| Literature DB >> 33587922 |
Ignacio Torres1, Sandrine Poujois1, Eliseo Albert1, Gabriela Álvarez1, Javier Colomina1, David Navarro2.
Abstract
Entities:
Year: 2021 PMID: 33587922 PMCID: PMC7879056 DOI: 10.1016/j.jinf.2021.02.010
Source DB: PubMed Journal: J Infect ISSN: 0163-4453 Impact factor: 6.072
Performance of the CLINITESTⓇ Rapid COVID-19 Antigen Test at point of care for detection of SARS-CoV-2 infection.
| Population group | RAD performance | |
|---|---|---|
| Sensitivity (95% CI) | Specificity (95% CI) | |
| Symptomatic patients with suspected COVID-19 | 80.2 (70.9–87.1) | 100% (95.8–100) |
| Asymptomatic close contacts of COVID-19 patients | 60.0 (40.7–76.6) | 100% (94.6–100) |
| All participants CT ≤20 (≥7.1 log10 copies/ml) | 100 (94,9–100) | – |
| All participants CT ≤25 (≥6.2 log10 copies/ml) | 95.5 (89–98.2) | – |
| All participants CT ≤30 (≥5.2 log10 copies/ml) | 94.6 (87.9–97.7) | – |
| All participants CT <33 (≥3.4 log10 copies/ml) | 75.9 (67.3–82.7) | – |
CI, confidence interval; CT, RT-PCR cycle threshold; RAD, rapid antigen assay.