impact factor: 5.422

8.  Microscopical and microbiologic characterization of customized titanium abutments after different cleaning procedures.

Authors:  Luigi Canullo; Costanza Micarelli; Luigi Lembo-Fazio; Giuliano Iannello; Marco Clementini
Journal:  Clin Oral Implants Res       Date:  2012-12-05       Impact factor: 5.977

9.  Low dose metal particles can induce monocyte/macrophage survival.

Authors:  Derek C Lacey; Bernard De Kok; Felix I Clanchy; Mark J Bailey; Kathy Speed; David Haynes; Stephen E Graves; John A Hamilton
Journal:  J Orthop Res       Date:  2009-11       Impact factor: 3.494

10.  The influence of implant-abutment connection on the screw loosening and microleakage.

Authors:  Katsuhiro Tsuruta; Yasunori Ayukawa; Tatsuya Matsuzaki; Masafumi Kihara; Kiyoshi Koyano
Journal:  Int J Implant Dent       Date:  2018-04-09
View more
  1 in total

1.  The Effect of Disinfectants Absorption and Medical Decontamination on the Mechanical Performance of 3D-Printed ABS Parts.

Authors:  Diana Popescu; Florin Baciu; Catalin Gheorghe Amza; Cosmin Mihai Cotrut; Rodica Marinescu
Journal:  Polymers (Basel)       Date:  2021-12-03       Impact factor: 4.329

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.